A colorimetric and SERS-based LFIA for sensitive and simultaneous detection of three stroke biomarkers: An ultra-fast and sensitive point-of-care testing platform

被引:0
|
作者
Wang, Yutong [1 ]
Zhang, Qianchun [3 ]
Huang, Mengping [1 ]
Ai, Ganggang [1 ]
Liu, Xiaofeng [4 ]
Zhang, Yuqi [1 ]
Li, Ran [1 ]
Wu, Jie [2 ]
机构
[1] Yan An Univ, Coll Chem & Chem Engn, Natl Ctr Qual Supervis & Inspecti Oil & Gas Prod Y, Key Lab New Energy & New Funct Mat,Yan An Key Lab, Yan An 716000, Peoples R China
[2] Shenyang Med Coll, Liaoning Med Funct Food Profess Technol Innovat Ct, Sch Publ Hlth, Shenyang 110034, Peoples R China
[3] Xingyi Normal Univ Nationalities, Sch Biol & Chem, Key Lab Analyt Sci Food & Environm Pollut Qianxin, Xingyi 562400, Peoples R China
[4] Baise Univ, Guangxi Key Lab Urban Water Environm, Baise 533000, Peoples R China
基金
中国国家自然科学基金;
关键词
Colorimetric; SERS; LFIA; POCT; Ultra-fast; Simultaneous detection; HEART-FAILURE; IMMUNOASSAYS; MMP-9;
D O I
10.1016/j.talanta.2024.127166
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Stroke ranks as the second leading cause of disability and mortality globally. Biomarker detection represents a promising avenue for predicting disease severity and prognosis. The expression levels of metalloproteinase-9 (MMP-9), neuron-specific enolase (NSE), and N-terminal pro-brain natriuretic peptide (NT-pro BNP) in blood correlate with stroke severity. Hence, monitoring these biomarkers is crucial for stroke diagnosis and management. Point-of-care testing (POCT) offers on-site diagnostic capabilities, with lateral flow immunoassay (LFIA) being the most widely used method currently. However, traditional LFIA sensitivity requires enhancement. This study introduces an ultra-sensitive surface-enhanced Raman scattering-based lateral flow immunoassay (SERSbased LFIA) strip for simultaneous detection of the three stroke biomarkers using SERS immune tags. Bimetallic core-shell structured SERS immune tags leverage the advantages of two metals, ensuring stability and enhancing Raman signals through plasmon resonance. This development of a POCT based on SERS-based LFIA strips offers rapid, sensitive, and multiplex detection of stroke biomarkers. The limits of detection (LODs) for MMP-9, NSE, and NT-pro BNP were 0.00020 ng mL- 1, 0.00016 ng mL-1, and 0.00012 ng mL- 1, respectively. Furthermore, enzyme-linked immunosorbent assay (ELISA) validated the accuracy of SERS-based LFIA. Clinical sample analysis demonstrated consistency between outcomes obtained by SERS-based LFIA and ELISA. Thus, SERS-based LFIA presents a novel POCT approach for stroke diagnosis.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Versatile, reusable and highly sensitive SERS-based point-of-care testing microplatform for reliable ATP detection
    Chi, Jinxin
    Xie, Qian
    Huang, Guobin
    Xie, Shulun
    Lin, Xucong
    Huang, Guihua
    BIOSENSORS & BIOELECTRONICS, 2024, 265
  • [2] Preamplification-free ultra-fast and ultra-sensitive point-of-care testing via LwaCas13a
    Zeng, Wanting
    Chen, Wanping
    Liu, Yang
    Zhang, Ting
    Zhai, Chao
    Li, Wenqiang
    Wang, Longyu
    Zhang, Cheng
    Zeng, Qili
    Wang, Fei
    Ma, Lixin
    BIOSENSORS & BIOELECTRONICS, 2024, 259
  • [3] A sensitive SERS-based sandwich immunoassay platform for simultaneous multiple detection of foodborne pathogens without interference
    Bai, Xiangru
    Shen, Aiguo
    Hu, Jiming
    ANALYTICAL METHODS, 2020, 12 (40) : 4885 - 4891
  • [4] Highly Sensitive Fluorescence-based Lateral Flow Platform for Point-of-Care Detection of Biomarkers in Plasma
    Zhu, Meilin
    Obahiagbon, Uwadiae
    Anderson, Karen S.
    Christen, Jennifer Blain
    2017 IEEE-NIH HEALTHCARE INNOVATIONS AND POINT OF CARE TECHNOLOGIES (HI-POCT), 2017, : 249 - 252
  • [5] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    Biosensors and Bioelectronics, 2021, 168
  • [6] Portable and multiplexed lateral flow immunoassay reader based on SERS for highly sensitive point-of-care testing
    Xiao, Rui
    Lu, Luchun
    Rong, Zhen
    Wang, Chongwen
    Peng, Yongjin
    Wang, Feng
    Wang, Jinhai
    Sun, Meijie
    Dong, Jian
    Wang, Dongfeng
    Wang, Luanluan
    Sun, Nanxi
    Wang, Shengqi
    BIOSENSORS & BIOELECTRONICS, 2020, 168
  • [7] Bacterial metabolism-triggered-chemiluminescence-based point-of-care testing platform for sensitive detection and photothermal inactivation of Staphylococcus aureus
    Yu, Xinghui
    Ma, Yongqiang
    Liu, Siyuan
    Qi, Chunchun
    Zhang, Weiqi
    Xiang, Wen
    Li, Zhaoxian
    Yang, Kai
    Duan, Shaoxian
    Du, Xinrao
    Yu, Jian
    Xie, Yan
    Wang, Zicheng
    Jiang, Wentao
    Zhang, Li
    Lin, Xiaodong
    ANALYTICA CHIMICA ACTA, 2023, 1281
  • [8] A Conjugated Polymer-Based Portable Smartphone Platform for Sensitive and Point-Of-Care Detection of Monoamine Neurotransmitter
    Zehra, Nehal
    Malik, Akhtar H.
    Parui, Retwik
    Hussain, Sameer
    Krishnan Iyer, Parameswar
    CHEMISTRY-AN ASIAN JOURNAL, 2024, 19 (20)
  • [9] CRISPR/Cas12-Based Ultra-Sensitive and Specific Point-of-Care Detection of HBV
    Ding, Ronghua
    Long, Jinzhao
    Yuan, Mingzhu
    Zheng, Xue
    Shen, Yue
    Jin, Yuefei
    Yang, Haiyan
    Li, Hao
    Chen, Shuaiyin
    Duan, Guangcai
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2021, 22 (09)
  • [10] Point-of-care COVID-19 testing: colorimetric diagnosis using rapid and ultra-sensitive ramified rolling circle amplification
    Choi, Moon Hyeok
    Kumara, Guralamatta Siddappa Ravi
    Lee, Jaehyeon
    Seo, Young Jun
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (19) : 5907 - 5915