Experiment of the flow field at the outlet of impeller of axial-flow pump

被引:0
|
作者
Li, Zhong [1 ]
Yang, Minguan [1 ]
Wang, Chunlin [1 ]
机构
[1] School of Energy and Power Engineering, Jiangsu University, Zhenjiang 212013, China
关键词
Kinetics - Pumps - Axial flow - Velocity distribution - Probes - Flanges - Flow fields - Impellers - Kinetic energy;
D O I
暂无
中图分类号
学科分类号
摘要
The flow field at the outlet of impeller in the designed axial-flow pump was measured by using the five-hole probe. Three velocity components and circulation curves were obtained. The measured results show that the flow field at the outlet of impeller is a spiral movement. Under the optimum condition, the rotary kinetic energy occupies 34% of the total outlet kinetic energy and decreases with the increase of the flux. Accompanied by the small radial velocity, the axial velocity increases with the flow intensifying. The velocity circulation decrease from the hub to the flange, wherefore the more circular velocity at the flange and the less at the hub are needed. The 3-D velocity distribution of flow field can be measured accurately by the probe. This method has the merits of simple operation and well applicability.
引用
下载
收藏
页码:94 / 97
相关论文
共 50 条
  • [1] Numerical calculation of cavitating flow in impeller of axial-flow pump
    Yang M.
    Ji K.
    Li Z.
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2010, 41 (SUPPL. 1): : 10 - 14
  • [2] EXPERIMENTAL STUDY ON CAVITATING FLOW IN IMPELLER OF AXIAL-FLOW PUMP
    Li Zhong
    Yang Minguan
    Kang Can
    Gao Bo
    Ji Kai
    PROCEEDINGS OF THE ASME/JSME/KSME JOINT FLUIDS ENGINEERING CONFERENCE 2011, VOL 1, PTS A-D, 2012, : 381 - 386
  • [3] BEHAVIOR OF AIR BUBBLES IN AN AXIAL-FLOW PUMP IMPELLER
    MURAKAMI, M
    MINEMURA, K
    MECHANICAL ENGINEERING, 1983, 105 (07) : 96 - 96
  • [4] BEHAVIOR OF AIR BUBBLES IN AN AXIAL-FLOW PUMP IMPELLER
    MURAKAMI, M
    MINEMURA, K
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03): : 277 - 283
  • [5] Effect of the impeller blade outlet setting angle on the performance of the helical axial-flow multiphase pump
    Wang, Jiaqiong
    Hu, Chen
    Bai, Ling
    Agarwal, Ramesh
    Zhou, Ling
    FRONTIERS IN ENERGY RESEARCH, 2024, 12
  • [6] Effect of guide vane outlet angle on pump performance and impeller radial force in an axial-flow heart pump
    刘复飞
    Sang Xiaohu
    High Technology Letters, 2018, 24 (02) : 219 - 226
  • [7] Hydrodynamic optimization of the impeller and diffuser vane of an axial-flow pump
    Nguyen, Duc-Anh
    Ma, Sang-Bum
    Kim, Sung
    Kim, Jin-Hyuk
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (03) : 1263 - 1278
  • [8] Experimental investigation of meridional velocity and circulation in axial-flow impeller outlet
    Zhang, Desheng
    Li, Tongtong
    Shi, Weidong
    Zhang, Hua
    Zhang, Guangjian
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2012, 28 (07): : 73 - 77
  • [9] Hydrodynamic optimization of the impeller and diffuser vane of an axial-flow pump
    Duc-Anh Nguyen
    Sang-Bum Ma
    Sung Kim
    Jin-Hyuk Kim
    Journal of Mechanical Science and Technology, 2023, 37 : 1263 - 1278
  • [10] Simulation and experiment of flow field in axial-flow hydrocyclone
    Zhen-bo, Wang
    Yi, Ma
    You-hai, Jin
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (6A): : 603 - 610