Optimal scheduling of integrated energy system with coal-to-hydrogen and carbon capture power plant based on low-carbon demand response

被引:0
|
作者
Yang Z. [1 ]
Xing H. [1 ]
Jiang W. [2 ]
Wang H. [1 ]
Sun Y. [1 ]
Yan Z. [1 ]
机构
[1] College of Electrical Engineering, Shanghai University of Electric Power, Shanghai
[2] Jiaxing Power Supply Company of State Grid Zhejiang Electric Power Co., Ltd., Jiaxing
关键词
carbon capture power plant; coal-to-hydrogen; integrated energy system; low-carbon demand response; low-carbon economic scheduling; low-carbon hydrogen production;
D O I
10.16081/j.epae.202308029
中图分类号
学科分类号
摘要
In order to improve the low-carbon and economy of the integrated energy system, the optimal scheduling of integrated energy system considering the low-carbon demand response mechanism under the joint operation mode of coal-to-hydrogen and carbon capture power plant is proposed. The models of coal-to-hydrogen and oxygen-rich combustion carbon capture power plant are established, and the carbon storage tank and power-to-gas device are introduced to improve the carbon capture flexibility and reduce the oxygen and hydrogen production costs. The low-carbon demand response mechanism is introduced into the scheduling model of integrated energy system, and its emission reduction ability is analyzed. The low-carbon economic scheduling model of integrated energy system is established with the minimum operation cost as the objective function. The proposed strategy is verified by a numerical example, and the results show that the strategy can improve the consumption level of wind power, reduce the carbon emission of the whole system, and improve the system economy. © 2024 Electric Power Automation Equipment Press. All rights reserved.
引用
收藏
页码:25 / 32
页数:7
相关论文
共 18 条
  • [1] MENG Xiangyu, CHEN Mingyun, GU Alun, Et al., China’s hydrogen development strategy in the context of double carbon targets, Natural Gas Industry, 42, 4, pp. 156-179, (2022)
  • [2] LI Ziqiu, QIAO Ying, LU Zongxiang, Operation mode analysis and configuration optimization of offshore wind-hydrogen system, Automation of Electric Power Systems, 46, 8, pp. 104-112, (2022)
  • [3] YUAN Tiejiang, GAO Lingyu, XIE Yongsheng, Et al., Design and comprehensive evaluation of wind-thermal power coupling multi-energy system based on hydrogen energy, Electric Power Automation Equipment, 41, 10, pp. 227-233, (2021)
  • [4] YUAN Tiejiang, CAO Jilei, Capacity optimization allocation of wind hydrogen low-carbon energy system considering wind power-load uncertainty, High Voltage Engineering, 48, 6, pp. 2037-2044, (2022)
  • [5] CHEN Haipeng, CHEN Jindong, ZHANG Zhong, Et al., Low-carbon economic dispatching of power system considering capture energy consumption of carbon capture power plants with flexible operation mode, Electric Power Automation Equipment, 41, 9, pp. 133-139, (2021)
  • [6] LIU Zheyuan, XING Haijun, CHENG Haozhong, Et al., Bi-level optimal scheduling of integrated energy system considering carbon emission flow and demand response, High Voltage Engineering, 49, 1, pp. 169-178, (2023)
  • [7] CUI Yang, ZENG Peng, ZHONG Wuzhi, Et al., Low-carbon economic dispatch of electro-gas-thermal integrated energy system based on oxy-combustion technology, Proceedings of the CSEE, 41, 2, pp. 592-608, (2021)
  • [8] XU Jian, HU Jia, LIAO Siyang, Et al., Coordinated optimization of integrated energy system considering dynamic characteristics of network and integrated demand response, Automation of Electric Power Systems, 45, 12, pp. 40-48, (2021)
  • [9] LI Yaowang, ZHANG Ning, DU Ershun, Et al., Mechanism study and benefit analysis on power system low carbon demand response based on carbon emission flow, Proceedings of the CSEE, 42, 8, pp. 2830-2842, (2022)
  • [10] LI Guoqing, WANG Chong, LEI Shunbo, Et al., Bi-level optimal allocation of power system considering carbon capture technology, Electric Power Automation Equipment, 43, 1, pp. 25-31, (2023)