Isotope abundance ratios and isotopic composition of strontium in a biological sample were determined using MC-ICP-MS whereby zirconium was admixed with solutions of digested NIST SRM 987 and samples and used for mass bias correction with implementation of a combination of standard-sample-standard bracketing and internal normalization. In this manner; the certified value of 8.37861 for 88Sr/86Sr in SRM 987 was used for mass bias correction of 90Zr/91Zr in two adjacent spiked solutions of SRM 987. Their average was then used to calculate mass bias corrected Sr isotope ratios in the sample. An approximate 2.5-fold improvement in precision of determination of 87Sr/86Sr and 88Sr/ 86Sr was obtained compared to that based on only the standard-sample-standard bracketing technique; although close matching of Sr and Zr concentrations is required in the standard and sample. Absolute isotope ratios of 0.0564240 ± 0.0000042; 0.709362 ± 0.000013 and 8.38034 ± 0.00010 (1SD) and δx/86Sr-values of -2.228 ± 0.075; -1.377; ±; 0.018; and; 0.207; 0.012; (1SD); for; 84Sr/86Sr; 87Sr/86Sr; 88Sr/86Sr relative to SRM 987; respectively; were obtained characterizing a fish liver sample. In agreement with previous studies; evidence is presented for variation of 88Sr/86Sr in samples. Estimation of the measurement uncertainty confirmed that the major source of imprecision arises from the uncertainty in the certified value of 88Sr/86Sr in SRM 987 used for mass bias correction. © 2008 The Royal Society of Chemistry;
D O I
暂无
中图分类号
学科分类号
摘要
Journal article (JA)
引用
收藏
页码:1269 / 1274
相关论文
共 50 条
  • [1] Use of Zr for mass bias correction in strontium isotope ratio determinations using MC-ICP-MS
    Yang, Lu
    Peter, Charlotte
    Panne, Ulrich
    Sturgeon, Ralph E.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) : 1269 - 1274
  • [2] A Comparative Analysis of Mass Bias Correction Methods for Sr Isotope Ratio Determination by MC-ICP-MS
    Kasyanova, A., V
    Streletskaya, M., V
    Okuneva, T. G.
    Kiseleva, D., V
    VII INTERNATIONAL YOUNG RESEARCHERS' CONFERENCE - PHYSICS, TECHNOLOGY, INNOVATIONS (PTI-2020), 2020, 2313
  • [3] Stable isotope geochemistry of strontium using MC-ICP-MS
    Ohno, Takeshi
    Hirata, Takafumi
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2006, 70 (18) : A453 - A453
  • [4] Correction of mass fractionation for isotope dilution analysis by MC-ICP-MS
    Zhang, Le
    Ren, Zhong-Yuan
    Ma, Jin-Long
    Xia, Xiao-Ping
    GEOCHEMICAL JOURNAL, 2017, 51 (02) : 157 - 165
  • [5] Effective Correction of Mass Bias for Rhenium Measurements by MC-ICP-MS
    Poirier, Andre
    Doucelance, Regis
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2009, 33 (02) : 195 - 204
  • [6] Mass bias correction laws suitable for MC-ICP-MS measurement
    Galer, SJG
    Abouchami, W
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A542 - A542
  • [7] High throughput uranium isotope ratio analysis using MC-ICP-MS: Techniques to improve the mass bias stability.
    Bowen, IM
    Miller, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 220 : U7 - U8
  • [8] Plutonium and uranium isotope ratio measurement by MC-ICP-MS
    Taylor, RN
    Warneke, T
    Croudace, IW
    Milton, JA
    Warwick, PE
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2002, 66 (15A) : A766 - A766
  • [9] Quantification of stable strontium isotope variability in nature by MC-ICP-MS
    Nowell, G. M.
    Charlier, B. L. A.
    Pearson, D. G.
    Burton, K. W.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2007, 71 (15) : A725 - A725
  • [10] Ion Exchange Chromatography and Mass Bias Correction for Accurate and Precise Zn Isotope Ratio Measurements in Environmental Reference Materials by MC-ICP-MS
    Araujo, Daniel F.
    Boaventura, Geraldo R.
    Viers, Jerome
    Mulholland, Daniel S.
    Weiss, Dominik
    Araujo, Debora
    Lima, Barbara
    Ruiz, Izabel
    Machado, Wilson
    Babinski, Marly
    Dantas, Elton
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2017, 28 (02) : 225 - 235