Electrochemical detection of self-assembled viologen modified electrode as mediator of glucose sensor

被引:3
|
作者
Dept. of Electrical Engineering and NTRC, Dong-A Univerity, Korea, Republic of [1 ]
机构
来源
J. Electr. Eng. Technol. | 2009年 / 1卷 / 106-110期
关键词
Charge transfer - Glucose sensors - Gold - Self assembled monolayers - Electrochemical electrodes - Enzyme electrodes - Chemical detection - Glucose - Electrochemical biosensors - Quartz crystal microbalances;
D O I
10.5370/JEET.2009.4.1.106
中图分类号
学科分类号
摘要
An amperometric glucose biosensor has been developed using viologen derivatives as a charge transfer mediator between a glucose oxidase (GOD) and a gold electrode. A highly stable self-assembled monolayer (SAM) of thiol-based viologen was immobilized onto the gold electrode of a quartz crystal microbalance (QCM) and GOD was immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of-300 mV. Upon immobilization of the glucose oxidase onto the viologen modified electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance, such as pH potential, were optimized and assessed. This biosensor offered excellent electrochemical responses for glucose concentration below μ mol level with high sensitivity and selectivity and short response time. The levels of the RSDs (-4 M. The detection limit was determined to be 3.0 × 10-6 M.
引用
收藏
相关论文
共 50 条
  • [1] Electrochemical Detection of Self-Assembled Viologen Modified Electrode as Mediator of Glucose Sensor
    Lee, Dong-Yun
    Choi, Won-Suk
    Park, Sang-Hyun
    Kwon, Young-Soo
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2009, 4 (01) : 106 - 110
  • [2] A glucose sensor made of an enzymatic clay-modified electrode and methyl viologen mediator
    Zen, JM
    Lo, CW
    ANALYTICAL CHEMISTRY, 1996, 68 (15) : 2635 - 2640
  • [3] Electrochemical detection of copper(II) at a gold electrode modified with a self-assembled monolayer of penicillamine
    L. M. Niu
    H. Q. Luo
    N. B. Li
    L. Song
    Journal of Analytical Chemistry, 2007, 62 : 470 - 474
  • [4] Electrochemical detection of copper(II) at a gold electrode modified with a self-assembled monolayer of penicillamine
    Niu, L. M.
    Luo, H. Q.
    Li, N. B.
    Song, L.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (05) : 470 - 474
  • [5] Electrochemical Atrazine Detection Using Au(111) Electrode Modified with Self-assembled Monolayer of Mercaptoquinone
    Umezawa, Noriko
    Tsurunari, Moe
    Kondo, Toshihiro
    CHEMISTRY LETTERS, 2009, 38 (08) : 766 - 767
  • [6] ELECTROCHEMICAL CHARACTERISTICS OF A GOLD ELECTRODE MODIFIED WITH A SELF-ASSEMBLED MONOLAYER OF FERROCENYLALKANETHIOLS
    UOSAKI, K
    SATO, Y
    KITA, H
    LANGMUIR, 1991, 7 (07) : 1510 - 1514
  • [7] A self-assembled electrochemical sensor for uranium
    Evans, CJ
    Nicholson, GP
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 105 (02): : 204 - 207
  • [8] An Electrochemical Immunosensor Based on a Self-Assembled Monolayer Modified Electrode for Label-Free Detection of α-Synuclein
    Ge, Chuang-Ye
    Rahman, Md. Mahbubur
    Zhang, Wei
    Lopa, Nasrin Siraj
    Jin, Lei
    Yoon, Sujin
    Jang, Hohyoun
    Xu, Guang-Ri
    Kim, Whangi
    SENSORS, 2020, 20 (03)
  • [9] Optical and electrochemical characterization of self-assembled octadecyltrichlorosilane monolayer on modified silicon electrode
    Abdelghani, A
    Hleli, S
    Cherif, K
    MATERIALS LETTERS, 2002, 56 (06) : 1064 - 1068
  • [10] Electrochemical behavior of gold electrode modified densely with self-assembled monolayer of ferrocenylalkanethiol
    Zhou Mi
    Zhu Jun-Jie
    Zhao Jian-Wei
    CHINESE JOURNAL OF INORGANIC CHEMISTRY, 2007, 23 (01) : 46 - 50