RESEARCH ON COOPERATIVE OPTIMAL CONTROL OF ELECTRICITY STORAGE AND HEAT STORAGE CONSIDERING ABANDONED WIND CONSUMPTION

被引:0
|
作者
Liu Y. [1 ]
Xie L. [1 ]
Peng W. [1 ]
Xu X. [1 ]
Ma L. [1 ]
Bao H. [2 ]
机构
[1] Research Center of Renewable Energy Power Generation and Grid Control Engineering, Ministry of Education, Xinjiang University, Urumqi
[2] CSIC of Haiwei (Xinjiang)New Energy Co.,Ltd., Urumqi
来源
关键词
energy storage; heat storage electric boiler; heating; optimized control; wind power accommodation;
D O I
10.19912/j.0254-0096.tynxb.2021-1407
中图分类号
学科分类号
摘要
In view of the long heating period in Xinjiang region and the serious abandoned wind during the heating period,using the heat storage electric boilers to convert wind energy is considered to promote the local consumption of abandoned wind. Firstly,considering the uncertainties such as the rapid fluctuation and randomness of wind power,the electrochemical energy storage with flexible adjustment and two-way flow function is introduced to cooperate with the heat storage electric boilers to absorb the abandoned wind. Then the heat supply model of the heat-electricity storage system is established,and the simulation scheduling is carried out according to the proposed optimal control strategy. Finally,taking the real data of a wind farm in Xinjiang as an example,the economy and effectiveness of the proposed scheme are verified by simulation analysis and the comparison of the abandoned wind absorption rate and heating benefit under different heating schemes. © 2023 Science Press. All rights reserved.
引用
收藏
页码:276 / 282
页数:6
相关论文
共 12 条
  • [1] ZHANG S X, WANG D Y,, CHENG H Z,, Et al., Key technologies and challenges of low- carbon integrated energy system planning for carbon emission peak and carbon neutrality[J], Automation of electric power systems, 46, 8, pp. 189-207, (2022)
  • [2] DING T, Analyzing current development and typical cases of clean heating supply in northwest China(I):policy status and existing problems [J], Proceedings of the CSEE, 40, 15, pp. 4881-4891, (2020)
  • [3] Notice on the issuance of the winter clean heating plan in the northern region(2017-2021)[EB/OL]
  • [4] SHANG X Q, SUN M., Optimal dispatching of power grid based on wind power and heat storage heating system[J], Acta energiae solaris sinica, 42, 7, pp. 65-70, (2021)
  • [5] LYU Q, LIU L, Et al., Research on coal-saving performance and optimal configuration of wind power heating project considering wind power curtailment characteristics[J], Proceedings of the CSEE, 37, 16, pp. 4699-4711, (2017)
  • [6] YU J, SHEN X W., Optimal operating strategy of integrated power system with wind farm,CHP unit and heat storage device[J], Electric power automation equipment, 37, 6, pp. 139-145, (2017)
  • [7] GE W C, LI J Y, LI J H, Et al., Optimized control strategy for large- capacity heat storage system to improve wind power consumption[J], Acta energiae solaris sinica, 40, 2, pp. 380-386, (2019)
  • [8] YANG X Y, ZHANG Y, XIE Z J,, Et al., Multi-objective bi-level of optimization operation of wind power accommodation for heat storage electric boiler combined with wind power [J], Acta energiae solaris sinica, 41, 1, pp. 273-281, (2020)
  • [9] LI J, Economic optimal configuration of hybrid energy storage system for improving wind power consumption[J], Power system technology, 44, 12, pp. 4547-4557, (2020)
  • [10] LYU Q,, Li L,, ZHU Q S,, Et al., Comparison of coal-saving effect and national economic indices of three feasible curtailed wind power accommodating strategies[J], Automation of electric power systems, 39, 7, pp. 75-83, (2015)