A basic study on estimation of foot dorsiflexion movement during walking from measurement in sitting position for FES-assisted foot drop correction

被引:0
|
作者
机构
[1] Shiotani, Maho
[2] Watanabe, Takashi
[3] Endo, Shun
[4] Murakami, Katsunori
[5] Kumagai, Yoshimi
[6] Kuge, Naomi
关键词
D O I
10.11239/jsmbe.52.O-25
中图分类号
学科分类号
摘要
Functional electrical stimulation (FES) is effective to correct foot drop. Although electrode position and stimulation intensity to develop appropriate dorsiflexion are determined in sitting position, FES movement during walking may differ from that in sitting position. That is, it is better to determine appropriate electrode position and stimulation parameters by estimating foot movement during walking from measurement in sitting position. In this report, ankle dorsiflexion angle during FES-assisted walking and that developed by electrical stimulation in sitting position were measured on two hemiplegic subjects with inertial sensors. In both subjects, there were some trials that dorsiflexion angle at 95% of gait cycle was different from that in sitting position. In some trials of one subject, effect of drop foot correction decreased during gait. Decrease of dorsiflexion angle may cause falling, thus it is necessary to study reason of decrease of effect of foot drop correction. © 2014, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
引用
收藏
相关论文
共 4 条
  • [1] A Personalized FES-Assisted Foot Drop Correction Device via a Real-Time Fuzzy Controller based on the Patient's Healthy Foot Condition
    Khoobani, Mohammad
    Nazari, Mostafa
    Sepehry, Naserodin
    Ameri, Mansour
    Sahebi, Nasrin
    2021 9TH RSI INTERNATIONAL CONFERENCE ON ROBOTICS AND MECHATRONICS (ICROM), 2021, : 497 - 503
  • [2] A Basic Study on Quantitative Evaluation of 3-dimensional Foot Contact with an Inertial Sensor for FES Foot Drop Correction
    Shiotani, Maho
    Watanabe, Takashi
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6684 - 6687
  • [3] A Pilot Study of Relationship Between Hip Joint Movement and FES Foot Drop Correction with a Hemiplegic Subject
    Kikuchi, Kei
    Watanabe, Takashi
    Morita, Ryusei
    Murakami, Katsunori
    Kuge, Naomi
    CONVERGING CLINICAL AND ENGINEERING RESEARCH ON NEUROREHABILITATION III, 2019, 21 : 243 - 247
  • [4] Effect of walking speed changes on tibialis anterior EMG during healthy gait for FES envelope design in drop foot correction
    Byrne, C. A.
    O'Keeffe, D. T.
    Donnelly, A. E.
    Lyons, G. M.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2007, 17 (05) : 605 - 616