Cyber attacks detection and mitigation in hybrid power system using type-2 fuzzy controller

被引:0
|
作者
Dundi, Jesraj Tataji [1 ]
Appikonda, Padmaja [2 ]
Sudha, Kasibhatla Rama [1 ]
Anguru, Jeevan Sai [1 ]
Burlagadda, Surya Venu Teja [1 ]
机构
[1] Andhra Univ, AU Coll Engn, Dept Elect Engn, Visakhapatnam, India
[2] Andhra Pradesh Univ, Dept Elect Engn, JNTU GJV, Visakhapatnam, India
来源
ENGINEERING RESEARCH EXPRESS | 2024年 / 6卷 / 04期
关键词
wind turbine generator (WTG); photovoltaic cell (PV); double layer capacitor bank (DLC); fuel cell (FC); renewable energy sources (RES); type-2; fuzzy; RENEWABLE ENERGY-SYSTEMS; GENERATION SYSTEM; SIMULATION; MANAGEMENT; LOAD;
D O I
10.1088/2631-8695/ad8dac
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents a novel control technique using Fuzzy Type-2 controller for regulating the frequency deviations in an independent Hybrid Power System ( HPS ) . The HPS comprises of a wind system and a solar photovoltaic ( PV ) system as primary energy sources, along with Fuel Cells ( FCs ) as additional generation systems and Double Layer Capacitor ( DLC ) Banks as storage devices to meet the load demand. The frequency variations occur in the HPS due to the intermittency in power outputs from the primary sources, the load changes as well as any attacks in the system. The frequency regulation is achieved by effective coordination control of FC and DLC with the aid of a Fuzzy Type-2 controller and a high pass fi lter ( HPF ) . The DLC technology adequately satisfies the residual power of hybrid systems resulting from the slow dynamics of FCs. The Fuzzy Type-2 controller is trained using an input-output data set of a PID controller whose gains are tuned to their optimal values using Monte-Carlo state estimators. The proposed system is simulated using real weather data to validate the capability of the Hybrid Power System ( HPS ) in supplying isolated loads while maintaining power frequency balance conditions. Also the HPS is subjected to attacks in daily load variation and the results are compared with the system without attacks. The simulation results show that the peak over shoots are reduced considerably but the settling time is 0.2 sin the system with no attacks where as the settling time is prolonged to 1.2 s with the attacks. This paper demonstrates the effectiveness of the Fuzzy Type-2 controller for the coordination control of DLC and FC to achieve generation-load balance condition in comparison with that of the PID controller for HPS system with and without attacks.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Operation and Control of a Hybrid Isolated Power System with Type-2 Fuzzy PID Controller
    Rawat, Swati
    Jha, Bhola
    Panda, Manoj Kumar
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2018, 42 (04) : 403 - 417
  • [2] Operation and Control of a Hybrid Isolated Power System with Type-2 Fuzzy PID Controller
    Swati Rawat
    Bhola Jha
    Manoj Kumar Panda
    Iranian Journal of Science and Technology, Transactions of Electrical Engineering, 2018, 42 : 403 - 417
  • [3] Intelligent System Stability using Type-2 Fuzzy Controller
    Nagarajan, D.
    Kavikumar, J.
    Lathamaheswari, M.
    Broumi, S.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (01): : 270 - 282
  • [4] Type-2 Fuzzy Controller for Stability of a System
    Nagarajan, D.
    Lathamaheswari, M.
    Kavikumar, J.
    CYBERNETICS AND AUTOMATION CONTROL THEORY METHODS IN INTELLIGENT ALGORITHMS, 2019, 986 : 197 - 213
  • [5] Type-2 Fuzzy Hybrid Controller Network for Robotic Systems
    Chao, Fei
    Zhou, Dajun
    Lin, Chih-Min
    Yang, Longzhi
    Zhou, Changle
    Shang, Changjing
    IEEE TRANSACTIONS ON CYBERNETICS, 2020, 50 (08) : 3778 - 3792
  • [6] Interval Type-2 Fuzzy Logic Control-Based Frequency Control of Hybrid Power System Using DMGS of PI Controller
    Rawat, Swati
    Jha, Bhola
    Panda, Manoj Kumar
    Kanti, Jyotshana
    APPLIED SCIENCES-BASEL, 2021, 11 (21):
  • [7] Frequency control in hybrid distributed power systems via type-2 fuzzy PID controller
    Kumar Khadanga, Rajendra
    Kumar, Amit
    Panda, Sidhartha
    IET RENEWABLE POWER GENERATION, 2021, 15 (08) : 1706 - 1723
  • [8] Power System Stabilizer Design: Interval Type-2 Fuzzy logic controller Approach
    Panda, Manoj Kumar
    Pillai, G. N.
    Kumar, Vijay
    2012 2ND INTERNATIONAL CONFERENCE ON POWER, CONTROL AND EMBEDDED SYSTEMS (ICPCES 2012), 2012,
  • [9] Improved performance of active power filter using type-2 fuzzy logic controller
    Suresh, Dhanavath
    Singh, S. P.
    2014 IEEE 6TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2014,
  • [10] Effect of Electric Vehicles and Renewable Sources on Frequency Regulation in Hybrid Power System Using QOAOA Optimized Type-2 Fuzzy Fractional Controller
    Mrinal Ranjan
    Ravi Shankar
    International Journal of Fuzzy Systems, 2024, 26 : 825 - 848