Measurements Of Plasma Termination In Icrf Heated Long Pulse Discharges With Fast Framing Cameras In The Large Helical Device

被引:0
|
作者
Shoji, Mamoru [2 ]
Kasahara, Hiroshi [2 ]
Tanaka, Hirohiko [2 ]
Seki, Tetsuo [2 ]
Saito, Kenji [2 ]
Kamio, Shuji [2 ]
Seki, Ryosuke [2 ]
Mutoh, Takashi [2 ]
Tokitani, Masayuki [2 ]
Morita, Shigeru [2 ]
Goto, Motoshi [2 ]
Oishi, Tetsutaro [2 ]
Cal, Eduardo De La [1 ]
Hidalgo, Carlos [1 ]
Yamada, Hiroshi [2 ]
Group, Lhd Experiment [2 ]
机构
[1] Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, 40 Avenida Complutense, Madrid, Spain
[2] National Institute for Fusion Science, 322-6 Oroshi-cho, Toki,509-5292, Japan
关键词
Antennas - Cameras - Electric discharges - Metal ions;
D O I
10.1585/pfr.10.3402040
中图分类号
学科分类号
摘要
The termination process of long pulse plasma discharges in the Large Helical Device (LHD) have been observed with fast framing cameras, which shows that the reason for the termination of the discharged has been changed with increased plasma heating power, improvements of plasma heating systems and change of the divertor configuration, etc. For long pulse discharges in FYs2010-2012, the main reason triggering the plasma termination was reduction of ICRF heating power with rise of iron ion emission due to electric breakdown in an ICRF antenna. In the experimental campaign in FY2013, the duration time of ICRF heated long pulse plasma discharges has been extended to about 48 minutes with a plasma heating power of ~1.2MW and a line-averaged electron density of ~ 1.2 × 1019 m−3. The termination of the discharges was triggered by release of large amounts of carbon dusts from closed divertor regions, indicating that the control of dust formation in the divertor regions is indispensable for extending the duration time of long pulse discharges. © 2015 The Japan Society of Plasma Science and Nuclear Fusion Research
引用
收藏
页码:1 / 5
相关论文
共 49 条
  • [31] Effects of relativistic frequency downshift on measurements of electron cyclotron emission in Large Helical Device plasma
    Sato, M
    Isayama, A
    Inagaki, S
    Nagayama, Y
    Kawahata, K
    Iwama, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3819 - 3821
  • [32] Initial long-pulse plasma heating at reduced power with negative-ion-based neutral beam injector in large helical device
    Takeiri, Y
    Noda, N
    Nakamura, Y
    Oka, Y
    Osakabe, M
    Kawahata, K
    Kaneko, O
    Tsumori, K
    Sato, M
    Mutoh, T
    Goto, M
    Ida, K
    Inagaki, S
    Kado, S
    Masuzaki, S
    Morita, S
    Nagayama, Y
    Peterson, BJ
    Sagara, A
    Sakakibara, S
    Sato, K
    Tanaka, K
    Sudo, S
    Ohyabu, N
    Motojima, O
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (11): : 4260 - 4265
  • [33] Shafranov shift measurements by a soft x-ray CCD camera for internal diffusion barrier discharges in the Large Helical Device
    Suzuki, C.
    Ida, K.
    Sakamoto, R.
    Yoshinuma, M.
    NUCLEAR FUSION, 2010, 50 (06)
  • [34] Study on Knock-on Tail Formation in Deuteron Velocity Distribution Function Due to ICRF-Heated Energetic Proton by Using Neutron Diagnostics in the Large Helical Device
    Umezaki D.
    Matsuura H.
    Kimura K.
    Fukuda T.
    Ogawa K.
    Isobe M.
    Kamio S.
    Kawamoto Y.
    Oishi T.
    Plasma and Fusion Research, 2023, 18
  • [35] Characteristics of long-pulse negative-ion source in the neutral beam injector of Large Helical Device
    Takeiri, Y
    Ikeda, K
    Oka, Y
    Tsumori, K
    Osakabe, M
    Nagaoka, K
    Kaneko, O
    Asano, E
    Kondo, T
    Sato, M
    Shibuya, M
    Komada, S
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [36] Study on Knock-on Tail Formation in Deuteron Velocity Distribution Function Due to ICRF-Heated Energetic Proton by Using Neutron Diagnostics in the Large Helical Device
    Umezaki, Daisuke
    Matsuura, Hideaki
    Kimura, Kento
    Fukuda, Takahito
    Ogawa, Kunihiro
    Isobe, Mitsutaka
    Kamio, Shuji
    Kawamoto, Yasuko
    Oishi, Tetsutaro
    PLASMA AND FUSION RESEARCH, 2023, 18
  • [37] Study on Fast Deuteron Diagnostics Method Using Fast 3He Visible Spectra in the Large Helical Device Deuterium Plasma
    Kimura, Kento
    Matsuura, Hideaki
    Itoh, Chujo
    Kawamoto, Yasuko
    Oishi, Tetsutaro
    Goto, Motoshi
    Ogawa, Kunihiro
    Nishitani, Takeo
    Isobe, Mitsutaka
    Osakabe, Masaki
    PLASMA AND FUSION RESEARCH, 2023, 18
  • [38] Heat pulse propagation across the rational surface in a large helical device plasma with counter-neutral beam injection
    Yakovlev, M
    Inagaki, S
    Shimozuma, T
    Kubo, S
    Morisaki, T
    Nagayama, Y
    Kawahata, K
    Komori, A
    PHYSICS OF PLASMAS, 2005, 12 (09) : 1 - 6
  • [39] Fast Ion Confinement Study by Neutron Emission Rate Measurement after Short Pulse NB Injection in the Large Helical Device
    Nishitani, Takeo
    Ogawa, Kunihiro
    Pu, Neng
    Kawase, Hiroki
    Murakami, Sadayoshi
    Isobe, Mitsutaka
    Osakabe, Masaki
    PLASMA AND FUSION RESEARCH, 2018, 13
  • [40] Plasma termination by excess pellet fueling and impurity injection in TJ-II, the Large Helical Device and Wendelstein 7-X
    Dinklage, A.
    McCarthy, K. J.
    Suzuki, C.
    Tamura, N.
    Wegner, Th
    Yamada, H.
    Baldzuhn, J.
    Brunner, K. J.
    Buttenschoen, B.
    Damm, H.
    Drewelow, P.
    Fuchert, G.
    Hirsch, M.
    Hoefel, U.
    Kasahara, H.
    Knauer, J.
    Maier, D.
    Miyazawa, J.
    Motojima, G.
    Oishi, T.
    Rahbarnia, K.
    Pedersen, T. Sunn
    Sakamoto, R.
    Wolf, R. C.
    Zhang, D.
    NUCLEAR FUSION, 2019, 59 (07)