A New Resonant Control Strategy for Three-phase Grid Connected Inverter

被引:0
|
作者
Ma W. [1 ]
Ouyang S. [1 ]
Yang L. [1 ]
机构
[1] School of Electric Power, South China University of Technology, Guangzhou, 510640, Guangdong Province
来源
关键词
Frequency adaptability; Resonant control; Three-phase grid-connected inverter;
D O I
10.13335/j.1000-3673.pst.2018.2296
中图分类号
学科分类号
摘要
To solve the problem that conventional proportional resonant (PR) controller used for grid-connected inverter cannot achieve zero steady-state error tracking control when grid frequency is shifted, a new resonant control method with frequency adaptive capacity is proposed in this paper. In a two-phase static coordinate system, the three-phase grid-connected inverter control system based on traditional quasi-PR controller is improved. With introduction of frequency tracking link and pre-current feedback link, the whole control system is equivalent to a first-order frequency servo system. The frequency adaptive dynamic response and steady-state control performance of the new resonant control strategy are analyzed, and the design method of key control parameters is given. Finally, effectiveness of the proposed scheme is proved with simulation and experiment. © 2019, Power System Technology Press. All right reserved.
引用
收藏
页码:2884 / 2891
页数:7
相关论文
共 18 条
  • [1] Liu Z., Zhu C., Wang Y., Et al., Two improved repetitive control methods against frequency fluctuation in IPS, Power System Technology, 42, 9, pp. 3014-3023, (2018)
  • [2] Hou X., Qin L., Mao J., Et al., Design of input voltage robust PI+QPR controller for two-stage single-phase PV grid- connected inverter, Power System Technology, 41, 9, pp. 2910-2918, (2017)
  • [3] Teodorescu R., Blaabjerg F., Liserre M., Et al., Proportional-resonant controllers and filters for grid-connected voltage-source converters, IEE Proceedings-Electric Power Applications, 153, 5, pp. 750-762, (2006)
  • [4] Khajehoddin S.A., Karimi-Ghartemani M., Jain P.K., Et al., A resonant controller with high structural robustness for fixed-point digital implementations, IEEE Transactions on Power Electronics, 27, 7, pp. 3352-3362, (2012)
  • [5] Castilla M., Miret J., Camacho A., Et al., Reduction of current harmonic distortion in three-phase grid-connected photovoltaic inverters via resonant current control, IEEE Transactions on Industrial Electronics, 60, 4, pp. 1464-1472, (2013)
  • [6] Wang X., Blaabjerg F., Liserre M., Et al., An active damper for stabilizing power-electronics-based AC systems, IEEE Transactions on Power Electronics, 29, 7, pp. 3318-3329, (2014)
  • [7] Wei Z., Ru X., Shi W., Et al., Control strategy for micro grid inverter under unbalanced load conditions, Automation of Electric Power Systems, 40, 20, pp. 76-82, (2016)
  • [8] Zhang X., Pei W., Deng W., Et al., Control strategy of three- phase parallel PWM rectifier under unbalanced gird voltage, Power System Technology, 42, 1, pp. 330-337, (2018)
  • [9] Liu B., Xie J., Li J., Novel grid-connected current control strategies based on self-adaptive proportional-resonant, Transactions of China Electrotechnical Society, 28, 9, pp. 186-195, (2013)
  • [10] Yang Q., Liang X., Guo X., Et al., Application of quasi resonant controller for active power filter, Transactions of China Electrotechnical Society, 24, 7, pp. 171-176, (2009)