Development of titanium needle probes for neural recording and evaluation of magnetic resonance imaging artifacts

被引:1
|
作者
Yoon H. [1 ,4 ]
Deshpande D.C. [1 ,4 ]
Kim T.H. [2 ]
Jeong E.-K. [3 ,6 ]
Harbaugh R.E. [4 ]
Varadan V.K. [3 ,5 ,6 ]
机构
[1] Department of Electrical Engineering, Innovative Nano/Bio Devices and Systems Laboratory, University of Arkansas, Research Center Boulevard 700, Fayetteville
[2] Department of Radiology, Utah Center for Advanced Imaging, Research, University of Utah, Salt Lake City, UT 84108-1218
[3] Department of Neurosurgery, College of Medicine, Pennsylvania State Hershey Medical Center, 500 University Drive, Hershey
[4] Laboratory, University of Arkansas, Research Center Boulevard 700, Fayetteville
[5] Department of Electrical Engineering, Innovative Nano/Bio Devices and Systems Laboratory, University of Arkansas 700 Research Center Boulevard, Fayetteville
[6] Department of Neurosurgery, College of Medicine, Pennsylvania State Hershey Medical Center, 500 University Drive, Hershey
关键词
D O I
10.1115/1.4000039
中图分类号
学科分类号
摘要
The aim of this research is to develop a mechanically flexible and strong neural probe with microelectrode array for future clinical applications in neural prosthetics and neurological disorder fields. This research specifically focuses on the development of neural recording electrodes with iridium oxide IrOx electrodes on a titanium needle probe and discusses the fabrication techniques and their evaluation for physical properties and electrochemical performance. Microfabrication processes, such as inductive coupled plasma etching, were used to deeply etch the Ti needle structures on titanium foils, and microelectrode arrays with iridium oxide films were formed by electrochemical deposition for low impedance neural recording. Mechanical and electrochemical analyses were performed to verify the viability of Ti needle probes in vitro. The final section of this paper addresses the issue of magnetic resonance imaging artifacts of titanium needle probes, and test results are compared with similarly fabricated Si needle probes. The advantages of using a titanium needle probe are discussed in the application of neural probe electrodes, as well. © 2010 by ASME.
引用
收藏
相关论文
共 50 条
  • [1] Metallic needle artifacts in magnetic resonance imaging
    Liu, HY
    JOURNAL OF APPLIED PHYSICS, 1998, 83 (11) : 6849 - 6851
  • [2] Artifacts in Magnetic Resonance Imaging
    Krupa, Katarzyna
    Bekiesinska-Figatowska, Monika
    POLISH JOURNAL OF RADIOLOGY, 2015, 80 : 93 - 106
  • [3] Artifacts in Breast Magnetic Resonance Imaging
    Anthony, Marina-Portia
    Dustin Nguyen
    Friedlander, Lauren
    Mango, Victoria
    Wynn, Ralph
    Ha, Richard
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2016, 45 (04) : 271 - 277
  • [4] ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING
    HENKELMAN, RM
    BRONSKILL, MJ
    MEDICAL PHYSICS, 1987, 14 (03) : 506 - 507
  • [5] Orbital artifacts on magnetic resonance imaging
    Rana, Khizar
    Juniat, Valerie
    Patel, Sandy
    Avey, Greg
    Lucarelli, Mark
    Selva, Dinesh
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 935 - 935
  • [6] Solid phase synthesis in the development of magnetic resonance imaging probes
    Connah, Liam
    Angelovski, Goran
    ORGANIC CHEMISTRY FRONTIERS, 2020, 7 (24) : 4121 - 4141
  • [7] Reduction of Gibbs Artifacts in Magnetic Resonance Imaging Based on Convolutional Neural Network
    Wang, Yida
    Song, Yang
    Xie, Haibin
    Li, Wenjing
    Hu, Bingwen
    Yang, Guang
    2017 10TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI), 2017,
  • [8] Multiple-mouse magnetic resonance imaging with cryogenic radiofrequency probes for evaluation of brain development
    Arbabi, A.
    Noakes, L. Spencer
    Vousden, D.
    Dazai, J.
    Spring, S.
    Botelho, O.
    Keshavarzian, T.
    Mattingly, M.
    Ellegood, J. E.
    Nutter, L. M. J.
    Wissmann, R.
    Sled, J. G.
    Lerch, J. P.
    Henkelman, R. M.
    Nieman, B. J.
    NEUROIMAGE, 2022, 252
  • [9] Perceptual evaluation of artifacts in cardiac magnetic resonance imaging due to partial parallel imaging
    Johnson, JP
    Kirchberg, KJ
    Lorenz, CH
    Medical Imaging 2005: Image Perception, Observer Performance, and Technology Assessment, 2005, 5749 : 549 - 556
  • [10] Parallel Imaging Artifacts in Body Magnetic Resonance Imaging
    Noel, Patricia
    Bammer, Roland
    Reinhold, Caroline
    Haider, Masoom A.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2009, 60 (02): : 91 - 98