New transient method for earth fault line selection in resonant grounded power system based on morphological filtering

被引:0
|
作者
North China Electric Power University, Beijing 102206, China [1 ]
机构
来源
Dianli Xitong Zidonghue | 2008年 / 12卷 / 73-77期
关键词
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Study on fault line selection based on transient and mathematical morphology in resonant grounded system
    Qu Yilong
    Tan Weipu
    Cong Shuan
    Yang Yihan
    2006 INTERNATIONAL CONFERENCE ON POWER SYSTEMS TECHNOLOGY: POWERCON, VOLS 1- 6, 2006, : 1287 - +
  • [3] Transient Fault Line Selection Method for Flexible Grounded System Based on Transition Resistance Evaluation
    Tang T.
    Zhou Y.
    Zeng X.
    Luo C.
    Li X.
    Yuan K.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (05): : 171 - 179
  • [4] A New fault Line Selection Method For Resonant Grounded Distribution Network Based on Chi-square Distance
    Cheng, Chang
    Shao, Wenquan
    Zhang, Ying
    Goan, Xin
    2021 8TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2021, : 345 - 348
  • [5] Research on a method of fault line selection for single-phase earth fault in ineffectively grounded power systems
    Lu, Gai-Feng
    Hua, Yu
    Jin, Xiao-Bing
    Ren, Zhi-Qiang
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (12): : 44 - 49
  • [6] New method for transient line selection in distribution system based on grounding fault transferred
    Li, Yilin
    Yin, Xianggen
    Chen, Rui
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 2822 - 2826
  • [7] Fault Line Selection Method for High-Impedance Grounding Fault of Resonant Grounded System Based on Change Rate of Virtual Energy
    Wang Z.
    Wu S.
    Luan X.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (03): : 137 - 146
  • [8] A Method for Fault Line Detecting Based on Cluster in Resonant Grounded Systems
    Li Bin
    Shu Hongchun
    2009 INTERNATIONAL CONFERENCE ON SUSTAINABLE POWER GENERATION AND SUPPLY, VOLS 1-4, 2009, : 2439 - 2442
  • [9] Research on Extension Method and Detection of Fault-Line Selection in Resonant Grounded Systems
    Li Bin
    Shu Hongchun
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 723 - 726
  • [10] Fault Line Selection in Resonant Earthed System Based on Morphological Peak-Valley Detection
    Shu H.
    Huang H.
    Tian X.
    Dong J.
    Huang R.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (01): : 228 - 233