Determination of Dioxins and Dioxin-like Polychlorinated Biphenyls in Pork by Gas Chromatography-Tandem Mass Spectrometry

被引:0
|
作者
Lu J. [1 ]
Jiao Y. [1 ]
Cheng J. [1 ]
Shen T. [1 ]
Zhu S. [1 ]
Fu S. [1 ]
机构
[1] Hunan Key Laboratory of Food Safety Science & Technology, Technology Center of Changsha Customs, Changsha
来源
Shipin Kexue/Food Science | 2023年 / 44卷 / 18期
关键词
dioxin-like polychlorinated biphenyls; dioxins; gas chromatography-tandem mass spectrometry; pork;
D O I
10.7506/spkx1002-6630-20221108-080
中图分类号
学科分类号
摘要
A gas chromatography-tandem mass spectrometry (GC-MS/MS) with stable isotope dilution (SID) method was established for the determination of dioxins (PCDD/Fs) and dioxin like polychlorinated biphenyls (DL-PCBs) in pork. The sample was extracted by Soxhlet extraction, defatted using acidified silica gel, and purified by sequential chromatography on a multi-layer silica gel column, an alkaline alumina column and an activated carbon column. PCDD/Fs- and DL-PCBs-rich fractions were collected separately, concentrated and redissolved for GC-MS/MS analysis. The influence of defatting method and fat content on the purification efficiency was investigated, and the blank contamination source of the system was discussed. The results showed that gel permeation chromatography (GPC) degreasing had a great influence on the recovery of PCDD/Fs and DL-PCBs, and acidified silica gel degreasing was more suitable for the analysis and detection of ultra-trace dioxins. The major blank pollution source of the dioxin detection system was the Soxhlet extractor. The recoveries for internal standard were 45.3%–122.4% with relative standard deviation (RSD) of 1.0%–14.7%. The recoveries for the analytes were 64.9%–118.8% with RSD of 1.1%–14.7%. Both the linearity and limit of detection (LOD) met the requirements of the national standard of China GB 5009.205-2013. The proposed method is suitable for the determination of PCDD/Fs and DL-PCBs in actual pork samples. © 2023 Chinese Chamber of Commerce. All rights reserved.
引用
收藏
页码:364 / 371
页数:7
相关论文
共 22 条
  • [1] 3, pp. 93-94, (2020)
  • [2] PETRLIK J, BELL L, DIGANGI J, Et al., Monitoring dioxins and PCBs in eggs as sensitive indicators for environmental pollution and global contaminated sites and recommendations for reducing and controlling releases and exposure, Emerging Contaminants, 8, pp. 254-279, (2022)
  • [3] CAO Y, JIANG D, LI F, Et al., Dioxin-like polychlorinated biphenyls in marine fish from Shandong, China, and human dietary exposure, Food Additives & Contaminants Part B, 11, 3, pp. 229-236, (2018)
  • [4] CORTES S., Levels of polychlorinated dibenzo-p-dioxins/furans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs) in human breast milk in chile: a pilot study, International Journal of Environmental Research and Public Health, 18, 9, pp. 4825-4829, (2021)
  • [5] HOULIHAN M, WEMKEN N, KEOGH M, Et al., Concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) in human milk from Ireland: temporal trends and implications for nursing infant exposure, Journal of Environmental Exposure Assessment, 1, 1, (2021)
  • [6] Setting maximum levels for certain contaminants in food stuffs[S], (2006)
  • [7] TAO T., 畜产品中二恶英的危害及检测技术, 中国牧业通讯, 7, pp. 54-56, (2011)
  • [8] HAEDRICH J, STUMPF C, DENISON M., Commission Regulation (EU) 2017/644 of 5 April 2017
  • [9] GUIDOTTI M, PROTANO C, DOMINICI C, Et al., Determination of selected polychlorinated dibenzo-p-dioxins/furans in marine sediments by the application of gas-chromatography-triple quadrupole mass spectrometry, Bulletin of Environmental Contamination & Toxicology, 90, 5, pp. 525-530, (2013)
  • [10] KWON Y S, CHOI S G, LEE S M, Et al., Gas chromatography-triple quadrupole mass spectrometry analysis of dioxins in soil, Acta Chromatographica, 31, 3, pp. 1-6, (2019)