Dual barrier protected membrane roof assemblies

被引:0
|
作者
Lyte W.A. [1 ]
机构
[1] Halsall Associates Limited, United States
来源
Journal of ASTM International | 2011年 / 8卷 / 10期
关键词
Dual barrier; Protected membrane roof; storm water management; Vapor permeable;
D O I
10.1520/JAI103744
中图分类号
学科分类号
摘要
Durable roof design is accomplished through the selection of proven high performance materials that are detailed to accepted standards and assembled by skilled tradespeople. Leak prevention is a high concern of building owners that can be addressed by protected membrane dual barrier roofs. The case studies herein illustrate the improvement of the membrane and insulation. Typically, roofing membranes are generally the only barrier for managing moisture (rain, vapor pressure, air movement) through a building's roof. The position of the insulation is also an important consideration because insulation on the membrane's exterior protects it from thermal shock and generally extends the roof membrane's service life. Largely for this reason, protected roof membranes have been recognized for their superior performance over that of conventional roofs because the insulation protects the primary roofing membrane from wide temperature fluctuations, solar radiation, and foot traffic over the roof membrane. The concept of dual barrier roofing simply includes (a) designing a new roof assembly to include at least one "extra" layer of moisture protection or (b) simply designing the standard existing roof components to resist the elements in order to further improve the performance of a protected roof assembly. Case studies are presented that summarize the physical attributes for dual barrier roofing, both in new construction and for roof replacement/renewal projects. Measured performance comparisons indicate that a dual barrier protected membrane roof can be on the order of 10 % to 20 % more thermally efficient that a typical protected membrane [Tobiasson, W., and Richard, J., "Moisture Gain and Its Thermal Consequence for Common Roof Insulations," NRCA Fifth Conference on Roofing Technology, US Army Cold Regions Research & Engineering Laboratory, Gaithersburg, Maryland, April 1979; Beech, J. C., and Saunders, G. K., "The Performance of Lightweight Inverted Flat Roofs, Building Research Establishment," NRCA Second International Symposium on Roofing Technology, Princes Risborough Laboratory, Buckingshamshire, United Kingdom, September 1985]. Additional performance and service life benefits are also summarized. Copyright © 2011 by ASTM International.
引用
收藏
相关论文
共 50 条
  • [1] WETTING OF POLYSTYRENE AND URETHANE ROOF INSULATIONS IN THE LABORATORY AND ON A PROTECTED MEMBRANE ROOF.
    Tobiasson, Wayne
    Greatorex, Alan
    Van Pelt, Doris
    1600, (11):
  • [2] A constrained dual membrane wave barrier
    Lo, EYM
    ENVIRONMENTAL HYDRAULICS, 1999, : 923 - 928
  • [3] Flexible dual membrane wave barrier
    Lo, EYM
    JOURNAL OF WATERWAY PORT COASTAL AND OCEAN ENGINEERING-ASCE, 1998, 124 (05): : 264 - 271
  • [4] Hygrothermal performance of protected membrane roof systems: Part 2: experimental verification
    Hens, H.
    Journal of thermal insulation and building envelopes, 1996, 19 : 314 - 335
  • [5] Silicon Nanoribbon pH Sensors Protected by a Barrier Membrane with Carbon Nanotube Porins
    Chen, Xi
    Zhang, Huanan
    Tunuguntla, Ramya H.
    Noy, Aleksandr
    NANO LETTERS, 2019, 19 (02) : 629 - 634
  • [6] Roof: The original air barrier
    Interface (Raleigh, North Carolina), 1996, 14 (10):
  • [7] WIND RESISTANCE TESTING FOR ROOF ASSEMBLIES.
    Coursey, Richard
    Plant Engineering (Barrington, Illinois), 1988, 42 (03): : 174 - 176
  • [8] Membrane Distillation Provides a Dual Barrier for Coronavirus and Bacteriophage Removal
    Hardikar, Mukta
    Ikner, Luisa A.
    Felix, Varinia
    Presson, Luke K.
    Rabe, Andrew B.
    Hickenbottom, Kerri L.
    Achilli, Andrea
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2021, 8 (08) : 713 - 718
  • [9] MEMBRANE ROOF STRUCTURES
    Corte, Carsten
    VII INTERNATIONAL CONFERENCE ON TEXTILE COMPOSITES AND INFLATABLE STRUCTURES (STRUCTURAL MEMBRANES 2017), 2017, : 478 - 502
  • [10] Wind Uplift Performance of Composite Metal Roof Assemblies
    Baskaran, A.
    Molleti, S.
    Ko, S.
    Shoemaker, L.
    JOURNAL OF ARCHITECTURAL ENGINEERING, 2012, 18 (01) : 2 - 15