Refined one-dimensional modeling and experimental validation of scroll compressor with vapor injection for electric vehicles

被引:2
|
作者
Li, Kang [1 ]
Hu, Jiayun [1 ]
Li, Chao [2 ]
Zhou, Xuejin [3 ]
Liu, Ni [1 ]
Zhang, Hua [1 ]
Dou, Binlin [1 ]
He, Qize [4 ]
Tu, Ran [3 ]
Su, Lin [1 ]
Mohtaram, Soheil [1 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, Shanghai 200093, Peoples R China
[2] Invest Design & Res Inst Co Ltd, Shanghai 200080, Peoples R China
[3] Huaqiao Univ, Coll Mech Engn & Automat, Xiamen 361021, Peoples R China
[4] Shanghai Fire Res Inst MEM, Shanghai 200032, Peoples R China
关键词
Performance measurement; Electric vehicles; Vapor-injection scroll compressor; Numerical calculation; Heat loss; LIQUID INJECTION; PERFORMANCE; 2-PHASE; SUCTION; SYSTEM; GAS;
D O I
10.1016/j.ijrefrig.2024.09.007
中图分类号
O414.1 [热力学];
学科分类号
摘要
Vapor injection technology represents a highly promising avenue for enhancing the efficiency of heat pump systems within electric vehicles, especially in challenging cold ambient conditions. Although a simplified isentropic process is commonly employed to assess the thermodynamic functioning of scroll compressors with vapor injection (SCVI), it diverges significantly from actual operational dynamics. This study introduces a sophisticated 1D mathematical model that incorporates key factors such as internal leakage and thermal losses, thereby providing a more accurate representation of SCVI's operational realities. The research includes comprehensive performance evaluations of a short wrap profile SCVI, with a specific focus on low-temperature ambient conditions, supported by rigorous experimental validation. Comparative analyses against non-injection scenarios reveal notable enhancements, including a maximum 17.2 % increase in mass flow, a 10.5 % rise in heating capacity, and a 2.15 % improvement in heating COP. Both the simplified isentropic process calculation model and the enhanced 1D mathematical model are utilized to analyze compressor operations. The integration of internal leakage and heat loss considerations significantly narrows the gap between calculated and experimental results for heating capacity and discharge temperature, reducing discrepancies from nearly 20 % to a mere 4 %. This refined mathematical model demonstrates a high level of alignment with experimental data, achieving an accuracy within 5 % when assessing the compressor's real-world operational dynamics.
引用
收藏
页码:469 / 483
页数:15
相关论文
共 50 条
  • [1] A study of a low pressure ratio vapor injection scroll compressor for electric vehicles under low ambient conditions
    Zhang, Xinxin
    Su, Lin
    Li, Kang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 : 186 - 196
  • [2] Investigation on the performance and vapor injection characteristics of a scroll compressor for electric vehicles based on computational fluid dynamics approach
    Liu, Xinxin
    Wang, Dingbiao
    Guo, Shimai
    Wang, Guanghui
    Li, Hang
    Chen, Jiaheng
    ENERGY CONVERSION AND MANAGEMENT, 2025, 326
  • [3] Theoretical analysis and experimental validation of optimal vapor injection conditions for a low-pressure ratio scroll compressor
    Li, Kang
    Li, Chunyu
    Cao, Jian
    Liu, Ni
    Zhang, Hua
    Dou, Binlin
    Tu, Ran
    He, Qize
    Su, Lin
    Zhou, Xuejin
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 64
  • [4] One-dimensional pulse-flow modeling of a twin-scroll turbine
    Chiong, M. S.
    Rajoo, S.
    Romagnoli, A.
    Costall, A. W.
    Martinez-Botas, R. F.
    ENERGY, 2016, 115 : 1291 - 1304
  • [5] Experimental investigation on vapor injection ASHP for electric rail vehicles in cold region
    Han, Xinxin
    Zou, Huiming
    Kang, Wei
    Xu, Hongbo
    Chen, Yiyu
    Tian, Changqing
    APPLIED THERMAL ENGINEERING, 2019, 153 : 473 - 482
  • [6] Development and experimental validation of a one-dimensional dynamic hygrothermal modeling based on air humidity ratio
    Xing-guo Guo
    You-ming Chen
    Yong-qiang Deng
    Journal of Central South University, 2012, 19 : 703 - 708
  • [7] Development and experimental validation of a one-dimensional dynamic hygrothermal modeling based on air humidity ratio
    郭兴国
    陈友明
    邓永强
    Journal of Central South University, 2012, 19 (03) : 703 - 708
  • [8] Development and experimental validation of a one-dimensional dynamic hygrothermal modeling based on air humidity ratio
    Guo Xing-guo
    Chen You-ming
    Deng Yong-qiang
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2012, 19 (03): : 703 - 708
  • [9] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector:Design and experimental research
    XU ShuXue&MA GuoYuan Beijing University of Technology
    Science China(Technological Sciences), 2010, (03) : 782 - 788
  • [10] Air-source heat pump coupled with economized vapor injection scroll compressor and ejector: Design and experimental research
    Xu ShuXue
    Ma GuoYuan
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2010, 53 (03) : 782 - 788