A study on effectiveness of tuned viscous mass damper incorporated into reinforced concrete building

被引:0
|
作者
Sugimura Y. [1 ]
Ikago K. [2 ]
Goto W. [1 ]
Saito K. [3 ]
Inoue N. [2 ]
机构
[1] Research and Development Headquarters, NTT Facilities, INC.
[2] Graduate School of Engineering, Tohoku Univ.
[3] Building Engineering Headquarters, NTT Facilities, INC.
关键词
Fixed point theory; Passive control; Reinforced concrete building; Tuned viscous mass damper;
D O I
10.3130/aijt.17.841
中图分类号
学科分类号
摘要
Although it is recognized that a tuned mass damper (TMD) is very effective in reducing wind-induced response of a structure, it is not in reducing earthquake-induced response. This is because a very large supplemental mass is required for seismic control of the structure. The authors have proposed a new seismic response control system, the tuned viscous mass damper (TVMD) that has an apparent mass amplifying mechanism to obtain a large supplemental mass effect enough to suppress earthquake-induced excitations. In this paper, the applicability and effectiveness of the TVMD to an inelastic MDOF system are illustrated by a design example.
引用
收藏
页码:841 / 846
页数:5
相关论文
共 50 条
  • [1] Study on seismic upgrade of 5 storey reinforced concrete building by Tuned Mass Damper
    Tulei, E.
    Cretu, D.
    Lungu, D.
    [J]. PROTECTION OF HISTORICAL BUILDINGS - PROHITECH 09, VOL 1 AND 2, 2009, : 563 - 568
  • [2] Study, design and construction of a tuned mass damper (TMD) For concrete building floors
    Campuzano Carmona, Jorge Eliecer
    Doz, Graciela N.
    Avila, Suzana Moreira
    [J]. EURODYN 2014: IX INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, 2014, : 1761 - 1768
  • [3] Inelastic behavior of reinforced concrete structure with tuned mass damper
    Mohammed B.M.
    Güneyisi E.M.
    [J]. Asian Journal of Civil Engineering, 2024, 25 (2) : 1841 - 1856
  • [4] A stay cable with viscous damper and tuned mass damper
    Viet Hung Cu
    Han, Bing
    [J]. AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2015, 16 (04) : 316 - 323
  • [5] Improvement of tuned mass damper by using rotational inertia through tuned viscous mass damper
    Garrido, Hernan
    Curadelli, Oscar
    Ambrosini, Daniel
    [J]. ENGINEERING STRUCTURES, 2013, 56 : 2149 - 2153
  • [6] Tuned mass damper with nonlinear viscous damping
    Rudinger, F.
    [J]. JOURNAL OF SOUND AND VIBRATION, 2007, 300 (3-5) : 932 - 948
  • [7] DAMPING INCREASE IN BUILDING WITH TUNED MASS DAMPER
    KWOK, KCS
    [J]. JOURNAL OF ENGINEERING MECHANICS-ASCE, 1984, 110 (11): : 1645 - 1649
  • [8] Analitycal study of viscous damper parameters at a simple reinforced concrete frame
    Ramdani, Yusep
    Satyarno, Iman
    [J]. INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS (SCESCM 2018), 2019, 258
  • [9] Robustness of a tuned viscous mass damper (TVMD) controlled system
    Cheng, Yuhao
    Ji, Xiaodong
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2022, 25 (16) : 3349 - 3367
  • [10] Tuned Mass Damper On Reinforced Concrete Slab With Additional "X-Shaped Metal" Absorber
    Picauly, Fredy
    Priyosulistyo, Hrc
    Suhendro, Bambang
    Triwiyono, Andreas
    [J]. 2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE CIVIL ENGINEERING STRUCTURES AND CONSTRUCTION MATERIALS, 2014, 95 : 204 - 212