Effect of nozzle spray distance on the secondary cooling uniformity of continuous casting billet

被引:0
|
作者
Han Y.-S. [1 ]
Zhang J.-S. [1 ]
Zou L.-L. [1 ]
Zeng F.-Z. [2 ]
Guan M. [3 ]
Liu Q. [1 ]
机构
[1] State Key Laboratory of Advanced Metallurgy, University of Science and Technology Beijing, Beijing
[2] Xiangtan Iron & Steel Co., Ltd. of Hunan Valin., Xiangtan
[3] Jiangsu Boji Spraying Systems Co., Ltd., Yangzhou
来源
Liu, Qing (qliu@ustb.edu.cn) | 1600年 / Science Press卷 / 42期
关键词
Continuous casting billet; Heat transfer and solidification; Nozzle spray distance; Secondary cooling uniformity; Water flux distribution;
D O I
10.13374/j.issn2095-9389.2019.12.26.001
中图分类号
学科分类号
摘要
In the secondary cooling zone of continuous casting, the cooling uniformity of the billet largely depends on water flux distribution and is closely related to crack formation. Nozzle spray distance is the main influencing factor of water flux distribution in continuous casting billet. Therefore, the investigation of the effect of nozzle spray distance on secondary cooling uniformity is of considerable importance in the design and optimization of the secondary cooling system of the billet. In the present study, the water flux distributions of the nozzles used in the secondary cooling zone of continuous casting of the billet were measured under different spray distances. A heat transfer and solidification model was established to analyze the thermal behavior of 82B steel billet. The model specifically considered the distribution of secondary cooling water along the transverse direction and was calibrated via comparing the measured and simulated surface temperatures. The effect of nozzle spray distance on the secondary cooling uniformity of the billet was investigated using the model. Results show that the increase in nozzle spray distance helps to improve the uniformity of secondary cooling water along the transverse direction, resulting in the decreased transverse uniformity and increased longitudinal uniformity of surface temperature. These effects are beneficial for the internal cracks but harmful for the corner cracks of the billet. Increasing the nozzle spray distance in the first segment of the secondary cooling zone and decreasing the nozzle spray distance in the second segment of the secondary cooling zone can decrease the maximum reheating rate and increase the corner temperature, thereby achieving the purpose of simultaneously improving the internal and corner cracks of the billet. On this basis, a nozzle arrangement method, i.e., gradually increasing the nozzle spray distance along the casting direction of each segment in the secondary cooling zone was proposed. This method contributes to the improvement of "longitudinal-transverse" cooling uniformity of the continuous casting billet. © All right reserved.
引用
收藏
页码:739 / 746
页数:7
相关论文
共 25 条
  • [1] Zhang F Q, Wang X H., Simulation of uneven cooling along the width of continuously cast slab in secondary cooling zone, Iron Steel, 41, 9, (2006)
  • [2] Assuncao C, Tavares R, Oliveira G., Improvement in secondary cooling of continuous casting of round billets through analysis of heat flux distribution, Ironmaking Steelmaking, 42, 1, (2015)
  • [3] Brimacombe J K, Sorimachi K., Crack formation in the continuous casting of steel, Metall Trans B, 8, 2, (1977)
  • [4] Han C J, Cai K K, Zhao J G, Et al., Solidification heat transfer process and control for secondary cooling zone of slab casting, J Univ Sci Technol Beijing, 21, 6, (1999)
  • [5] Min Y, Liu C J, Wang D Y, Et al., Prediction of equiaxed crystal ratio of continuous casting round billet of 37Mn5 steel, J Iron Steel Res, 23, 10, (2011)
  • [6] Zeng J, Chen W Q., Effect of secondary cooling conditions on solidification structure and central macrosegregation in continuously cast high-carbon rectangular billet, High Temp Mater Processes, 34, 6, (2015)
  • [7] Dou K, Yang Z G, Liu Q, Et al., Influence of secondary cooling mode on solidification structure and macro-segregation behavior for high-carbon continuous casting bloom, High Temp Mater Process, 36, 7, (2017)
  • [8] Fan H L, Long M J, Yu S, Et al., Uniform secondary cooling pattern for minimizing surface reheating of the strand during round bloom continuous casting, JOM, 70, 2, (2018)
  • [9] Ma J C, Wang B, Zhang D, Et al., Optimization of secondary cooling water distribution for improving the billet quality for a small caster, ISIJ Int, 58, 5, (2018)
  • [10] Wang X Y, Liu Q, Wang B, Et al., Optimal control of secondary cooling for medium thickness slab continuous casting, Ironmaking Steelmaking, 38, 7, (2011)