Utilizing tuned mass damper for reduction of seismic pounding between two adjacent buildings with different dynamic characteristics

被引:0
|
作者
Kamgar, Reza [1 ]
Dadkhah, Masoud [2 ]
Heidarzadeh, Heisam [1 ]
Javanmardi, Mahmoud Seidali [1 ]
机构
[1] Shahrekord Univ, Fac Engn, Civil Engn Dept, Shahrekord, Iran
[2] Shahid Bahonar Univ Kerman, Civil Engn Dept, Kerman, Iran
关键词
Tuned mass damper; Pounding force; Concentrated plasticity method; Optimization algorithm; Nonlinear time history analysis; Damage index; INELASTIC STRUCTURES; ENERGY-DISSIPATION; PERFORMANCE; EARTHQUAKE; DAMAGE; MODEL; SEPARATION; VIBRATION; INERTER; DESIGN;
D O I
10.1016/j.soildyn.2024.109036
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Today, population growth and the need for constructing adjacent buildings have raised the likelihood of pounding between adjacent buildings with different dynamic characteristics. The pounding force applied to adjacent buildings during an earthquake is intensive and may cause total or partial damage to structural elements, leading to collapse. It disturbs and complicates the functioning of buildings during and after an earthquake. Therefore, the main aim of this paper is to minimize and, if possible, eliminate the pounding force between two adjacent structures by considering three objective functions. For this aim, the tuned mass damper is utilized here. Also, this paper aims to reduce the number of collisions between different stories of adjacent buildings through a tuned mass damper system. For this purpose, two adjacent steel moment frames with six and ten stories are nonlinearly modeled and validated using the concentrated plasticity model in OpenSees. Moreover, the pounding element is nonlinearly modeled and validated. Then, tuned mass dampers (TMDs) are used on the roofs of the structures. They are optimized in stiffness, mass, and damping coefficient using the grey wolf optimization (GWO) algorithm. Nonlinear time history analysis (NLTHA) is performed under nine far- and near- field earthquakes. The pounding force and structural responses are analyzed, including maximum story acceleration, maximum inter-story drift, and base shear in the TMD-controlled and uncontrolled adjacent buildings. Finally, the Park-Ang damage index is evaluated for the structures with and without the TMD system. It has been found that the maximum pounding force, the maximum acceleration of the stories, the base shear, the drift ratio, and the number of collisions significantly reduce (or omit) in the presence of TMDs when the objective function is considered to be the minimization of the maximum pounding force. It is shown that the maximum pounding force generally declines to zero for this objective function.
引用
收藏
页数:25
相关论文
共 50 条
  • [1] Optimal design and performance assessment of multiple tuned mass damper inerters to mitigate seismic pounding of adjacent buildings
    Djerouni, Salah
    Elias, Said
    Abdeddaim, Mahdi
    Rupakhety, Rajesh
    JOURNAL OF BUILDING ENGINEERING, 2022, 48
  • [2] Effectiveness of Optimal Shared Multiple Tuned Mass Damper Inerters for Pounding Mitigation of Adjacent Buildings
    Djerouni, Salah
    Elias, Said
    Abdeddaim, Mahdi
    De Domenico, Dario
    PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2023, 28 (01)
  • [3] Analysis of seismic pounding between adjacent buildings
    Hao, Hong
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2015, 16 (03) : 208 - 225
  • [4] Evaluation of a pendulum pounding tuned mass damper for seismic control of structures
    Wang, Wenxi
    Yang, Zhilin
    Hua, Xugang
    Chen, Zhengqing
    Wang, Xiuyong
    Song, Gangbing
    ENGINEERING STRUCTURES, 2021, 228
  • [5] Seismic response reduction using a tuned pendulum pounding mass damper: Experimental verification of superior performance
    Aly, Aly Mousaad
    Chapain, Suvash
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2023, 173
  • [6] Optimization of Tuned Mass Damper for Adjacent Buildings with Equal Properties
    Bekdas, Gebrail
    Nigdeli, Sinan Melih
    11TH INTERNATIONAL CONFERENCE OF NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2013, PTS 1 AND 2 (ICNAAM 2013), 2013, 1558 : 429 - 432
  • [7] Control of Adjacent Buildings Using Shared Tuned Mass Damper
    Guenidi, Z.
    Abdeddaim, M.
    Ounis, A.
    Shrimali, M. K.
    Datta, T. K.
    X INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS (EURODYN 2017), 2017, 199 : 1568 - 1573
  • [8] Seismic pounding between adjacent buildings of unequal floor height
    Zou, Lihua
    Li, Liangfeng
    Huang, Jianqiang
    Huang, Kai
    JOURNAL OF VIBROENGINEERING, 2014, 16 (06) : 2756 - 2767
  • [9] Use of a shared tuned mass damper (STMD) to reduce vibration and pounding in adjacent structures
    Abdullah, MM
    Hanif, JH
    Richardson, A
    Sobanjo, J
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2001, 30 (08): : 1185 - 1201
  • [10] Seismic response of adjacent buildings with similar or different dynamic characteristics
    Athanassiadou, Christina J.
    Penelis, George G.
    Kappos, Andreas J.
    Earthquake Spectra, 1994, 10 (02)