Advancing elemental analysis by collision/reaction cell technology and micro-droplet calibration for bioimaging applications by LA-ICP-TOFMS

被引:0
|
作者
Theiner, Sarah [1 ]
Foels, Elisabeth [1 ,2 ]
Koellensperger, Gunda [1 ]
机构
[1] Univ Vienna, Inst Analyt Chem, Fac Chem, Waehringer Str 38, A-1090 Vienna, Austria
[2] Univ Vienna, Vienna Doctoral Sch Chem DoSChem, Waehringer Str 42, A-1090 Vienna, Austria
关键词
Bioimaging; LA-ICP-TOFMS; Collision/reaction cell; Micro-droplet calibration; MASS-SPECTROMETRY; ABLATION; RESOLUTION; STANDARDS; DESIGN; TISSUE; MS;
D O I
10.1016/j.aca.2024.343345
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Bioimaging applications by laser ablation inductively coupled plasma time-of-flight mass spectrometry (LA-ICP-TOFMS) require comprehensive elemental analysis spanning the entire mass range. Within biological systems, endogenous elements are critical for maintaining metal homeostasis in cells, a fundamental aspect in disease progression when disrupted. Additionally, elements from the higher mass range may originate from various sources such as metal-tags for immuno-mass spectrometry, nanoparticles, or metal-based anticancer drugs. This study assesses the efficacy of collision/reacton cell (CCT) mode for simultaneously analysing elements across the complete mass spectrum. Furthermore, we demonstrate the accuracy of the LA-ICP-TOFMS methodology through the analysis of serum reference material. Results: Our findings demonstrate that the CCT mode outperforms the standard/no gas mode for LA-ICP-TOFMS measurements, particularly in quantifying endogenous elements susceptible to interferences. Through the analysis of picolitre-volume micro-droplet standards and serum reference material (deposited as micro-droplets), we observed accurate quantification of elements such as iron and selenium, with isotope ratios closely resembling natural compositions. As key advantage, the utilization of the CCT mode eliminated the need for labor-intensive post-data processing, streamlining analytical procedures. Additionally, the CCT mode also provided enhanced sensitivity (factor of 1.5-2) for elements in the higher mass range compared to the standard mode, without compromising the sensitivity for endogenous elements. Significance: We successfully integrated Seronorm serum reference material-containing micro-droplets into LAICPMS bioimaging workflows for quality control, enabling validated measurements of key biological elements. The use of the CCT mode is highly recommended for bioimaging applications that address the analysis of elements across the entire mass range.
引用
收藏
页数:6
相关论文
共 4 条
  • [1] Micro-droplet-based calibration for quantitative elemental bioimaging by LA-ICPMS
    Andreas Schweikert
    Sarah Theiner
    Debora Wernitznig
    Anna Schoeberl
    Martin Schaier
    Sophie Neumayer
    Bernhard K. Keppler
    Gunda Koellensperger
    Analytical and Bioanalytical Chemistry, 2022, 414 : 485 - 495
  • [2] Micro-droplet-based calibration for quantitative elemental bioimaging by LA-ICPMS
    Schweikert, Andreas
    Theiner, Sarah
    Wernitznig, Debora
    Schoeberl, Anna
    Schaier, Martin
    Neumayer, Sophie
    Keppler, Bernhard K.
    Koellensperger, Gunda
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (01) : 485 - 495
  • [3] Semiquantitative Analysis for High-Speed Mapping Applications of Biological Samples Using LA-ICP-TOFMS
    Metarapi, Dino
    Schweikert, Andreas
    Jerse, Ana
    Schaier, Martin
    Elteren, Johannes T. van
    Koellensperger, Gunda
    Theiner, Sarah
    Sala, Martin
    ANALYTICAL CHEMISTRY, 2023, 95 (19) : 7804 - 7812
  • [4] Radionuclide analysis using collision-reaction cell ICP-MS technology: a review
    Diez-Fernandez, Silvia
    Isnard, Helene
    Nonell, Anthony
    Bresson, Carole
    Chartier, Frederic
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2020, 35 (12) : 2793 - 2819