Evaluation of Motion-Synchronized Helical Tomotherapy Treatments for Intrafraction Respiratory Motion

被引:0
|
作者
Ferris, William S. [1 ]
机构
[1] The University of Wisconsin - Madison
关键词
Compilation and indexing terms; Copyright 2024 Elsevier Inc;
D O I
暂无
中图分类号
学科分类号
摘要
Dosimetry - Quality assurance - Radiotherapy - Synchronization
引用
收藏
相关论文
共 50 条
  • [1] Fiducial visibility on planar images during motion-synchronized tomotherapy treatments
    Ferris, William S.
    DeWerd, Larry A.
    Culberson, Wesley S.
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (02)
  • [2] Tracking target/chest relationship changes during motion-synchronized tomotherapy treatments
    Ferris, William S.
    Culberson, Wesley S.
    Bayouth, John E.
    [J]. MEDICAL PHYSICS, 2022, 49 (06) : 3990 - 3998
  • [3] Performance evaluation of respiratory motion-synchronized dynamic IMRT delivery
    Yoganathan, S. A.
    Das, K. J. Maria
    Agarwal, Arpita
    Kumar, Shaleen
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (03): : 39 - 51
  • [4] Correlation between dosimetric effect and intrafraction motion during prostate treatments delivered with helical tomotherapy
    Langen, Katja M.
    Lu, Weiguo
    Ngwa, Wilfred
    Willoughby, Twyla R.
    Chauhan, Bhavin
    Meeks, Sanford L.
    Kupelian, Patrick A.
    Olivera, Gustavo
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24): : 7073 - 7086
  • [5] Impact Or No Impact of Respiratory Motion On Helical Tomotherapy Dose
    Ngwa, W.
    Shah, A.
    Meeks, S.
    Kupelian, P.
    Langen, K.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [6] Respiratory motion effects on whole breast helical tomotherapy
    Moeckly, Steven R.
    Lamba, Michael
    Elson, Howard R.
    [J]. MEDICAL PHYSICS, 2008, 35 (04) : 1464 - 1475
  • [7] Impact of Respiratory Motion in Lung SBRT With Helical Tomotherapy
    Sun, S. X.
    Liu, A.
    Chen, Y. J.
    Smith, D. D.
    Han, C.
    Dandapani, S. V.
    Schultheiss, T. E.
    Wong, J. Y. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E424 - E424
  • [8] Correlation of Delivery Reproducibility With Anatomical Modifications and Intrafraction Motion During Treatments Using Helical Tomotherapy (HT)-Integrated Detectors
    Cagni, E.
    Botti, A.
    Mezzenga, E.
    D'errico, V.
    Ciammella, P.
    Iori, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S813 - S814
  • [9] Intrafraction motion in noninvasive image-guided stereotactic radiosurgery using helical tomotherapy
    Chase, D
    Bowling, I
    Rodríguez, E
    Ramsey, C
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1825 - 1825
  • [10] Evaluation of the intrafraction motion in SRT-SRS treatments
    Granero Cabanero, D.
    Almendros Blanco, P.
    Hernandez Machancoses, A.
    Vicedo Gonzalez, A.
    Garcia Hernandez, T.
    Brualla Gonzalez, L.
    Perruca Salvador, F.
    Salvador Montano, A.
    Rosello Ferrando, J.
    Lopez Torrecilla, J.