Simple and sensitive method for in vitro monitoring of red blood cell viscoelasticity by Quartz Crystal Microbalance with dissipation monitoring (QCM-D)

被引:0
|
作者
Palleschi, Simonetta [1 ]
Silvestroni, Leopoldo [2 ]
Rossi, Barbara [1 ]
Dinarelli, Simone [3 ]
Magi, Marco [2 ]
Giacomelli, Lorenzo [2 ]
Bettucci, Andrea [2 ]
机构
[1] Department of Environment and Health, Istituto Superiore di Sanità, Viale Regina Elena 299, Rome,00161, Italy
[2] Department of Basic and Applied Sciences for Engineering, Sapienza University of Rome, Via A. Scarpa 16, Rome,00161, Italy
[3] Institute for the Structure of Matter, Consiglio Nazionale delle Ricerche, Via del Fosso del Cavaliere 100, Rome,00133, Italy
来源
关键词
Acoustic waves - Shear flow - Shear strain;
D O I
10.1016/j.biosx.2024.100554
中图分类号
学科分类号
摘要
Viscoelasticity (VE) is the intrinsic mechano-dynamic property enabling red blood cells (RBCs) to undergo prompt and repeated deformations while maintaining structural integrity. Assessing RBC VE and how different stressors can affect it is of great interest. Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) is a technology exploiting high-frequency acoustic waves to probe soft matter rheological properties. In the present study, a QCM-D method is reported for in vitro monitoring of cell VE in viable RBCs. The method is based on casting a sensor-adherent cell monolayer and modeling it as an effective viscoelastic medium, and allows to extrapolate proxy values of both the elastic and the viscous cell shear moduli. Real-time VE changes induced by the known cell VE stressors temperature, medium tonicity, glutaraldehyde, methyl-β-cyclodextrin and cytochalasin D have been reliably identified. The method is relatively simple and inexpensive, non-invasive, and able to seize subtle changes of cell biomechanics. Hence, it could be usefully exploited for in vitro assessment of RBC rheological properties and their alterations induced by external chemico-physical stimuli. © 2024
引用
收藏
相关论文
共 50 条
  • [1] Applications of the QCM-D method (quartz crystal microbalance with dissipation monitoring) to solid-liquid interface
    Kasemo, Bengt H.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [2] Adsorption of pectins and their enzymatic degradation probed by a quartz crystal microbalance with dissipation monitoring (QCM-D)
    Zhang, Xiao
    Roman, Maren
    Esker, Alan R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [3] Protein Adsorption Behaviors on PLLA Surface Studied by Quartz Crystal Microbalance with Dissipation Monitoring (QCM-D)
    Zeng, Rong
    Zhang, Yi
    Tu, Mei
    Zhou, Changren
    MATERIALS RESEARCH, PTS 1 AND 2, 2009, 610-613 : 1219 - 1223
  • [4] Rapid Assessment of Glass Etching/Corrosion using the Quartz Crystal Microbalance with Dissipation Monitoring, QCM-D
    Macakova, Lubica
    Kjellin, Mikael
    Andersson, Martin
    Lof, Leif
    Wnukowska, Halina
    TENSIDE SURFACTANTS DETERGENTS, 2014, 51 (06) : 484 - 490
  • [5] Using quartz crystal microbalance with dissipation monitoring (QCM-D) to predict antimicrobial peptide action on membranes
    Wang, Kathleen F.
    Nagarajan, Ramanathan
    Mello, Charlene
    Camesano, Terri A.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240
  • [6] Enzymatic degradation of model lignin thin films probed by quartz crystal microbalance with dissipation monitoring (QCM-D)
    Wang, Chao
    Esker, Alan R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [7] Interactions between monolignols and model cellulose surfaces probed by quartz crystal microbalance with dissipation monitoring (QCM-D)
    Wang, Chao
    Qian, Chen
    Jiang, Feng
    Maren, Roman
    Esker, Alan R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [8] Adsorption of Naphthenic Acids onto Mineral Surfaces Studied by Quartz Crystal Microbalance with Dissipation Monitoring (QCM-D)
    Kelesoglu, Serkan
    Volden, Sondre
    Kes, Murside
    Sjoblom, Johan
    ENERGY & FUELS, 2012, 26 (08) : 5060 - 5068
  • [9] Comparison of membrane fouling during ultrafiltration with adsorption studied by quartz crystal microbalance with dissipation monitoring (QCM-D)
    Rudolph-Schopping, Gregor
    Schagerlof, Herje
    Jonsson, Ann-Sofi
    Lipnizki, Frank
    JOURNAL OF MEMBRANE SCIENCE, 2023, 672
  • [10] Tannin-on-protein adlayers: Secondary adsorption quantified by quartz crystal microbalance with dissipation monitoring (QCM-D)
    Larcinese-Hafner, Valeria
    Erni, Philipp
    FOOD HYDROCOLLOIDS, 2024, 157