Mitigating adverse effects of Cu-containing intrauterine devices using a highly biocompatible Cu-5Fe alloy

被引:0
|
作者
Yang, Lijun [1 ,2 ]
Bao, Guo [2 ]
Yao, Cancan [1 ]
Diao, Tian [1 ]
Su, Zhenning [1 ]
Liu, Tingting [1 ]
Li, Guannan [3 ]
Wang, Gonglei [4 ]
Chen, Xihua [2 ]
Xu, Xiangbo [1 ,2 ]
Sun, Bing [5 ]
Xu, Xiaoxue [4 ]
He, Bin [1 ,2 ]
Zheng, Yufeng [1 ,3 ]
机构
[1] Peking Union Med Coll, Grad Sch, Beijing 100730, Peoples R China
[2] Natl Res Inst Family Planning, Dept Reprod & Physiol, NHC Key Lab Reprod Hlth Engn Technol Res, Beijing 100081, Peoples R China
[3] Peking Univ, Sch Mat Sci & Engn, Beijing 100871, Peoples R China
[4] Univ Technol Sydney, Fac Engn & Informat Technol, Sch Biomed Engn, Ultimo, NSW 2007, Australia
[5] Univ Technol Sydney, Fac Sci, Ctr Clean Energy Technol, Sch Math & Phys Sci, Ultimo, NSW 2007, Australia
基金
中国国家自然科学基金;
关键词
Cu-Fe alloys; Burst release; Copper-containing intrauterine devices; Biocompatibility; Contraception; ION BURST RELEASE; CORROSION BEHAVIOR; COPPER CORROSION; EFFECTIVE INHIBITION; CU/LDPE COMPOSITE; METALLIC COPPER; IUD; INDOMETHACIN; NICKEL;
D O I
10.1016/j.actbio.2024.09.022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Copper-containing intrauterine devices (Cu-IUD) are adopted by worldwide women for contraception with the advantages of long-term effectiveness, reversibility and affordability. However, adverse effects occur in the initial implantation stage of Cu-IUD in uterine because of the burst release of Cu2 + . To minimize the burst release, in this study, we designed a series of Cu-Fe alloys with 0.5 wt%, 1 wt% and 5 wt% Fe and also further produced ultrafine grained (UFG) structure for these alloys via equal-channel angular pressing. The microstructures and properties of the coarse grained (CG) Cu, CG Cu-Fe alloys and UFG Cu-Fe alloys were systematically investigated, including grain structure and phase compositions, metallic ions release behavior, electrochemical corrosion performance, and in vitro cytotoxicity. With careful comparison and selection, we chose the CG Cu-5Fe and UFG Cu-5Fe for in vivo tests using rat model, including tissue biocompatibility, in vivo corrosion behavior, and contraceptive effectiveness. Moreover, the corrosion mechanism of the Cu-5Fe alloy and its improved biocompatibility was discussed. Both CG and UFG Cu-5Fe alloys exhibited dramatic suppression of Cu2 + release in simulated uterine fluid for the long-term immersion process. The in vivo tissue compatibility was significantly improved with both CG and UFG Cu-5Fe alloys implanted in the rats' uterine while the high contraceptive efficacy was well maintained. Due to the superior biocompatibility, the CG and UFG Cu-5Fe alloys can be the promising candidate material for Cu-IUD.
引用
收藏
页码:651 / 667
页数:17
相关论文
共 16 条
  • [1] Influences of Sn on Fe phase segregation and properties of Cu-5Fe alloy
    Luo, Xin
    Wang, Lanhao
    Yuan, Dawei
    Liu, Zhenxia
    Wang, Hang
    Xiao, Xiangpeng
    Chen, Hui Ming
    Guo, Chengjun
    Yang, Bin
    MATERIALS SCIENCE AND TECHNOLOGY, 2023, 39 (15) : 2191 - 2204
  • [2] Partial Oxidation of Ethane to Oxygenates Using Fe- and Cu-Containing ZSM-5
    Forde, Michael M.
    Armstrong, Robert D.
    Hammond, Ceri
    He, Qian
    Jenkins, Robert L.
    Kondrat, Simon A.
    Dimitratos, Nikolaos
    Lopez-Sanchez, Jose Antonio
    Taylor, Stuart H.
    Willock, David
    Kiely, Christopher J.
    Hutchings, Graham John
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2013, 135 (30) : 11087 - 11099
  • [3] Effect of the rare earth element Ce on the microstructure, properties and thermal stability of Cu-5Fe alloy
    Luo, Xin
    Zeng, Hao
    Yuan, Dawei
    Liu, Zhenxia
    Xiao, Xiangpeng
    Chen, Huiming
    Guo, Chengjun
    Yang, Bin
    MATERIALS TODAY COMMUNICATIONS, 2023, 36
  • [4] Investigation of a new phase in Cu-containing Fe-Ni alloy for corrosion resistance behavior
    Li, Chunyan
    Li, Baozeng
    Wang, Yingmin
    Shi, Yong
    Dong, Chuang
    INTEGRATED FERROELECTRICS, 2016, 172 (01) : 59 - 65
  • [5] Comparison of precipitation kinetics and strengthening in an Fe-0.8%Cu alloy and a 0.8 % Cu-containing low-carbon steel
    Deschamps, A
    Militzer, M
    Poole, WJ
    ISIJ INTERNATIONAL, 2003, 43 (11) : 1826 - 1832
  • [6] Effective easing of the side effects of copper intrauterine devices using ultra-fine-grained Cu-0.4Mg alloy
    Fan, Qianqian
    Bao, Guo
    Ge, Dongfeng
    Wang, Kun
    Sun, Mingming
    Liu, Tingting
    Liu, Jianing
    Zhang, Zechuan
    Xu, Xiangbo
    Xu, Xiaoxue
    He, Bin
    Rao, Jiancun
    Zheng, Yufeng
    ACTA BIOMATERIALIA, 2021, 128 : 523 - 539
  • [7] FATIGUE OF AN FE-1-5 PERCENT CU ALLOY CONTAINING STABLE, NON-COHERENT PRECIPITATE PARTICLES
    MCGRATH, JT
    BRATINA, WJ
    PHILOSOPHICAL MAGAZINE, 1970, 21 (173): : 1087 - &
  • [8] Effects of cobalt and solidification cooling rate on intermetallic phases and tensile properties of a -Cu, -Zn, -Fe containing Al-Si alloy
    Xavier, Marcella G. C.
    Souza, Thaisa M. G.
    Cheung, Noe
    Garcia, Amauri
    Spinelli, Jose E.
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2020, 107 (1-2): : 717 - 730
  • [9] Effects of cobalt and solidification cooling rate on intermetallic phases and tensile properties of a -Cu, -Zn, -Fe containing Al-Si alloy
    Marcella G. C. Xavier
    Thaisa M. G. Souza
    Noé Cheung
    Amauri Garcia
    José E. Spinelli
    The International Journal of Advanced Manufacturing Technology, 2020, 107 : 717 - 730
  • [10] Nanotwins-containing microstructure and superior mechanical strength of a Cu-9A1-5Fe-5Ni alloy additively manufactured by laser metal deposition
    Li, Boyuan
    Zheng, Han
    Han, Changjun
    Zhou, Kun
    ADDITIVE MANUFACTURING, 2021, 39