Development of a Compact NDIR CO2 Gas Sensor for a Portable Gas Analyzer

被引:0
|
作者
Xu, Maosen [1 ,2 ,3 ]
Tian, Wei [3 ]
Lin, Yuzhe [3 ]
Xu, Yan [1 ,2 ]
Tao, Jifang [3 ]
机构
[1] Shandong Univ Sci & Technol, Coll Elect Engn & Automat, Qingdao 266590, Peoples R China
[2] Shandong Univ Sci & Technol, Coll Elect & Informat Engn, Qingdao 266590, Peoples R China
[3] Shandong Univ, Sch Informat Sci & Engn ISE, Qingdao 266237, Peoples R China
关键词
CO2; sensor; NDIR; MEMS emitter; air quality monitoring; CARBON-DIOXIDE; SURFACE-ROUGHNESS; TEMPERATURE;
D O I
10.3390/mi15101203
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon dioxide (CO2) gas sensor based on non-dispersive infrared (NDIR) technology has been developed and is suitable for use in portable devices for high-precision CO2 detection. The NDIR gas sensor comprises a MEMS infrared emitter, a MEMS thermopile detector with an integrated optical filter, and a compact gas cell with high optical coupling efficiency. A dual-ellipsoid mirror optical system was designed, and based on optical simulation analysis, the structure of the dual-ellipsoid reflective gas chamber was designed and optimized, achieving a coupling efficiency of up to 54%. Optical and thermal simulations were conducted to design the sensor structure, considering thermal management and light analysis. By optimizing the gas cell structure and conditioning circuit, we effectively reduced the sensor's baseline noise, enhancing the overall reliability and stability of the system. The sensor's dimensions were 20 mm x 10 mm x 4 mm (L x W x H), only 15% of the size of traditional NDIR gas sensors with equivalent detection resolution. The developed sensor offers high sensitivity and low noise, with a sensitivity of 15 mu V/ppm, a detection limit of 90 ppm, and a resolution of 30 ppm. The total power consumption of the whole sensor system is 6.5 mW, with a maximum power consumption of only 90 mW.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Development of a compact NDIR CO2 gas sensor for harsh environments
    Xu, Maosen
    Xu, Yan
    Tao, Jifang
    Wen, Lianggong
    Zheng, Chunhong
    Yu, Zeping
    He, Shuaibin
    INFRARED PHYSICS & TECHNOLOGY, 2024, 136
  • [2] NDIR CO2 gas sensor with improved temperature compensation
    Park, JongSeon
    Cho, HeeChan
    Yi, SeungHwan
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 303 - 306
  • [3] Temperature compensation of novel NDIR CO2 gas sensor
    Yi, SeungHwan
    Park, JongSeon
    Park, JeongMin
    2006 IEEE SENSORS, VOLS 1-3, 2006, : 1373 - +
  • [4] Self-temperature compensation of NDIR CO2 gas sensor
    Park, JongSeon
    Cho, HeeChan
    Yi, SeungHwan
    PROCEEDINGS OF THE FOURTH IASTED INTERNATIONAL CONFERENCE ON CIRCUITS, SIGNALS, AND SYSTEMS, 2006, : 220 - +
  • [5] Breakthrough in CO2 Measurement With a Chamberless NDIR Optical Gas Sensor
    Vafaei, Mostafa
    Amini, Amir
    Siadatan, Alireza
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (05) : 2258 - 2268
  • [6] A high-precision NDIR CO2 gas sensor for automotive applications
    Frodl, Robert
    Tille, Thomas
    IEEE SENSORS JOURNAL, 2006, 6 (06) : 1697 - 1705
  • [7] The development system of portable of CO2 non-dispersive infrared detector gas analyzer
    Yeh, T
    TECHNICAL DIGEST OF THE SEVENTH INTERNATIONAL MEETING ON CHEMICAL SENSORS, 1998, : 675 - 685
  • [8] Comparison of the Characteristics of Small Commercial NDIR CO2 Sensor Models and Development of a Portable CO2 Measurement Device
    Yasuda, Tomomi
    Yonemura, Seiichiro
    Tani, Akira
    SENSORS, 2012, 12 (03): : 3641 - 3655
  • [9] Development of a CO2 gas analyzer for monitoring soil CO2 concentrations
    Yasuda, Yukio
    Ohtani, Yoshikazu
    Mizoguchi, Yasuko
    Nakamura, Tsuyoshi
    Miyahara, Hideyuki
    JOURNAL OF FOREST RESEARCH, 2008, 13 (05) : 320 - 325
  • [10] Development of a coulometric CO2 gas sensor
    Trapp, T
    Ross, B
    Cammann, K
    Schirmer, E
    Berthold, C
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 50 (02) : 97 - 103