Investigating the Effect of Motion Capture Suits on the Test-Retest Reliability of Gait Parameters

被引:0
|
作者
Smith, Matt C. [1 ]
Leveridge, Phaedra [2 ]
Massey, Garry [2 ]
Tyrrell, Jessica [3 ]
Hilton, Malcolm [4 ]
Williams, Genevieve K. R. [2 ]
机构
[1] Univ Exeter, Med Sch, Dept Biomed & Clin Sci, Publ Hlth & Sports Sci Dept, Exeter EX1 2HZ, England
[2] Univ Exeter, Publ Hlth & Sports Sci Dept, Med Sch, Exeter EX1 2HZ, England
[3] Univ Exeter, Fac Hlth & Life Sci, Coll Biomed & Clin Sci, Genet Complex Traits, Exeter EX4 4QJ, England
[4] Univ Exeter, Med Sch, Clin & Biomed Sci, Exeter EX1 2LU, England
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 18期
关键词
motion capture; intraclass correlation; minimal detectable change; gait analysis; clinical biomechanics; KINEMATICS; FOOTWEAR; HIP;
D O I
10.3390/app14188570
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
When collecting marker-based motion capture data from clinical populations, speed of collection and comfort for the participant is a priority. This could be achieved by attaching markers to motion capture Velcro suits, as opposed to the skin. This study aimed to ascertain the reliability of sagittal-plane gait parameters estimated using Plug-in Gait (PiG) and Conventional Gait Model 2 (CGM2) marker sets from data collected in Suited and Non-suited (markers placed onto skin) conditions. For ten participants, markers were placed based on PiG and CGM2 models and data captured during a 2-min treadmill walk. Trials were repeated in suited and non-suited conditions. PiG ankle flexion/extension measurements had poor/moderate reliability (Non-suited ICC = 0.531, Suited ICC = 0.435). CGM2 ankle flexion/extension measurements had good/excellent reliability (Non-suited ICC = 0.916, Suited ICC = 0.900). There were significant differences in minimal detectable change (MDC) between conditions at the ankle for PiG (Non-suited MDC = 2.32 degrees, Suited MDC = 18.90 degrees), but not for CGM2 (Non-suited MDC = 0.63 degrees, Suited MDC = 0.95 degrees). When using CGM2, knee (Non-suited ICC = 0.878, Suited ICC = 0.855) and hip (Non-suited ICC = 0.897, Suited ICC = 0.948) showed good/excellent reliability in both conditions. A motion capture suit is not a reliable solution when collecting joint angle data using the PiG model but is reliable enough to consider when using the CGM2 model.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Test-Retest Reliability of Discrete Gait Parameters in Children With Cerebral Palsy
    Klejman, Susan
    Andrysek, Jan
    Dupuis, Annie
    Wright, Virginia
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (05): : 781 - 787
  • [2] Exploring The Test-retest Reliability Of Markerless Motion Capture For Outdoor Walking
    Hills, Hunter
    James, Darren
    Litwiller, Sydney
    Taylor, J. B.
    Ford, K. R.
    Pexa, B. S.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 989 - 989
  • [3] Test-Retest Reliability of the MotionMetrix Software for the Analysis of Walking and Running Gait Parameters
    Jaen-Carrillo, Diego
    Ruiz-Alias, Santiago A.
    Chicano-Gutierrez, Jose M.
    Ruiz-Malagon, Emilio J.
    Roche-Seruendo, Luis E.
    Garcia-Pinillos, Felipe
    SENSORS, 2022, 22 (09)
  • [4] Test-Retest Reliability of Performance Scores Using a Markerless Motion Capture System
    Mosier, Eric M.
    Fry, Andrew C.
    Nicoll, Justin X.
    Cabarkapa, Dimitrije
    Sontag, Stephanie A.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2019, 51 (06): : 61 - 61
  • [5] Test-Retest Reliability of the Effect of Prism on Gait Utilizing GaitRite Technology
    Yevseyenkov, Vladimir
    Frison, Kaitlin
    Wood, Mark
    Harrison, Wendy Watkins
    Scott, Jeffrey
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [6] Test-retest reliability of trunk accelerometric gait analysis
    Henriksen, M
    Lund, H
    Moe-Nilssen, R
    Bliddal, H
    Danneskiod-Samsoe, B
    GAIT & POSTURE, 2004, 19 (03) : 288 - 297
  • [7] Test-retest reliability of reinforcement learning parameters
    Schaaf, Jessica V.
    Weidinger, Laura
    Molleman, Lucas
    van den Bos, Wouter
    BEHAVIOR RESEARCH METHODS, 2024, 56 (05) : 4582 - 4599
  • [8] TEST-RETEST RELIABILITY OF SPECTRAL PARAMETERS OF THE EEG
    GASSER, T
    BACHER, P
    STEINBERG, H
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 60 (04): : 312 - 319
  • [9] Test-retest reliability of spatial and temporal gait parameters of people with Alzheimer's disease
    Wittwer, Joanne E.
    Webster, Kate E.
    Andrews, Peta T.
    Menz, Hylton B.
    GAIT & POSTURE, 2008, 28 (03) : 392 - 396
  • [10] Test-Retest Reliability of the Total Motion Release® Scale
    Miley, Emilie N.
    Reeves, Ashley J.
    Casanova, Madeline P.
    Martonick, Nickolai J. P.
    Baker, Jayme
    Baker, Russell T.
    JOURNAL OF SPORT REHABILITATION, 2021, 30 (06) : 961 - 964