Removal of metals and assimilable organic carbon by activated carbon and reverse osmosis point-of-use water filtration systems

被引:1
|
作者
Yu, Hsin-Yin [1 ]
Gupta, Shreya [2 ]
Zhou, Zhi [1 ,2 ]
机构
[1] Environmental and Ecological Engineering, Purdue University, West Lafayette,IN,47907, United States
[2] Civil and Construction Engineering, Purdue University, West Lafayette,IN,47907, United States
关键词
Activated carbon treatment - Iron removal (water treatment) - Reverse osmosis - Water filtration;
D O I
10.1016/j.chemosphere.2024.143251
中图分类号
学科分类号
摘要
Activated carbon (AC) systems and reverse osmosis (RO) systems are commonly used point-of-use (POU) water filtration systems for removing trace-level contaminants in tap water to protect human health. However, limited research has been done to evaluate their effectiveness in removing heavy metals like manganese (Mn) and uranium (U), or to assess the potential for undesired microbial growth within POU systems, which can reduce their treatment efficiency. This study aimed to systematically evaluate the removal of metals and assimilable organic carbon (AOC) in POU systems. AC systems were operated to 200% of their designed treatment capacities and RO systems were run for three weeks. The results showed that AC systems were generally ineffective at removing metals from drinking water, while RO systems effectively removed them. Both Mn and U were poorly removed by AC systems. Calcium (Ca) and magnesium (Mg) were poorly removed by AC systems, with efficiencies of less than 1%. Iron (Fe) removal by AC systems varied between 61% and 84%. Copper (Fe), likely due to its low influent concentration (−1), was effectively removed by AC systems with efficiencies over 95%. In contrast, RO systems consistently removed all metals effectively. Mn and U removal in RO systems exceeded 95%, while Ca, Mn, Fe, and Cu were all removed with efficiencies greater than 98%. AOC was effectively removed from all AC and RO systems, but with high variability in removal efficiency, which is likely attributed to the heterogeneity of biofilm and microbial growth within the POU systems. The new knowledge generated from this study can improve our understanding of chemical contaminant removal in POU systems and inform the development of better strategies for designing and operating POU systems to remove chemical contaminants in drinking water and mitigate their associated health risks. © 2024 Elsevier Ltd
引用
收藏
相关论文
共 50 条
  • [1] Removal of assimilable organic carbon and biodegradable dissolved organic carbon by reverse osmosis and nanofiltration membranes
    Escobar, IC
    Hong, SK
    Randall, AA
    JOURNAL OF MEMBRANE SCIENCE, 2000, 175 (01) : 1 - 17
  • [2] Microbial filtration utilizing carbon block, reverse osmosis and other point-of-use membrane technologies
    Buteyn, John
    Hatch, Gary
    Kinsey, Melissa
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 659 - 659
  • [3] Nanoenabling activated carbon based point-of-use water filtration devices for added functionality
    Atkinson, Ariel
    Lee, Heuidae
    Markovski, Jasmina
    Brown, Frank
    Nys, Dillon
    Ashani, Harsh
    Sinha, Shahnawaz
    Westerhoff, Paul
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [4] Removal of bromate and assimilable organic carbon from drinking water using granular activated carbon
    Huang, WJ
    Peng, HS
    Peng, MY
    Chen, LY
    WATER SCIENCE AND TECHNOLOGY, 2004, 50 (08) : 73 - 80
  • [5] Reverse osmosis followed by activated carbon filtration for efficient removal of organic micropollutants from river bank filtrate
    Kegel, F. Schoonenberg
    Rietman, B. M.
    Verliefde, A. R. D.
    WATER SCIENCE AND TECHNOLOGY, 2010, 61 (10) : 2603 - 2610
  • [6] Commercial reverse osmosis point-of-use systems in Egypt failed to purify tap water
    Gad, Mahmoud
    Marouf, Mohamed A.
    Abogbal, Amr
    Hu, Anyi
    Noura, N.
    JOURNAL OF WATER AND HEALTH, 2024, 22 (05) : 905 - 922
  • [7] Bioluminescence-Based Method for Measuring Assimilable Organic Carbon in Pretreatment Water for Reverse Osmosis Membrane Desalination
    Weinrich, Lauren A.
    Schneider, Orren D.
    LeChevallier, Mark W.
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2011, 77 (03) : 1148 - 1150
  • [8] The use of biological activated carbon filtration for the removal of natural organic matter and organic micropollutants from water
    van der Hoek, JP
    Hofman, JAMH
    Graveland, A
    WATER SCIENCE AND TECHNOLOGY, 1999, 40 (09) : 257 - 264
  • [9] Use of Biological Activated Carbon Filtration for the removal of natural organic matter and organic micropollutants from water
    van, der Hoek, J.P.
    Hofman, J.A.M.H.
    Graveland, A.
    Water Science and Technology, 40 (09): : 257 - 264
  • [10] Contribution of assimilable organic carbon to biological fouling in seawater reverse osmosis membrane treatment
    Weinrich, Lauren
    LeChevallier, Mark
    Haas, Charles N.
    WATER RESEARCH, 2016, 101 : 203 - 213