Influence of Household Heat Pump Air Conditioner Air Supply Modes on Thermal Comfort

被引:0
|
作者
Dong M. [1 ,2 ]
Tan J. [1 ,2 ]
Xiao B. [1 ,2 ]
Li B. [1 ,2 ]
Zhao S. [1 ,2 ]
机构
[1] State Key Laboratory of Air-conditioning Equipment and System Energy Conservation, Zhuhai
[2] GREE Electric Appliances Inc of Zhuhai, Zhuhai
关键词
Air supply modes; Indoor thermal environment; Thermal comfort; Thermal sensation;
D O I
10.16339/j.cnki.hdxbzkb.2022020
中图分类号
学科分类号
摘要
In order to study the influence of household heat pump air conditioner air supply modes on thermal comfort, the environmental parameters, as well as 15 subjects' thermal sensation and thermal comfort, were investigated under the air supply modes of medium air supply, down air supply and distributed air supply in the artificial environment laboratory. The results show that when the initial background temperature is 0 ℃, the air temperature around all human body parts can be increased quickly and evenly by the distributed air supply mode, and the overall thermal sensation and the overall thermal comfort of the subjects rise fastest, so the thermal comfort of the subject has a significant improvement. After the indoor thermal environment is stable, the temperature evenness of the distributed air supply is the minimum of 1.9 ℃, which makes the subjects in the air supply area feel warm, the local thermal sensation difference is the smallest, and the subjects in the other places do not feel cold. The fitting results of steady-state local thermal sensation and overall thermal comfort show that the thermal sensation of the feet has a significant effect on the overall thermal comfort, the vertical air temperature difference of the distributed air supply and down air supply is less than 3 ℃, and the thermal sensation of feet can be improved in the air supply area. Thus, about 75% of the subjects are satisfied with the thermal environment. In conclusion, the distributed air supply can meet more people's requirements for thermal comfort. © 2022, Editorial Department of Journal of Hunan University. All right reserved.
引用
收藏
页码:183 / 191
页数:8
相关论文
共 18 条
  • [1] ZHANG J, ZHANG Q, CHENG H, Et al., Evolution of indoor air quality index in assessment standard for green building, Building Science, 36, 8, pp. 137-142, (2020)
  • [2] LIU J., Study on the indoor thermal environment and human thermal comfort in natural ventilation building in summer-hot and winter-cold zone, pp. 1-2, (2007)
  • [3] ZHANG H, LIN J H, CHEN J, Et al., Application of distributed air supply technology to household heat pump air conditioner, Refrigeration and Air-conditioning, 18, 2, pp. 17-21, (2018)
  • [4] LI N P, LI N, HE Y D, Et al., Human thermal responses with various local cooling methods, Journal of Hunan University(Natural Sciences), 47, 3, pp. 140-148, (2020)
  • [5] WEBSTER T, BAUMAN F, REESE J., Underfloor air distribution: thermal stratification, ASHARE Journal, 44, 5, pp. 26-28, (2002)
  • [6] LIN J H, CHEN J, HE Z J., Research on energy-saving characteristics of distributed air flow organization, Chinese Journal of Refrigeration Technology, 37, 6, pp. 67-71, (2017)
  • [7] LI N, LIAO J K, ZHENG W Q, Et al., Analysis on thermal comfort of combined system with cooling ceiling and displacement ventilation, Journal of Central South University (Science and Technology), 43, 6, pp. 2434-2440, (2012)
  • [8] ZHANG G Q, FU K N, ZHANG F, Et al., Multi-objective optimization of load ratio of CRCP-DOAS system in residential buildings, Journal of Hunan University(Natural Sciences), 47, 9, pp. 158-168, (2020)
  • [9] GONG G C, LIU J., Research on synergistic operation of mixing ventilation for air carrying energy radiant air-conditioning, Journal of Hunan University(Natural Sciences), 46, 5, pp. 148-156, (2019)
  • [10] LI N P, HE D, HE Y D, Et al., Experimental study on thermal comfort with radiant cooling workstation and desktop fan in hot-humid environment, Journal of Hunan University(Natural Sciences), 44, 11, pp. 198-204, (2017)