Recovery of bio-based volatile fatty acids from anaerobically treated winery wastewater using a closed-loop liquid-liquid hydrophobic membrane contactor system

被引:0
|
作者
Lo Coco, Riccardo [1 ]
Jelic, Aleksandra [1 ]
Jarvela, Eliisa [2 ]
Frison, Nicola [1 ]
机构
[1] Univ Verona, Dept Biotechnol, Str Grazie 15, I-37134 Verona, Italy
[2] VTT Tech Res Ctr Finland Ltd, POB 1000, Espoo 02044, Finland
关键词
Membrane contactor; Recovery; Volatile fatty acids; UASB; SLUDGE;
D O I
10.1016/j.cej.2024.156889
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This research evaluated a closed-loop hydrophobic liquid-liquid membrane contactor (MC) for the recovery of volatile fatty acids (VFAs) from the effluent of an up-flow anaerobic sludge blanket (UASB) bioreactor treating winery wastewater. Sodium bicarbonate was used as a stripping solution for its operational flexibility and compatibility with downstream bioprocesses. An electrochemical acidification cell (EAC) was tested to continuously adjust of pH of the feed solution to avoid the use of inorganic acids. VFA recovery was optimized under different flow rates and feed pH conditions using a synthetic VFA solution and validated with actual UASB effluent. Lower feed pH resulted in higher VFA recovery due to increased protonation of the acids. This effect was more pronounced when using synthetic VFA solutions compared to real UASB effluent. Specifically, the MC system recovered 16 f 5 % of acetic acid at 0.3 f 0.1 gCOD/m2h flux and 34 f 4 % of butyric acid at 0.5 f 0.1 gCOD/m2h flux at an unadjusted UASB effluent feed pH of 4.9, compared to 22 f 3 % at 0.5 f 0.1 gCOD/m2h flux and 46 f 5 % at 0.7 f 0.1 gCOD/m2h flux, respectively, at pH 2. The EAC effectively lowered the feed pH of UASB effluent to 3.9, achieving acetic acid recovery of 22 f 3 % at a mass flux of 0.2 f 0.1 gCOD/m2h, and butyric acid recovery of 45 f 1 % at a mass flux of 0.6 f 0.1 gCOD/m2h. These moderate recovery efficiencies are likely influenced by the lower pH gradient resulting from the use of sodium bicarbonate. However, the compatibility of sodium bicarbonate with bioprocesses offers the advantage that the proposed UASB-MC system can be seamlessly integrated with downstream bioprocesses to produce valuable end products for other markets, such as PHA for plastics and microbial proteins for animal feed.
引用
收藏
页数:17
相关论文
共 4 条
  • [1] Ammonia recovery from municipal wastewater using hybrid NaOH closed-loop membrane contactor and ion exchange system
    Sheikh, M.
    Lopez, J.
    Reig, M.
    Vecino, X.
    Rezakazemi, M.
    Valderrama, C. A.
    Cortina, J. L.
    CHEMICAL ENGINEERING JOURNAL, 2023, 465
  • [2] Enhancement of phenol recovery from wastewater by nanofluid utilizing liquid-liquid extraction method in a membrane-based contactor
    Yaseen, Sarmad Majeed
    Salih, Suhaib S.
    Kadhom, Mohammed
    Mohammed, Harith N.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2023, 196 : 404 - 412
  • [3] Ammonium recovery and concentration from synthetic wastewater using a poly(4-methyl-1-pentene) (PMP) liquid-liquid membrane contactor: Flux performance and mass transport characterization
    Aguilar-Moreno, M.
    Lopez, J.
    Guillen-Burrieza, E.
    Reig, M.
    Valderrama, C.
    Cortina, J. L.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 326
  • [4] Quantification of Phthalate Esters in Carbonated Soft Drinks by Hollow Fiber-Microporous Membrane Liquid-Liquid Extraction and 96-Well Plate System Using Natural Deep Eutectic Solvents Based on Fatty Acids
    Morelli, Diogo C.
    Morés, Lucas
    Carasek, Eduardo
    Journal of Separation Science, 2024, 47 (24)