A reusable neurotransmitter aptasensor for the sensitive detection of serotonin

被引:0
|
作者
Geng, Xue [1 ]
Zhang, Mengtian [1 ]
Long, Hongyan [3 ]
Hu, Ziheng [4 ]
Zhao, Biying [4 ]
Feng, Lingyan [4 ]
Du, Jiangyan [1 ,2 ]
机构
[1] College of Chemistry and Materials Science, Nanjing Normal University, Nanjing,210046, China
[2] Jiangsu Collaborative Innovation Center of Biomedical Functional Materials, Nanjing,210046, China
[3] Nanjing Hospital of Chinese Medicine Afliated to Nanjing University of Chinese Medicine, Nanjing,210012, China
[4] Materials Genome Institute, And Department of Chemistry, College of Science, Shanghai University, Shanghai,200444, China
关键词
The authors appreciate the fnancial supports from a project funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions; the National Natural Science Foundation of China (No. 21705106 ); the Program for Professor of Special Appointment (Eastern Scholar) at Shanghai Institutions of Higher Learning (No. TP2016023 ); Shanghai Natural Science Foundation (No. 18ZR1415400 ); and the Shanghai Rising-Star Program [ 20QA1403400 ];
D O I
暂无
中图分类号
学科分类号
摘要
31
引用
收藏
页码:124 / 131
相关论文
共 50 条
  • [1] A reusable neurotransmitter aptasensor for the sensitive detection of serotonin
    Geng, Xue
    Zhang, Mengtian
    Long, Hongyan
    Hu, Ziheng
    Zhao, Biying
    Feng, Lingyan
    Du, Jiangyan
    ANALYTICA CHIMICA ACTA, 2021, 1145 : 124 - 131
  • [2] Reusable, label-free electrochemical aptasensor for sensitive detection of small molecules
    Li, Bingling
    Du, Yan
    Wei, Hui
    Dong, Shaojun
    CHEMICAL COMMUNICATIONS, 2007, (36) : 3780 - 3782
  • [3] Highly sensitive, reusable electrochemical aptasensor for adenosine
    Liu, Zhongyuan
    Yuan, Ruo
    Chai, Yaqin
    Zhuo, Ying
    Hong, Chenglin
    Yang, Xia
    Su, Huilan
    Qian, Xiaoqing
    ELECTROCHIMICA ACTA, 2009, 54 (26) : 6207 - 6211
  • [4] Truncated Electrochemical Aptasensor with Enhanced Antifouling Capability for Highly Sensitive Serotonin Detection
    Hu, Ziheng
    Zhu, Ruifeng
    Figueroa-Miranda, Gabriela
    Zhou, Lei
    Feng, Lingyan
    Offenhaeusser, Andreas
    Mayer, Dirk
    BIOSENSORS-BASEL, 2023, 13 (09):
  • [5] An in situ assembly strategy for the construction of a sensitive and reusable electrochemical aptasensor
    Song, Juan
    Li, Songling
    Gao, Feng
    Wang, Qingxiang
    Lin, Zhenyu
    CHEMICAL COMMUNICATIONS, 2019, 55 (07) : 905 - 908
  • [6] Selective and sensitive colorimetric detection of the neurotransmitter serotonin based on the aggregation of bifunctionalised gold nanoparticles
    Godoy-Reyes, Tania M.
    Llopis-Lorente, Antoni
    Costero, Ana M.
    Sancenon, Felix
    Gavina, Pablo
    Martinez-Manez, Ramon
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 258 : 829 - 835
  • [7] Reusable light-emitting-diode induced chemiluminescence aptasensor for highly sensitive and selective detection of riboflavin
    Xu, Shuxia
    Zhang, Xinfeng
    Liu, Weiwei
    Sun, Yonghua
    Zhang, Heliang
    BIOSENSORS & BIOELECTRONICS, 2013, 43 : 160 - 164
  • [8] A sensitive aptasensor for the detection of Vibrio parahaemolyticus
    Wu, Wei
    Zhou, Meng
    He, Hong
    Liu, Chunzhao
    Li, Peifeng
    Wang, Man
    Liu, Ying
    Hao, Xiaodan
    Fang, Zhiyuan
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 272 : 550 - 558
  • [9] Reusable impedimetric aptasensor
    Radi, AE
    Sánchez, JLA
    Baldrich, E
    O'Sullivan, CK
    ANALYTICAL CHEMISTRY, 2005, 77 (19) : 6320 - 6323
  • [10] A reusable QCR aptasensor for the detection of Brevetoxin-2 in shellfish
    Ramalingam, Saipriya
    Hayward, Gordon L.
    Singh, Ashutosh
    TALANTA, 2021, 233