Sensorless Current Sharing Control of Three-phase Interleaved Bidirectional DC Converter

被引:0
|
作者
Li S. [1 ]
Zhao Y. [1 ]
Guo Q. [1 ]
Fu M. [1 ]
机构
[1] Energy Internet Engineering Technology Center of Chongqing City, Chongqing University of Technology, Chongqing
来源
关键词
Current sharing; Digital control; Duty cycle compensation; Equivalent resistance; Interleaved parallel converter; Sensorless;
D O I
10.13336/j.1003-6520.hve.20200302027
中图分类号
学科分类号
摘要
Aiming at the disadvantages of overabundant control loops and complex design of current detection circuit in the current sharing process of three-phase interleaved bidirectional DC-DC converters, a current-free current sharing control strategy is proposed based on traditional voltage-type control. The converter buck mode is taken as an example, and the equivalent resistance circuit model is established according to the Thevenin theorem. The relationships between the phase-to-phase current and the equivalent resistance or the effective duty cycle are analyzed. It is clear that the cause of the phase-to-phase current imbalance is the impedance mismatch. Moreover, based on one of the phases, the other two correspondingly changed duty cycles ∆D are derived and compensated. At the same time, the design method of the control loop of the current-free current sharing control system is given. The digital control technology is used to discretize the controller, and the duty cycle mismatch at the switch node is compensated to avoid the effects of the low accuracy of the current sensor, and insufficient design on the converter. The simulation and experimental results in a 25 kW prototype show that the current sharing performance is superior under various mismatches and different loads, which verifies the correctness and feasibility of the theoretical analysis. © 2021, High Voltage Engineering Editorial Department of CEPRI. All right reserved.
引用
收藏
页码:894 / 902
页数:8
相关论文
共 21 条
  • [1] CHENG P, VASIC M, GARCIA O, Et al., Minimum time control for multiphase buck converter: analysis and application, IEEE Transactions on Power Electronics, 29, 2, pp. 958-967, (2014)
  • [2] MAO H, YAO L, WANG C, Et al., Analysis of inductor current sharing in nonisolated and isolated multiphase dc-dc converters, IEEE Transactions on Industrial Electronics, 54, 6, pp. 3379-3388, (2007)
  • [3] LI Chaoyang, ZHANG Baifu, HAN Xiaoqing, Et al., Circulating current suppression method for paralleled bi-directional power converters based on adaptive virtual damping control, High Voltage Engineering, 46, 5, pp. 1550-1559, (2020)
  • [4] WANG J B, KAO D., Impedance interference investigation of the paralleled DC/DC converters system used droop current sharing control, 2015 IEEE 2nd International Future Energy Electronics Conference, pp. 1-5, (2015)
  • [5] ZHANG Junming, XIE Xiaogao, WU Xinke, Et al., Research on active current-sharing methods for DC/DC converters, Proceedings of the CSEE, 25, 19, pp. 31-36, (2005)
  • [6] QIU Dongyuan, ZHANG Bo, WEI Congying, Study of paralleled buck converters with improved automatic current-sharing technique, Transactions of China Electrotechnical Society, 20, 10, pp. 45-51, (2005)
  • [7] XIAO Wenxun, ZHANG Bo, QIU Dongyuan, Improved automatic current-sharing control based on average current mode for parallel boost converters, Proceedings of the CSEE, 27, 13, pp. 64-69, (2007)
  • [8] YOU Jiang, MENG Fanrong, ZHANG Jinnan, Design of parallel DC/DC converter current sharing controller based on loop shaping, Proceedings of the CSEE, 39, 2, pp. 585-593, (2019)
  • [9] CHAE S, SONG Y, PARK S, Et al., Digital current sharing method for parallel interleaved DC-DC converters using input ripple voltage, IEEE Transactions on Industrial Informatics, 8, 3, pp. 536-544, (2012)
  • [10] ZENG Jinhui, SUN Zhifeng, LEI Min, Et al., Sensorless current sharing control strategy of independent-input-parallel-output dual- active-bridge converters, Proceedings of the CSEE, 39, 7, pp. 2144-2155, (2019)