Frequency-domain instrument with custom ASIC for dual-slope near-infrared spectroscopy

被引:0
|
作者
Kılıç, Alper [1 ]
Blaney, Giles [2 ]
Tavakoli, Fatemeh [2 ]
Frias, Jodee [2 ]
Sassaroli, Angelo [2 ]
Fantini, Sergio [2 ]
Koomson, Valencia [1 ]
机构
[1] Department of Electrical and Computer Engineering, Tufts University, 161 College Avenue, Medford,MA,02155, United States
[2] Department of Biomedical Engineering, Tufts University, 4 Colby Street, Medford,MA,02155, United States
来源
Review of Scientific Instruments | 2024年 / 95卷 / 11期
基金
美国国家卫生研究院;
关键词
Infrared spectroscopy - Motion picture cameras - Noninvasive medical procedures - Optical variables measurement - Phase noise;
D O I
10.1063/5.0227363
中图分类号
学科分类号
摘要
Real-time and non-invasive measurements of tissue concentrations of oxyhemoglobin (HbO2) and deoxyhemoglobin (HbR) are invaluable for research and clinical use. Frequency-domain near-infrared spectroscopy (FD-NIRS) enables non-invasive measurement of these chromophore concentrations in human tissue. We present a small form factor, dual-wavelength, miniaturized FD-NIRS instrument for absolute optical measurements, built around a custom application-specific integrated circuit and a dual-slope/self-calibrating (DS/SC) probe. The modulation frequency is 55 MHz, and the heterodyning technique was used for intensity and phase readout, with an acquisition rate of 0.7 Hz. The instrument consists of a 14 × 17 cm2 printed circuit board (PCB), a Raspberry Pi 4, an STM32G491 microcontroller, and the DS/SC probe. The DS/SC approach enables this instrument to be selective to deeper tissue and conduct absolute measurements without calibration. The instrument was initially validated using a tissue-mimicking solid phantom, and upon confirming its suitability for in vivo, a vascular occlusion experiment on a human subject was conducted. For the phantom experiments, an average of 0.08° phase noise and 0.10% standard deviation over the mean for the intensities was measured at a source-detector distance of 35 mm. The absorption and reduced scattering coefficients had average precisions (variation of measurement over time) of 0.5% and 0.9%, respectively, on a window of ten frames. Results from the in vivo experiment yielded the expected increase in HbO2 and HbR concentration for all measurement types tested, namely SC, DS intensity, and DS phase. © 2024 Author(s).
引用
收藏
相关论文
共 50 条
  • [1] Dual-slope imaging of cerebral hemodynamics with frequency-domain near-infrared spectroscopy
    Blaney, Giles
    Fernandez, Cristianne
    Sassaroli, Angelo
    Fantini, Sergio
    NEUROPHOTONICS, 2023, 10 (01)
  • [2] Dual-slope imaging in highly scattering media with frequency-domain near-infrared spectroscopy
    Blaney, Giles
    Sassaroli, Angelo
    Fantini, Sergio
    OPTICS LETTERS, 2020, 45 (16) : 4464 - 4467
  • [3] Single-distance and dual-slope frequency-domain near-infrared spectroscopy to assess skeletal muscle hemodynamics
    Fernandez, Cristianne
    Blaney, Giles
    Frias, Jodee
    Tavakoli, Fatemeh
    Sassaroli, Angelo
    Fantini, Sergio
    JOURNAL OF BIOMEDICAL OPTICS, 2023, 28 (12)
  • [4] Frequency-Domain Techniques for Cerebral and Functional Near-Infrared Spectroscopy
    Fantini, Sergio
    Sassaroli, Angelo
    FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [5] Functional mapping of the human brain with near-infrared spectroscopy in the frequency-domain
    Sassaroli, A
    Tong, YJ
    Fabbri, F
    Frederick, B
    Renshaw, P
    Fantini, S
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS XIV, 2004, 5312 : 371 - 377
  • [6] Assessment of Infant Brain Development With Frequency-Domain Near-Infrared Spectroscopy
    Maria Angela Franceschini
    Sonal Thaker
    George Themelis
    Kalpathy K Krishnamoorthy
    Heather Bortfeld
    Solomon G Diamond
    David A Boas
    Kara Arvin
    P Ellen Grant
    Pediatric Research, 2007, 61 : 546 - 551
  • [7] Effects of improper source coupling in frequency-domain near-infrared spectroscopy
    Noponen, T. E. J.
    Kotilahti, K.
    Nissila, I.
    Kajava, T.
    Merilainen, P. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10): : 2941 - 2960
  • [8] Functional cerebral activation detected by frequency-domain near-infrared spectroscopy
    Toronov, V
    Webb, AG
    Choi, JH
    Wolf, M
    Safonova, LP
    Wolf, U
    Gratton, E
    SARATOV FALL MEETING 2001: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE III, 2001, 4707 : 92 - 96
  • [9] Assessment of infant brain development with frequency-domain near-infrared spectroscopy
    Franceschini, Maria Angela
    Thaker, Sonal
    Themelis, George
    Krishnamoorthy, Kalpathy K.
    Bortfeld, Heather
    Diamond, Solomon G.
    Boas, David A.
    Arvin, Kara
    Grant, P. Ellen
    PEDIATRIC RESEARCH, 2007, 61 (05) : 546 - 551
  • [10] Optimization of the frequency-domain instrument for the near-infrared spectro-imaging of the human brain
    Toronov, V
    DíAmico, E
    Hueber, D
    Gratton, E
    Webb, A
    Barbieri, B
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS XIV, 2004, 5312 : 378 - 383