Optimal design method for structures with viscous dampers in base isolation layer

被引:0
|
作者
Li B. [1 ]
Zhang Y. [1 ]
Yan G. [1 ]
Gu H. [1 ]
机构
[1] School of Civil Engineering, Chang'an University, Xi'an
关键词
Base-isolated structure; Energy balance equation; Optimal design; Prediction of earthquake response; Viscous damper;
D O I
10.11918/202108032
中图分类号
学科分类号
摘要
In order to effectively design the viscous dampers in the isolation layer of base-isolated structures, an optimal design method was proposed to determine the damper parameters with the design emphasis of displacement and shear force of isolation layer. The seismic energy balance equation of base-isolated structures with viscous dampers was established. A simple method was given for predicting the maximum displacement and total shear coefficient of isolation layer using input energy at the end of earthquake. The accuracy of the prediction method was verified by dynamic time history analysis. Results show that the prediction accuracy increased with the increase in the additional damping ratio. The response reduction effect of the isolation layer under the optimal shear design was analyzed. Based on the design principle of solving the minimum value of the combination function of response ratios, an objective function for the optimal design was constructed by using the linear combination of total shear response ratio and displacement response ratio. The responses of the isolation layer under four typical design objectives were analyzed, and the optimal design process of the isolation layer with viscous dampers was given. Finally, a six-story steel frame base-isolated structure with viscous dampers was designed and its seismic performance was verified. The design example proved that the optimal design method is of feasibility and convenience. The prediction method can be used as a response checking method with good accuracy and safety. The viscous dampers design method which can optimize the displacement and shear response of isolation layer is efficient, and the design process is suitable for manual calculation. Copyright ©2022 Journal of Harbin Institute of Technology.All rights reserved.
引用
收藏
页码:101 / 110
页数:9
相关论文
共 17 条
  • [1] Recommendation for the design of base isolated buildings, (2006)
  • [2] AKIYAMA H., Earthquake-resistant design method for buildings based on energy balance, (2010)
  • [3] PROVIDAKIS C P., Effect of LRB isolators and supplemented viscous dampers on seismic isolated buildings under near fault excitations, Engineering Structures, 30, 5, (2008)
  • [4] PROVIDAKIS C P., Effect of supplemental damping on LRB and FPS seismic isolators under near-fault ground motions, Soil Dynamics and Earthquake Engineering, 29, 1, (2009)
  • [5] HIGASHINO S, KITAMURA H., Energy-balance based seismic response prediction methods for seismic isolated buildings with rubber bearings and viscous dampers, Journal of Structural and Construction Engineering, 70, 588, (2005)
  • [6] WANG Wei, PEI Xingzhu, WANG Xingxing, Earthquake response prediction of a base-isolated structure with dampers based on energy concept, World Earthquake Engineering, 27, 4, (2011)
  • [7] KITAMURA H., Seismic response analysis methods for performance based design, (2004)
  • [8] CHEN Ruisheng, WU Jinbiao, LIU Yanhui, Et al., Optimization research for base-isolated structures with fluid viscous dampers, Journal of Vibration and Shock, 39, 11, (2020)
  • [9] WANG Mingxu, CHEN Guoping, Optimization on placement and parameters of damping design using energy criterion, Journal of Vibration, Measurement & Diagnosis, 31, 6, (2011)
  • [10] LI Gang, ZHAI Zijie, YU Dinghao, An efficient optimal design method for dampers, Journal of Architecture and Civil Engineering, 37, 5, (2020)