Development and validation study of compact biophotonic platform for detection of serum biomarkers

被引:1
|
作者
Tortajada-Genaro, Luis Antonio [1 ,2 ,3 ]
Quintero-Campos, Pedro [1 ]
Juarez, Maria Jose [1 ]
Ibanez-Echevarria, Ethel [4 ]
Chiriac, Anca Mirela [5 ]
Fernandez, Estrella [1 ]
Morais, Sergi [1 ,2 ,3 ]
Maquieira, Angel [1 ,2 ,3 ]
机构
[1] Univ Valencia, Univ Politecn Valencia, Inst Interuniv Invest Reconocimiento Mol & Desarro, Camino Vera S-N, Valencia 46022, Spain
[2] Univ Politecn Valencia, Dept Quim, Valencia, Spain
[3] UPV La Fe, Unidad Mixta, Nanomed & Sensors, Valencia, Spain
[4] Hosp Univ & Politen La Fe, Serv Alergol, Avinguda Fernando Abril Martorell 106, Valencia 46026, Spain
[5] Univ Hosp Montpellier, Hop Arnaud Villeneuve, Dept Pulmonol, Div Allergy, Montpellier, France
基金
欧盟地平线“2020”;
关键词
Bio-photonics; Compact disc technology; Serum biomarkers; Centrifugal microfluidics; Micro-immunoassay; Drug allergy; DIAGNOSTICS RECENT DEVELOPMENTS; AMPLIFICATION; BIOSENSORS; DEVICES; MICROARRAYS; GENERATION; DISCS; TIME;
D O I
10.1016/j.talanta.2024.126511
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The application of advances in personalized medicine requires the support of in vitro diagnostic techniques aimed at the accurate, fast, sensitive, and precise determination of selected biomarkers. Herein, a novel optical centrifugal microfluidic device is developed for clinical analysis and point-of-care diagnostics. Based on compact disc technology, the integrated biophotonic system enables multiple immunoassays in miniaturized mode. The disposable microfluidic discs are made in cyclic olefin copolymer (COP), containing arrays of immobilized probes. In the developed approach, up to six patient samples can each be tested simultaneously. A portable instrument (<2 kg) controls the assay and the high-sensitive reproducible optical detection in transmission mode. Also, the instrument incorporates specific functionalities for personalized telemedicine. The device (analytical method, disc platform, reader, and software) has been validated to diagnose IgE-mediated drug allergies, such as amoxicillin and penicillin G. The total and specific IgE to beta-lactam antibiotics were determined in human serum from patients (25 mu L). The excellent analytical performances (detection limit 0.24 ng/mL, standard deviation 7-20 %) demonstrated that the developed system could have the potential for a broader impact beyond the allergy field, as it applies to other IVD tests.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Validation Processes of Protein Biomarkers in Serum-A Cross Platform Comparison
    Koehler, Katja
    Seitz, Harald
    SENSORS, 2012, 12 (09): : 12710 - 12728
  • [2] Development and validation of 50 serum cancer multiplexed biomarkers
    Stephen, Laurie L.
    Ballard, Karri L.
    McDade, Ralph L.
    Mapes, James P.
    CANCER RESEARCH, 2010, 70
  • [3] A Response Assessment Platform for Development and Validation of Imaging Biomarkers in Oncology
    Yang, Hao
    Schwartz, Lawrence H.
    Zhao, Binsheng
    TOMOGRAPHY, 2016, 2 (04) : 406 - 410
  • [4] An Ultrasensitive Platform for the Detection of Protein Biomarkers in Spiked Human Serum
    Vance, Stephen
    Sandros, Marinella
    PROTEIN SCIENCE, 2014, 23 : 78 - 78
  • [5] Validation of Candidate Serum Ovarian Cancer Biomarkers for Early Detection
    Su, Feng
    Lang, Jennifer
    Kumar, Ashutosh
    Ng, Carey
    Hsieh, Brian
    Suchard, Marc A.
    Reddy, Srinivasa T.
    Farias-Eisner, Robin
    BIOMARKER INSIGHTS, 2007, 2 : 369 - 375
  • [6] A compact gas chromatography platform for detection of multicomponent volatile organic compounds biomarkers
    Wu, Xinyu
    Wang, Dazuo
    Shi, Lujia
    Wang, Hairong
    Wang, Jiuhong
    Sun, Jianhai
    Li, Changqing
    Tian, Xin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (06):
  • [7] Development of New Serum Biomarkers for Early Lymphedema Detection
    Herrada, Andres A.
    Mejias, Camila
    Lazo-Amador, Rodrigo
    Olate-Briones, Alexandra
    Lara, Danitza
    Escobedo, Noelia
    LYMPHATIC RESEARCH AND BIOLOGY, 2020, 18 (02) : 136 - 145
  • [8] Validation of serum biomarkers for detection of early-stage ovarian cancer
    Nosov, Vladimir
    Su, Feng
    Amneus, Malaika
    Birrer, Michael
    Robins, Terry
    Kotlerman, Jenny
    Reddy, Srinivasa
    Farias-Eisner, Robin
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2009, 200 (06) : 639.e1 - 639.e5
  • [9] Molecular epidemiological study on smoking-associate lung cancer: Detection and validation of protein biomarkers in serum
    Wang, Wenjing
    Lu, Wei
    Xiang, Cuiqin
    CANCER RESEARCH, 2006, 66 (08)
  • [10] mCerebrum: A Mobile Sensing Software Platform for Development and Validation of Digital Biomarkers and Interventions
    Hossain, Syed Monowar
    Hnat, Timothy
    Saleheen, Nazir
    Nasrin, Nusrat Jahan
    Noor, Joseph
    Ho, Bo-Jhang
    Condie, Tyson
    Srivastava, Mani
    Kumar, Santosh
    PROCEEDINGS OF THE 15TH ACM CONFERENCE ON EMBEDDED NETWORKED SENSOR SYSTEMS (SENSYS'17), 2017,