PROPOSAL OF DEFORMATION HISTORY INTEGRAL TYPE HYSTERESIS MODEL CONSIDERING PERFORMANCE CHANGE OF HIGH-DAMPING RUBBER BEARINGS AND VERIFICATION USING SUBSTRUCTURE REAL-TIME ONLINE TESTING SYSTEM FOR SEISMICALLY ISOLATED STRUCTURE

被引:0
|
作者
Mori T. [1 ]
Takeuchi S. [1 ]
Maruyama K. [1 ]
Kato K. [1 ]
Murota N. [1 ]
Suzuki S. [1 ]
机构
[1] Bridgestone Corporation, Seismic Isolation and Vibration Control Products Development Dept
来源
Journal of Structural and Construction Engineering | 2022年 / 87卷 / 799期
关键词
High-damping rubber bearing; Hysteresis model; Performance change; Seismic isolation; Substructure real-time online test; Time history response analysis;
D O I
10.3130/aijs.87.890
中图分类号
学科分类号
摘要
Improved deformation history integral type hysteresis model (DHI model) is proposed. Original DHI model was elasto-plastic model and developed mainly for high-damping rubber bearings. While the model can represent the complex behavior of high-damping rubber bearings, there is an issue that the model cannot consider the performance change. Thus, the model was improved by defining the material parameters as a function of performance change ratio. In order to confirm the accuracy of the proposed model, time history analysis was carried out and compared the result of analysis with that of substructure real-time online testing system. © 2022 Architectural Institute of Japan. All rights reserved.
引用
收藏
页码:890 / 901
页数:11
相关论文
共 7 条
  • [1] Proposal of deformation history integral-type hysteresis model considering performance change of high-damping rubber bearings and verification using substructure real-time online testing system for seismically isolated structure
    Mori, Takahiro
    Takeuchi, Sadamitsu
    Maruyama, Kenji
    Kato, Koji
    Murota, Nobuo
    Suzuki, Shigenobu
    JAPAN ARCHITECTURAL REVIEW, 2023, 6 (01):
  • [2] Proposal of deformation history integral-type hysteresis model considering performance change of high-damping rubber bearings and verification using substructure real-time online testing system for seismically isolated structure
    Mori, Takahiro
    Takeuchi, Sadamitsu
    Maruyama, Kenji
    Kato, Koji
    Murota, Nobuo
    Suzuki, Shigenobu
    Japan Architectural Review, 6 (01):
  • [3] Development of an Improved Deformation History Integral Type Hysteresis Model for High-Damping Rubber Bearings
    Mori, Takahiro
    Takeuchi, Sadamitsu
    Murota, Nobuo
    SEISMIC ISOLATION, ENERGY DISSIPATION AND ACTIVE VIBRATION CONTROL OF STRUCTURES, 17WCSI 2022, 2023, 309 : 198 - 206
  • [4] Seismic analysis of a reinforced concrete building isolated by high damping rubber bearings using deformation history integral type model
    Hu, Xiaorong
    Zhou, Zhiguang
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (18):
  • [5] Investigation of seismic performance of high damping rubber bearings for isolated bridges using real-time substructure hybrid loading test method
    Yuan, Yong
    Iemura, Hirokazu
    Igarashi, Akira
    Aoki, Tetsuhiko
    Yamamoto, Yoshihisa
    Doboku Gakkai Ronbunshuu A, 2007, 63 (01) : 265 - 276
  • [6] DYNAMIC PERFORMANCE STUDY ON THE SUPER HIGH DAMPING RUBBER ISOLATION BEARINGS DEPEND ON THE REAL-TIME SUBSTRUCTURE HYBRID LOADING SYSTEM
    Yi, Liu
    Yuan, Yong
    Ai, Demi
    PROCEEDINGS OF THE TWELFTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS I AND II, 2012, : 745 - 751
  • [7] DEVELOPMENT OF SUBSTRUCTURE REAL-TIME ONLINE TESTING SYSTEM FOR SEISMICALLY ISOLATED BUILDING WITH A SMALL RESPONSE DELAY USING EXISTING EXPERIMENTAL EQUIPMENT
    Takeuchi S.
    Mori T.
    Sato D.
    Inubushi T.
    Ougiya N.
    Kanda M.