Analysis of Thermal Comfort of the Building Envelope Using an Earth-Air Heat Exchanger

被引:0
|
作者
MICHELE, Soares Netto [1 ]
da RUTHDS, Silva Brum [2 ]
da JOSEANEDS, Silva Porto [3 ]
CÉSARO, Avellaneda [1 ]
机构
[1] Centro de Desenvolvimento Tecnológico, Universidade Federal de Pelotas, Rua Gomes Carneiro, 1, Centro, RS, Pelotas,96010-610, Brazil
[2] Centro de Engenharias, Universidade Federal de Pelotas, Rua Benjamin Constant, 989, Porto, RS, Pelotas,96010-020, Brazil
[3] Instituto de Física e Matemática, Universidade Federal de Pelotas, Campus Universitário s/no, RS, Capão do Leão,96160-000, Brazil
关键词
The constructive elements of a building influence the demand for electrical energy; and optimal decisions can be assessed with the support of software that measures this building's demand more accurately. The objective of this research is to assess the thermal behavior of a residentiald welling located in bioclimatic zone 2 in the southern region of Brazil; seeking energy sources that contribute to improving thermal comfort. The study utilizes parameters that reduce the thermal demand for cooling and heating by installing an earth-air heat exchanger (EAHE) in the prolonged occupancy enviroments (POEs) within the building. The results obtained in the Energy Plus soft ware show that the adaptive comfort of the model with the Earth-Air Heat Exchanger (EAHE); compared to without it; reduces cold discomfort by 5.4% and increases thermal comfort in the building by 5.2%.Analyzing the annual temperatures of the spaces with the EAHE; it is observed that the outlet temperature of the EAHE duct remains at an average of 23.6°C and 23.8°C for the living room and bedrooms; respectively. From an energy perspective; the electrical energy consumption of the building was reduced by 29.8% when using the EAHE. © 2024 Trans Tech Publications Ltd; All Rights Reserved;
D O I
10.4028/p-5o95Fd
中图分类号
学科分类号
摘要
引用
收藏
页码:91 / 100
相关论文
共 50 条
  • [1] Thermal modeling for greenhouse heating by using thermal curtain and an earth-air heat exchanger
    Shukla, A
    Tiwari, GN
    Sodha, MS
    BUILDING AND ENVIRONMENT, 2006, 41 (07) : 843 - 850
  • [2] Thermal Performance of Earth-Air Heat Exchanger Using an Experimental Test Rig
    Ahmad, Saif Nawaz
    Prakash, Om
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2023, 48 (09) : 11665 - 11678
  • [3] Experimental and numerical analysis of an earth-air heat exchanger
    Vaz, Joaquim
    Sattler, Miguel A.
    dos Santos, Elizaldo D.
    Isoldi, Liercio A.
    ENERGY AND BUILDINGS, 2011, 43 (09) : 2476 - 2482
  • [4] A Numerical Investigation of Thermal Performance of Earth-Air Heat Exchanger
    Tasdelen, F.
    Dagtekin, I.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (02) : 1151 - 1163
  • [5] Numerical and Experimental Analysis of an Earth-Air Heat Exchanger
    Diedrich, Carlos Henrique
    dos Santos, Gerson Henrique
    Carraro, Gustavo Chaves
    Dimbarre, Victor Vaurek
    Alves, Thiago Antonini
    ATMOSPHERE, 2023, 14 (07)
  • [6] Performance Analysis of PCM Ceiling Coupling with Earth-Air Heat Exchanger for Building Cooling
    Lu, Shilei
    Liang, Bin
    Li, Xinhua
    Kong, Xiangfei
    Jia, Wei
    Wang, Lu
    MATERIALS, 2020, 13 (13) : 1 - 17
  • [7] Investigation on performance of building-integrated earth-air heat exchanger
    Hsu, Chien-Yeh
    Chiang, Yuan-Ching
    Chien, Zi-Jie
    Chen, Sih-Li
    ENERGY AND BUILDINGS, 2018, 169 : 444 - 452
  • [8] Techno-economic analysis of an earth-air heat exchanger for cooling and heating of a building
    Shukla, Ashish
    Tiwari, G. N.
    Sodha, M. S.
    Energy Conversion and Resources - 2005, 2005, : 409 - 415
  • [9] Parametric and experimental study on thermal performance of an earth-air heat exchanger
    Shukla, Ashish
    Tiwari, G. N.
    Sodha, M. S.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2006, 30 (06) : 365 - 379
  • [10] Design of earth-air heat exchanger system
    Bisoniya, Trilok Singh
    GEOTHERMAL ENERGY, 2015, 3