Electron cyclotron emission quasi-optical transmission system on the HL-3 tokamak

被引:0
|
作者
Yu, X. [1 ]
Shi, Z.B. [1 ]
Yang, Z.C. [1 ]
Jiang, M. [1 ]
Chen, W. [1 ]
Yu, G.Y. [2 ]
Zhu, Y.L. [2 ]
Deng, W.C. [1 ]
Zhou, Y. [1 ]
Shen, Y.Q. [1 ]
Wen, J. [1 ]
Shi, P.W. [1 ]
Han, K.X. [1 ]
机构
[1] Southwestern Institute of Physics, Chengdu,610041, China
[2] Depatment of Electrical and Computer Engineering, University of California, Davis,CA,95616, United States
来源
Review of Scientific Instruments | 2024年 / 95卷 / 11期
关键词
Tokamak devices;
D O I
10.1063/5.0231756
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Quasi-optical design for the cross-polarization scattering diagnostic on the HL-3 tokamak
    Zhou, Y.
    Tong, R. H.
    Zhong, W. L.
    Tan, Y.
    Jiang, M.
    Shi, Z. B.
    Yang, Z. C.
    Shen, Y. Q.
    Wen, J.
    Liang, A. S.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (05):
  • [2] Quasi-optical electron cyclotron emission imaging diagnostic advancements on the J-TEXT tokamak
    Xie, X. L.
    Zhou, J.
    Zhu, Y.
    Pan, X. M.
    Zhou, H.
    Yu, G.
    Luhmann, N. C.
    Zhuang, G.
    Yang, Z. J.
    FUSION ENGINEERING AND DESIGN, 2020, 155
  • [3] Influence of ion cyclotron range of frequencies heating on neutron emission rate in HL-3 tokamak
    Yang G.
    Hao G.
    Lu L.
    Dong G.
    Hao B.
    Wang S.
    He Jishu/Nuclear Techniques, 2024, 47 (05):
  • [4] Design of quasi-optical ECRH transmission system of HL-1 tokamak and high power measurement
    Xue, Siwen
    Liu, Guangyu
    Liu, Yong
    Xu, Yaochong
    Li, Xiaodong
    Hejubian Yu Dengliziti Wuli/Nuclear Fusion and Plasma Physics, 1994, 14 (02): : 28 - 36
  • [5] Optimization of the optical system for electron cyclotron emission imaging diagnostics on the HL-2A tokamak
    Jiang, Min
    Shi, Zhongbing
    Zhu, Yilun
    PLASMA SCIENCE & TECHNOLOGY, 2017, 19 (08)
  • [6] Optimization of the optical system for electron cyclotron emission imaging diagnostics on the HL-2A tokamak
    蒋敏
    石中兵
    朱逸伦
    Plasma Science and Technology, 2017, 19 (08) : 29 - 33
  • [7] Optimization of the optical system for electron cyclotron emission imaging diagnostics on the HL-2A tokamak
    蒋敏
    石中兵
    朱逸伦
    Plasma Science and Technology, 2017, (08) : 29 - 33
  • [8] A QUASI-OPTICAL ELECTRON-CYCLOTRON MASER
    VOMVORIDIS, JL
    SPRANGLE, P
    MANHEIMER, WM
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (08): : 948 - 948
  • [9] Development of electron cyclotron emission imaging system on the HL-2A tokamak
    Jiang, M.
    Shi, Z. B.
    Che, S.
    Domier, C. W.
    Luhmann, N. C., Jr.
    Hu, X.
    Spear, A.
    Liu, Z. T.
    Ding, X. T.
    Li, J.
    Zhong, W. L.
    Chen, W.
    Che, Y. L.
    Fu, B. Z.
    Cui, Z. Y.
    Sun, P.
    Liu, Y.
    Yang, Q. W.
    Duan, X. R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (11):
  • [10] Design and development of ECRH launcher system on HL-3 tokamak
    Zheng W.
    Ye J.
    Chen G.
    Huang M.
    He Jishu/Nuclear Techniques, 2024, 47 (05):