Misoperation of high impedance differential protection for main transformer

被引:0
|
作者
Yuan, Cheng [1 ,2 ]
Tai, Nengling [1 ]
机构
[1] Department of Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, China
[2] Shanghai Electric High Voltage Industry, Shanghai 200063, China
关键词
Electric currents - Transformer protection - Electric power system protection;
D O I
暂无
中图分类号
学科分类号
摘要
The misoperation of the high impedance differential protection for main transformer No.3 in a substation is analyzed based on its principle and main features. Research result shows that, under the nearby large current fault, the differential current induced by the big difference of U-I characteristics between the current transformer of common winding and that of 500 kV or 220 kV presents big value, which will cause the protection misoperation. The counter-measure is to increase the protective settings by adjusting the variable resistors in RADHA differential circuit, which avoids the misoperation caused by the unbalanced currents and voltages generated in RADHA by the through currents during external fault. Field operation shows its effectiveness.
引用
收藏
页码:121 / 123
相关论文
共 50 条
  • [1] Analysis of traction transformer differential protection misoperation and its solution
    Lin, Guo-Song
    Li, Qun-Zhan
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2007, 27 (05): : 122 - 125
  • [2] Study on the Unusual Misoperation of Differential Protection During Transformer Energization and its Countermeasure
    Qi, Xuanwei
    Yin, Xianggen
    Zhang, Zhe
    Chen, Deshu
    Wang, Yi
    Cai, Fei
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (05) : 1998 - 2007
  • [3] High-Impedance Bus Differential Misoperation Due to Circuit Breaker Restrikes
    Koellner, Kristian
    Reynisson, Oskar
    Costello, David
    2014 67TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2014, : 357 - 366
  • [4] High Impedance Differential protection system versus Low Impedance Differential protection system
    Jankovic, Ilija
    2015 68TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2015, : 898 - 942
  • [5] Using Iop characteristics to troubleshoot transformer differential relay misoperation
    Thompson, M
    Closson, JR
    NETA: TECHNICAL CONFERENCE PAPERS, 2001, : 3 - 21
  • [6] Analysis and disposal of a main transformer's differential protection fault
    Hao, Jian-Hong
    Wang, Guang-Zhong
    Ji, Xi-Jun
    Song, Yong-Jian
    Zhou, Yong-Chun
    Peng, Xiao-Bin
    Wang, Pu-Wei
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (02): : 126 - 127
  • [7] A simple analysis of the misoperation reasons of line fiber differential protection when a no-load transformer is put into operation
    Zhang, Xiao-Lei
    Wu, Kun
    Wen, Yu-Rui
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (23): : 145 - 148
  • [8] Study of high-impedance transformer backup protection
    Huang, Shu
    Deng, Mao-Jun
    Zhang, Peng-Yuan
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (22): : 166 - 169
  • [9] Impact of transformer primary wiring on microcomputer-based main transformer differential protection
    Chen, Xin
    Liu, Jiang-Tao
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (20): : 125 - 129
  • [10] Analysis and countermeasure for misoperation of longitudinal differential protection with unclear reason
    Wang, Weijian
    Li, Fuying
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 1999, 23 (18): : 17 - 19