Microchannel plate gated X-ray nanosecond framing camera

被引:0
|
作者
Niu, Lihong [1 ]
Liu, Jinyuan [1 ]
Peng, Wenda [1 ]
Niu, Hanben [1 ]
Yang, Qinlao [1 ]
Liao, Hua [1 ]
Zhou, Junlan [1 ]
Zhang, Jinsong [1 ]
机构
[1] Institute of Optoelectronics, Shenzhen University, Shenzhen 518060, China
来源
Guangxue Xuebao/Acta Optica Sinica | 2008年 / 28卷 / 07期
关键词
Light emission - Phosphors - Pinch effect - CCD cameras - Microchannels - Pinhole cameras - Image storage tubes;
D O I
10.3788/AOS20082807.1274
中图分类号
学科分类号
摘要
A novel microchannel plate (MCP) gated X-ray nanosecond framing camera is developed. The camera system consists of a proximity-focused framing image-converted tube with traveling-wave gated micro-stripe optoelectric cathode, an electronic control unit, a mechanical system for pinholes mounting, adjusting and a high vacuum system. The electronic control unit provides all the power supply of the camera system including voltage to phosphor screen, gating pulses to MCP, bias and static checking voltage of MCP. The images are recorded with a scientific CCD camera coupled to the fiber optic phosphor screen. The photocathode of image-converted tube consists of Au of 50 nm thickness. Eight framing images can be abstained. The energy spectrum response of the camera ranges from 0.1 keV to 10 keV. The exposure time of the camera can be changed is 1 ns, 2 ns and 5 ns in three scales and time interval between frames from 2 ns, 5 ns and 10 ns in three scales. The dynamic spatial resolution is better than 18 lp/mm. The triggering jitter is down to 100 ps with exposure time shifting less than 5%. The fiber remote transmission and control are incorporated in the nanosecond framing camera system. The achieval experimental results on the static, dynamic characteristics and Z-pinch application show that the camera can run in a strong electromagnetic environment. In this case, the camera has little geometric distortion and wide dynamic range and provides good control and high capturing rate. Such a camera system can be utilized in the investigation of Z-pinch for recording X-ray.
引用
收藏
页码:1274 / 1278
相关论文
共 50 条
  • [1] Three-strip microchannel plate gated x-ray framing camera
    Cai, Houzhi
    Fu, Wenyong
    Wang, Dong
    Lei, Yunfei
    Liu, Jinyuan
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 285 : 355 - 361
  • [2] Uniform design method of the exposure time of X-ray picoseconds framing camera with gated microchannel plate
    Yang, Wen-Zheng
    Hou, Xun
    Bai, Yong-Lin
    Bai, Xiao-Hong
    Tian, Jin-Shou
    Liu, Bai-Yu
    Zhao, Jun-Ping
    Qin, Jun-Jun
    Ouyang, Xian
    Guangzi Xuebao/Acta Photonica Sinica, 2008, 37 (03): : 439 - 443
  • [3] An improvement method of the simultaneity of image on ultra high-speed X-ray framing camera with the gated microchannel plate detector
    Ito, Y
    Katoh, Y
    Kagata, M
    Nisiyama, S
    Tomioka, S
    Enoto, T
    25TH INTERNATIONAL CONGRESS ON HIGH-SPEED PHOTOGRAPHY AND PHOTONICS, 2003, 4948 : 739 - 744
  • [4] Spatially resolved research of picosecond X-ray multiframes camera with gated microchannel plate
    State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China
    不详
    不详
    Guangzi Xuebao, 2007, 12 (2209-2214):
  • [5] Large-format microchannel plate gated framing camera
    Cai, Houzhi
    Liu, Jinyuan
    Peng, Xiang
    Li, Wenfei
    Deng, Qijun
    Zhang, Taohua
    Zhou, Junlan
    Peng, Wenda
    Niu, Hanben
    Long, Jinghua
    Yang, Guohong
    Liu, Shenye
    Ding, Yongkun
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 677 : 14 - 17
  • [6] NANOSECOND FRAME X-RAY IMAGE CONVERTER WITH A MICROCHANNEL PLATE
    ARANCHUK, LE
    AIVAZOV, IK
    BOGOLYUBSKII, SL
    VOLKOV, GS
    ZAIDEL, IN
    PEREVODCHIKOVA, GI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1983, 26 (01) : 190 - 193
  • [7] A large-format gated x-ray framing camera
    Oertel, JA
    Archuleta, T
    Bakeman, M
    Sanchez, P
    Sandoval, G
    Schrank, L
    Walsh, P
    Pederson, N
    FOURTH-GENERATION X-RAY SOURCES AND ULTRAFAST X-RAY DETECTORS, 2004, 5194 : 214 - 222
  • [8] A sealed X-ray microchannel plate imager with CsI photocathode to improve quantitative precision of framing camera
    Yang, Yang
    Zhu, Bingli
    Gou, Yongsheng
    Chen, Zhen
    Bai, Xiaohong
    Qin, Junjun
    Bai, Yonglin
    Liu, Baiyu
    Cao, Weiwei
    Wang, Bo
    Xu, Peng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1005
  • [9] NANOSECOND X-RAY FRAMING CAMERA FOR DENSE-PLASMA SOURCES
    HELAVA, H
    EICHENBERGER, C
    GILMAN, C
    SCHNEIDER, R
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 996 - 996
  • [10] Note: Non-gain microchannel plate gated framing camera
    Cai, Houzhi
    Liu, Jinyuan
    Peng, Xiang
    Niu, Lihong
    Peng, Wenda
    Niu, Hanben
    Long, Jinghua
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (05):