An active detection scheme for permanent fault identification before phase-to-phase reclosing in a distribution network

被引:0
|
作者
Shao W. [1 ]
Liu Y. [1 ]
Guan X. [1 ]
Jiao Z. [1 ]
机构
[1] School of Electronics and Information, Xi'an Polytechnic University, Xi'an
关键词
Adaptive reclosure; Additional capacitance; Distribution network; Permanent fault; Phase-to-phase fault;
D O I
10.19783/j.cnki.pspc.201139
中图分类号
O441.1 [电学]; TM12 [];
学科分类号
摘要
Traditional auto-reclosing may reclose to the permanent fault after a phase-to-phase fault occurs in the distribution line. Thus an active detection scheme for identifying the permanent fault of a distribution network before phase-to-phase reclosing, with additional capacitance, is proposed. The pre-charged additional capacitor is switched to the phase to phase circuit after tripping for several times, and the fault circuit state is identified using the discharge current attenuation characteristics of three phase-to-phase circuits. When the discharge current attenuation characteristics of any circuit are significantly different from those of other circuits, there is a fault in the phase-to-phase circuit. If the discharge current attenuation characteristics of the circuit are highly consistent in the discrimination period, the phase-to-phase fault is considered as a permanent fault. According to the difference of discharge current attenuation characteristics between phase-to-phase circuits, a permanent fault identification criterion and its implementation scheme are established. The simulation results based on PSCAD show that the proposed scheme can accurately identify a permanent phase-to-phase fault in different fault locations and with different transition resistances. This is helpful in avoiding the blindness of reclosing action of a phase-to-phase fault in a distribution network. © 2021 Power System Protection and Control Press.
引用
收藏
页码:96 / 103
页数:7
相关论文
共 23 条
  • [1] LIU Jian, ZHANG Zhihua, WU Shuilan, Et al., Fault processing with coordination of primary equipments and secondary devices, Power System Protection and Control, 47, 20, pp. 1-6, (2019)
  • [2] ZHU Ke, LI Deqiang, TUO Jianjun, Et al., Application of active disturbance technology in detecting interphase fault of de-energized distribution lines, Electric Power Automation Equipment, 37, 1, pp. 191-196, (2017)
  • [3] SHEN Jun, SHU Zhihuai, CHEN Jun, Et al., Application of adaptive auto-reclosure in power system, Automation of Electric Power Systems, 42, 6, pp. 152-156, (2018)
  • [4] LIU Jian, ZHANG Zhihua, ZHANG Xiaoqing, Investigation on fault processing for electric power distribution networks, Power System Protection and Control, 45, 20, pp. 1-6, (2017)
  • [5] ZHANG Wei, SONG Guobing, DOU Minna, Et al., A quick fault location and isolation method in distribution network based on adaptive reclosure, Power System Protection and Control, 47, 18, pp. 60-67, (2019)
  • [6] RADOJEVIC Z M, SHIN J R., New one terminal digital algorithm for adaptive reclosing and fault distance calculation on transmission lines, IEEE Transactions on Power Delivery, 21, 3, pp. 1231-1237, (2006)
  • [7] LUO Xunhua, HUANG Chun, JIANG Yaqun, Et al., Adaptive single-phase reclosure scheme for transmission lines with shunt reactors based on current inner product, IET Generation, Transmission & Distribution, 11, 7, pp. 1770-1776, (2017)
  • [8] RADOJEVIC Z M, SHIN J R., New digital algorithm for adaptive reclosing based on the calculation of the faulted phase voltage total harmonic distortion factor, IEEE Transactions on Power Delivery, 22, 1, pp. 37-41, (2007)
  • [9] SHAO Wenquan, LIU Pengyue, WANG Bin, Et al., Single-phase adaptive reclosure fault identification for transmission lines with shunt reactors based on equivalent impedance phase property, Power System Technology, 44, 5, pp. 1796-1805, (2020)
  • [10] HUANG Xinghua, SONG Guobing, WANG Ting, Et al., Three-phase adaptive reclosure for transmission lines with shunt reactors using mode current oscillation frequencies, The Journal of Engineering, 15, pp. 1012-1017, (2018)