Corrosion Resistance and Hemocompatibility of Passivated 316L Stainless Steel

被引:0
|
作者
Wang J. [1 ]
Liu Y. [1 ,2 ]
机构
[1] School of Mechanical and Electrical Engineering, Nanchang University, Nanchang
[2] State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou
来源
Liu, Ying (lying@ncu.edu.cn) | 2018年 / Shanghai Jiaotong University卷 / 52期
关键词
Corrosion resistance; Hemocompatibility; Interfacial tension; Passivation; Stainless steel;
D O I
10.16183/j.cnki.jsjtu.2018.05.014
中图分类号
学科分类号
摘要
In order to improve the corrosion resistance and hemocompatibility of 316L stainless steel, mechanical polished 316L stainless steel was modified in situ by mixed acid (2%HF+10%HNO3, volume fraction) immersion and high-temperature treatment. The surface morphologies of 316L stainless steel and modified 316L stainless steel were characterized by X-ray diffraction (XRD), atom force microscopy (AFM) and scanning electron microscope with energy dispersion spectrometer (SEM-EDS). The corrosion resistance and wettability of 316L stainless steel and modified 316L stainless steel were analyzed by electrochemical and contact angle measurement respectively. The results indicated that Cr-O oxidation films were formed on 316L stainless steel after mixed acid immersion. Fe2O3 and Cr-O mixed oxidation films were grown on the high-temperature treatment 316L stainless steel. The corrosion resistance of modified 316L stainless steel was improved in simulated body fluid. The surface of 316L stainless steel modified by the two methods was hydrophilic. The surface energy polarization component of mixed acid immersion and high-temperature treatment 316L stainless steel were all increased. While, the interfacial tension between the materials and blood was decreased. Mixed acid passivation and high-temperature treated can improve the corrosion resistance and hemocompatibility properties of 316L stainless steel. © 2018, Shanghai Jiao Tong University Press. All right reserved.
引用
收藏
页码:593 / 598
页数:5
相关论文
共 18 条
  • [1] Pourhashem S., Afshar A., Double layer bioglass-silica coatings on 316L stainless steel by sol-gel method, Ceramics International, 40, 1, pp. 993-1000, (2014)
  • [2] Talha M., Kumar S., Behera C.K., Et al., Effect of cold working on biocompatibility of Ni-free high nitrogen austenitic stainless steels using Dalton's Lymphoma cell line, Materials Science and Engineering C: Materials for Biological Applications, 35, 10, pp. 77-84, (2014)
  • [3] Kim M.S., Dean L.S., In-stent restenosis, Cardiovascular Therapeutics, 29, 3, pp. 190-198, (2011)
  • [4] Simsek Z., Koza Y., Tas M.H., Et al., Two cases of very late bare-metal stent thrombosis and literature review, European Review for Medical and Pharmacological Sciences, 18, 11, pp. 1674-1677, (2014)
  • [5] Chen Q., Thouas G.A., Metallic implant biomaterials, Materials Science and Engineering R: Reports, 87, 1, pp. 1-57, (2015)
  • [6] Koppara T., Sakakura K., Pacheco E., Et al., Preclinical evaluation of a novel polyphosphazene surface modified stent, International Journal of Cardiology, 222, pp. 217-225, (2016)
  • [7] Fu T., Wen C.S., Lu J., Et al., Sol-gel derived TiO<sub>2</sub> coating on plasma nitrided 316L stainless steel, Vacuum, 86, 9, pp. 1402-1407, (2012)
  • [8] Huang Q., Yang Y., Hu R., Et al., Reduced platelet adhesion and improved corrosion resistance of superhydrophobic TiO<sub>2</sub>-nanotube-coated 316L stainless steel, Colloids and Surfaces B: Biointerfaces, 125, pp. 134-141, (2015)
  • [9] Mohan C.C., Cherian A.M., Kurup S., Et al., Stable titania nanostructures on stainless steel coronary stent surface for enhanced corrosion resistance and endothelialization, Advanced Healthcare Materials, 6, 11, (2017)
  • [10] Liu Y., Liu X., Wang J., Et al., Corrosion resistance and hemocompatibility of zirconium oxide thin films prepared by sol-gel dip coating method, Journal of Functional Materials, 45, 14, pp. 14061-14065, (2014)