Influence of Inlet Vortex on Pressure Pulsation in Axial Flow Pump Unit

被引:0
|
作者
Song X. [1 ]
Liu C. [1 ]
Luo C. [1 ]
机构
[1] School of Hydraulic Energy and Power Engineering, Yangzhou University, Yangzhou
来源
Liu, Chao (liuchao@yzu.edu.cn) | 2018年 / Chinese Society of Agricultural Machinery卷 / 49期
关键词
Axial-flow pump; High speed camera; Pressure pulsation; Vortex;
D O I
10.6041/j.issn.1000-1298.2018.02.015
中图分类号
学科分类号
摘要
The pressure pulsation is one of the main causes of vibration and noise in axial flow pump, in order to study the mechanism of pressure fluctuation induced by vortex, several pressure pulsation monitoring points were stalled at the bottom of the pump sump, the horn mouth, the impeller inlet and outlet, the outlet of the guide vane. The flow rate of 1.2Qd (1.2Qd=38.4 L/s) was selected. The dynamic process of vortex generation and disappearance was measured by an advanced high-speed camera, and the microscopic variation of the vortex was observed. The results showed that the vortex tube below the horn position and low position, the maximum amplitude of pressure fluctuation at the bottom of the vortex tube, the Cp value was about 1.8~2 times of the non center point of pressure fluctuation of Cp value, at the center of tube, the pressure pulsation frequency of the vortex occurred at 1 time of the impeller rotation frequency. The pressure fluctuation at the impeller inlet and the pressure fluctuation at the impeller were synchronized at 1 time of the impeller frequency, and the pressure pulsation frequency was 1 time of the frequency of impeller. The detailed structure of the vortex changes was clearly observed by high-speed cameras. On the whole, the maximum amplitude of pressure fluctuation was at the inlet of impeller, and the maximum amplitude of pressure fluctuation occurred at the center of the vortex belt. The Cp value of the pressure fluctuation at the center of the vortex belt was about 1.8~2 times of the Cp value of the pressure fluctuation at the non center point. Getting through the water inlet swirl from generation to the collapse process and the influence of pressure fluctuation, can provide a theoretical basis for the pumping station project of vortex elimination measures. © 2018, Chinese Society of Agricultural Machinery. All right reserved.
引用
收藏
页码:113 / 119and81
相关论文
共 20 条
  • [1] Liu C., Researches and developments of axial-flow pump system, Transactions of the Chinese Society for Agricultural Machinery, 46, 6, pp. 49-59, (2015)
  • [2] He Y., Main advances of research on vortices in pump sumps, Journal of Hydroelectric Engineering, 23, 5, pp. 92-96, (2004)
  • [3] Shi W., Leng H., Zhang D., Et al., Performance prediction and experiment for pressure fluctuation of interior flow in axial-flow pump, Transactions of the Chinese Society for Agricultural Machinery, 42, 5, pp. 44-48, (2011)
  • [4] Liu C., Cheng L., Zhou J., Et al., Numerical simulation of three-dimensional turbulent flow for opening pump sump, Transactions of the Chinese Society for Agricultural Machinery, 33, 6, pp. 53-55, (2002)
  • [5] Cong G., Wang F., Applicability of turbulence models in numerical simulation of vortex flow in pump sump, Transactions of the CSAE, 24, 6, pp. 31-35, (2008)
  • [6] Yang F., Liu C., Tang F., Et al., Analysis of hydraulic performance for vertical axial-flow pumping system with cube-type inlet passage, Transactions of the CSAE, 30, 4, pp. 62-69, (2014)
  • [7] Cheng L., Liu C., Zhou J., Numerical simulation of flow in the outlet passages of reversible pumping station by RNG k-ε turbulent model with wall function law, Advances in Water Science, 15, 1, pp. 109-112, (2004)
  • [8] Song X., Liu C., Yang F., Et al., Experiment on characteristics of the pressure fluctuation at bottom of pumping suction passage, Transactions of the Chinese Society for Agricultural Machinery, 48, 11, pp. 196-203, (2017)
  • [9] Liu C., Liang H., Jin Y., Et al., PIV measurements of intake flow field in axial-flow pump, Transactions of the Chinese Society for Agricultural Machinery, 46, 8, pp. 33-41, (2015)
  • [10] Qiu B., Huang J., Lin H., Et al., Experimental investigation on flow fields in outlet divergent passage of vertical axial-flow-pump, Chinese Journal of Mechanical Engineering, 41, 11, pp. 115-126, (2005)