摘要
The PHC energy pile and traditional vertical ground heat exchanger have significant differences in heat exchanger structure, environmental sensitivity and heat transfer behavior. The long-term in-situ thermal response test of PHC energy pile in multi-layer strata was carried out at the energy pile testing site of Jiulonghu campus of Southeast University. The pile length is 24 m, and the heat exchange pipe is a single U-shape pipe. The duration of test reaches 1 100 h. The 20 m deep ground temperature borehole is set at 0.5, 0.65 and 1.15 m from the center of the energy pile to monitor the ground temperature. Field test combined with numerical simulation to analyze and study the heat transfer behavior of PHC energy pile in multi-layer strata and the influence of multi-layer strata on the heat transfer performance of energy pile. The research results show that: (1) At the beginning of heating, the closer the soil to the energy pile, the faster the temperature rises. After a long heating period, the amplitude and velocity of ground temperature rise of each soil layer have decreased. For instance, after heating for 760 h, the temperature rise rate of each point in the soil decreased by more than 80% compared with the first continuous heating. (2) When the thermal response power changes, the closer the soil is to the energy pile, the greater the temperature of the energy pile and the more sensitive the response. As the distance increases, the temperature influence becomes smaller. The soil temperature response has a delay effect, and the further away from the energy pile, the greater the delay. (3) At the soil layer with high thermal conductivity and thermal diffusivity, the ground temperature amplitude and velocity of the soil near the energy pile are both small. Conversely, at the soil layer with lower thermal conductivity, the soil temperature near the energy pile rises faster and rises at a greater speed. (4) After the TRT unit stopped heating, the ground temperature at all points decreased and recovered quickly in the vicinity, while in the distance, the ground temperature showed a first increasing and then decreasing trend due to the delay effect. (5) Numerical simulation results show that thermal conductivity and specific heat capacity produce different effects on soil heat transfer. The heat exchange of the energy pile increases when the soil thermal conductivity is higher. © 2020, Science Press. All right reserved.
引用
收藏
页码:3615 / 3626
页数:11
相关论文
共 33 条
  • [1] XIA Caichu, ZAHNG Guozhu, SUN Meng, Theory and application of energy geo-structure: ground source heat pump system with ground heat exchanger in geo-structure, pp. 3-4, (2015)
  • [2] Alice Di Donna, LALOUI Lyesse, DI DONNA Alice, Energy Geo-structure, pp. 2-6, (2016)
  • [3] XIA Caichu, CAO Shiding, WANG Wei, An introduction to energy geotechnical engineering, Chinese Journal of Underground Space and Engineering, 5, 3, pp. 419-424, (2009)
  • [4] BRANDL H., Energy foundations and other thermo-active ground structures, Geotechnique, 56, 2, pp. 81-122, (2006)
  • [5] RYOZO O., Investigation of a ground source heat pump system for use in large and dense city areas in Japan, IEA Heat Pump Centre Newsletter, 23, 4, pp. 33-35, (2005)
  • [6] HASSANI N G E, UOTINEN V M, KUJALA K., Numerical modeling of thermal regimes in steel energy pile foundations: A case study, Energy and Buildings, 69, pp. 165-174, (2014)
  • [7] MAN Y, YANG H X, DIAO N R, Et al., A new model and analytical solutions for borehole and pile ground heat exchangers[J], International Journal of Heat and Mass Transfer, 53, pp. 2593-2601, (2010)
  • [8] GAO J, ZHANG X, LIU J, Et al., Thermal performance and ground temperature of vertical pile-foundation heat exchangers: a case study, Applied Thermal Engineering, 28, 17, pp. 2295-2304, (2008)
  • [9] HAMADA Y, SAITOH H, NAKAMURA M, Et al., Field performance of an energy pile system for space heating, Energy and Buildings, 39, 5, pp. 517-524, (2007)
  • [10] ZHAO Jun, WU Ting, ZHU Qiang, Et al., Thermal simulation on the steady heat transfer of the U-pipe pile heat exchanger, Acta Energiae Solaris Sinica, 26, 1, pp. 59-62, (2005)