The Performance and Robustness of Power Protection Schemes for Grid-Connected PV Systems Under Varied Smart Inverter Controllers

被引:0
|
作者
Alasali, Feras [1 ]
El-Naily, Naser [2 ]
Loukil, Hassen [3 ]
El Deen Omran, Emad [4 ]
Holderbaum, William [5 ]
Elhaffar, Abdelsalam [6 ]
Saidi, Abdelaziz Salah [7 ]
机构
[1] Department of Electrical Engineering, Faculty of Engineering, The Hashemite University, P.O. Box 330127, Zarqa,13133, Jordan
[2] College of Electrical and Electronics Technology-Benghazi, Benghazi, Libya
[3] Department of Electrical Engineering, College of Engineering, King Khalid University, Abha,61421, Saudi Arabia
[4] Engineering Department, Suez Canal Authority, Ismailia, Egypt
[5] Science and Engineering, Manchester Metropolitan University, Manchester,M1 5GD, United Kingdom
[6] Department of Electrical Engineering, Sultan Qaboos University, Seeb, Oman
[7] National School of Engineers of Tunis, Electrical Systems Laboratory, University of Tunis El Manar, Tunis, Tunisia
关键词
Electric power system control - Electric power system protection - Relay control systems - Relay protection - Robustness (control systems) - Smart power grids;
D O I
10.1155/2024/6805410
中图分类号
学科分类号
摘要
The increasing use of inverter-based distributed generation requires a comprehensive study of its effects on fault analysis and the effectiveness of protection systems in distribution networks. This study examines the impact of different inverter control modes on multiple types of protective relay schemes. These include different overcurrent relay (OCR) schemes, both standard and nonstandard tripping characteristics, optimal coordination approaches, and different grid operation scenarios. The investigation is conducted through the utilization of grid-connected and islanding operation modes, with fault resistance values of 0 and 5 Ω. The study is carried out on a 14-bus CIGRE network which includes two photovoltaic (PV) farms with a capacity of 10 MVA each. The research provides several significant contributions, including the analysis of fault current contributions, examination of issues in OCR protection, investigation of the influence of fault impedance levels on OCR performance, evaluation of ideal coordination methods, and carrying out a comparative analysis utilizing optimization technique by using the water cycle optimization algorithm (WCA) and the particle swarm optimization algorithm (PSO). In addition, to guarantee the robustness of the suggested protection strategy, this work adopts a hardware-in-the-loop approach. The OMICRON-256 system is utilized to carry out real-time testing on a SIPROTEC 7SJ62 multifunction protection relay, which validates the effectiveness of the proposed method in protecting microgrids under different PV control strategies. The total operating time for the nonstandard tripping scheme was 12.077-12.3003 s for PSO and WCA, respectively, while for the standard tripping scheme, it was 12.1226 and 12.1564 s. Moreover, these findings offer practical insights that can assist operators in effectively designing the power networks with grid-connected PV systems by showing OCR miscoordination and no tripping events in power systems with PVs under inverters controllers. Copyright © 2024 Feras Alasali et al.
引用
收藏
相关论文
共 50 条
  • [1] Smart Grid Resilience for Grid-Connected PV and Protection Systems under Cyber Threats
    Alasali, Feras
    Itradat, Awni
    Abu Ghalyon, Salah
    Abudayyeh, Mohammad
    El-Naily, Naser
    Hayajneh, Ali M.
    Almajali, Anas
    [J]. SMART CITIES, 2024, 7 (01): : 51 - 77
  • [2] Inverter power sizing considerations in grid-connected PV systems
    Velasco, Guillermo
    Gulnjoan, Francesc
    Pique, Robert
    Conesa, Alfonso
    Negroni, J. J.
    [J]. 2007 EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-10, 2007, : 2310 - +
  • [3] An integrated inverter with maximum power tracking for grid-connected PV systems
    Ho, BMT
    Chung, HSH
    Hui, SYR
    [J]. APEC 2004: NINETEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1-3, 2004, : 1559 - 1565
  • [4] An integrated inverter with maximum power tracking for grid-connected PV systems
    Ho, BMT
    Chung, HSH
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (04) : 953 - 962
  • [5] MPPT Performance of a Grid-connected PV Inverter under Malaysian Conditions
    Azli, N. A.
    Salam, Z.
    Jusoh, A.
    Facta, M.
    Lim, B. C.
    Hossain, S.
    [J]. 2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 457 - +
  • [6] Research on the Control Method of the PV Grid-Connected Inverter under an Asymmetrical Power Grid Fault
    Tian, Shiji
    Lu, Min
    Wang, Ruikang
    Liu, Di'an
    [J]. ENERGIES, 2023, 16 (22)
  • [7] SMART INTEGRATION OF FUTURE GRID-CONNECTED PV SYSTEMS
    Azzopardi, B.
    Mutale, J.
    [J]. 2009 34TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE, VOLS 1-3, 2009, : 2412 - 2417
  • [8] Comparative Study Between PI and Resonant Controllers for PV Grid-Connected Inverter
    Makhloufi, S.
    [J]. INTERNATIONAL JOURNAL OF GRID AND DISTRIBUTED COMPUTING, 2014, 7 (03): : 135 - 142
  • [9] Operational Performance of Grid-Connected PV Systems
    Moraitis, Panagiotis
    van Sark, Wilfried G. J. H. M.
    [J]. 2014 IEEE 40TH PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2014, : 1953 - 1956
  • [10] Performance parameters for grid-connected PV systems
    Marion, B
    Adelstein, J
    Boyle, K
    Hayden, H
    Hammond, B
    Fletcher, T
    Canada, B
    Narang, D
    Kimber, A
    Mitchell, L
    Rich, G
    Townsend, T
    [J]. Conference Record of the Thirty-First IEEE Photovoltaic Specialists Conference - 2005, 2005, : 1601 - 1606