Biaxial Tensile Prestress and Waveguide Effects on Estimates of the Complex Shear Modulus Using Optical-Based Dynamic Elastography in Plate-Like Soft Tissue Phantoms

被引:1
|
作者
Dore, Marta [1 ]
Luna, Aime [1 ]
Royston, Thomas J. [1 ]
机构
[1] Richard and Loan Hill Department of Biomedical Engineering, University of Illinois Chicago, 851 South Morgan Street, MC 063, Chicago,IL,60607, United States
基金
美国国家科学基金会;
关键词
Biaxial tensile - Biological tissues - Complex shear modulus - Elastography - Optical- - Phantoms - Soft tissue phantoms - Tissue properties - Viscoelastic properties - Viscoelastics;
D O I
10.1115/1.4056103
中图分类号
学科分类号
摘要
Dynamic elastography attempts to reconstruct quantitative maps of the viscoelastic properties of biological tissue, properties altered by disease and injury, by noninvasively measuring mechanical wave motion in the tissue. Most reconstruction strategies that have been developed neglect boundary conditions, including quasi-static tensile or compressive loading resulting in a nonzero prestress. Significant prestress is inherent to the functional role of some biological tissues, such as skeletal and cardiac muscle, arterial walls, and the cornea. In the present article a novel configuration, inspired by corneal elastography but generalizable to other applications, is studied. A polymer phantom layer is statically elongated via an in-plane biaxial normal stress while the phantom's response to transverse vibratory excitation is measured. We examine the interplay between biaxial prestress and waveguide effects in this plate-like tissue phantom. Finite static deformations caused by prestressing coupled with waveguide effects lead to results that are predicted by a novel coordinate transformation approach previously used to simplify reconstruction of anisotropic properties. Here, the approach estimates material viscoelastic properties independent of the nonzero prestress conditions without requiring advanced knowledge of those stress conditions. Copyright © 2023 by ASME.
引用
收藏
相关论文
共 3 条
  • [1] Biaxial prestress and waveguide effects on estimates of the complex shear modulus using optical elastography in a transverse isotropic cornea phantom
    Dore, Marta
    Luna, Aime
    Sun, Michael
    Royston, Thomas
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [2] Decoupling Uniaxial Tensile Prestress and Waveguide Effects From Estimates of the Complex Shear Modulus in a Cylindrical Structure Using Transverse-Polarized Dynamic Elastography
    Salehabadi, Melika
    Crutison, Joseph
    Klatt, Dieter
    Royston, Thomas J.
    Journal of Engineering and Science in Medical Diagnostics and Therapy, 2023, 6 (02)
  • [3] Uniaxial prestress and waveguide effects on estimates of the complex shear modulus using magnetic resonance elastography in a transverse isotropic muscle phantom and excised muscle
    Salehabadi, Melika
    Crutison, Joseph
    Nammari, Lara
    Klatt, Dieter
    Royston, Thomas
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):