Performance analysis of the heat supply system with the waste heat recovery from the sterilization of the mushroom sticks

被引:0
|
作者
Wang, Lincheng [1 ,3 ]
Quan, Zhenhua [1 ]
Zhao, Yaohua [1 ,2 ]
Jing, Heran [1 ]
Ren, Haibo [1 ]
Du, Boyao [1 ]
机构
[1] Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing,100124, China
[2] Zibo Boienergy science and technology Co., Ltd., Zibo,255200, China
[3] School of Civil Engineering, Inner Mongolia University of Technology, Hohhot,010051, China
关键词
Agriculture - Carbon dioxide - Global warming - Investments - Steam - Steam condensers - Digital storage - Agricultural wastes - Air conditioning - Heating - Waste incineration - Sterilization (cleaning) - Waste heat utilization - Condensation - Heat exchangers - Nitrogen oxides;
D O I
暂无
中图分类号
学科分类号
摘要
Shiitake mushroom has been one of the most edible fungus varieties in China. However, a large amount of the waste heat has been discharged during the industrialized production and sterilization of mushroom sticks, as the cultivation scale develops rapidly in recent years. The waste heat has also posed a serious threat to environmental pollution, even disorderly spilling of exhausted steam condensate during the process. In this study, a new type of heat exchanger with a porous channel was designed for a mushroom production factory in Zibo City, Shandong Province, China. A waste heat recovery system was also proposed to apply for the exhaust steam and condensed water of the sterilization, where the engineering data was measured in practice. The results show that the waste heat in the heating season was used for the heating of cultivation sheds, office buildings, and dormitories in the factory. The temperature range of the water supply was 36-48 ℃, and the daily heat supply was between 8-18 GJ. In non-heating seasons, the waste heat was used for the secondary preheating of the water supply to a gas boiler, or the bathing water. The temperature range of the water supply was 65-75 ℃, and the daily heat supply was 8-10 GJ, where the total heat transfer coefficient of the heat exchanger was about 70-105 W/(m2•K). As such, the efficient recovery of the waste heat was achieved for the exhausted steam wastewater from mushroom sterilization over the entire year. It was estimated that the net saved cost was 194 000 Yuan, the initial investment can be recovered in about 3.1a. Reduce carbon dioxide emissions by 135.6 t/a, reduce sulfur dioxide emissions by 10.35 kg/a, reduce nitrogen dioxide emissions by 43.5 kg/a, and reduce smoke and dust emissions by 16.57 kg/a, reflecting better economic and environmental benefits. Small-scale agricultural waste heat recovery projects should try to use waste heat throughout the year to shorten the payback period. The hot water storage tank can be used in the design to realize the contradiction between the time mismatch between the waste heat and the heat supply. During the operation, attention should be paid to the operation mode of the heating system when the waste heat is insufficient and how to maximize the use of waste heat. The research methods and results of this project can provide references for the recovery and utilization of agricultural waste heat, and are of great significance for reducing energy consumption, reducing energy costs of shiitake mushrooms, reducing pollution emissions, and improving the ability of agricultural sustainable development. © 2022, Editorial Department of the Transactions of the Chinese Society of Agricultural Engineering. All right reserved.
引用
收藏
页码:248 / 257
相关论文
共 50 条
  • [1] Annual performance analysis of heat pump drying system with waste heat recovery
    Zhao Haibo
    Wu Kun
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 53
  • [2] Performance Analysis of an Absorption Heat Pump System for Waste Heat and Moisture Cascade Recovery from Flue Gas
    Li, Zongjin
    Xue, Shaoxin
    Hu, Dongzi
    Teng, Da
    Zhang, Shiping
    Shen, Guoqing
    [J]. ACS OMEGA, 2022, 7 (28): : 24596 - 24605
  • [3] Thermal performance analysis of heat pipe heat exchanger for effective waste heat recovery
    Geum, Gyohoon
    Kang, Sukkyung
    Cho, Sehyeon
    Kong, Daeyoung
    Lee, Seungjae
    Seo, JinHyeuk
    Shin, Dong Hwan
    Lee, Seong Hyuk
    Lee, Jungho
    Lee, Hyoungsoon
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2024, 151
  • [4] Effect of the heat exchanger in the waste heat recovery system on a gasoline engine performance
    Choi, Kyungwook
    Kim, Kibum
    Lee, Kihyung
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2015, 229 (04) : 506 - 517
  • [5] Cost performance optimization of waste heat recovery supply chain by mobile heat storage vehicles
    Yang, Jing
    Chen, Jiayu
    Zhang, Zhiyong
    Hong, Ming
    Li, Han
    Li, Yilong
    Yang, Mingwan
    [J]. ENERGY REPORTS, 2020, 6 : 137 - 146
  • [6] Optimum design and performance analysis of waste heat recovery system for biomass fermentation
    He, Wei
    Cao, Yongna
    Shang, Hongru
    Li, Yinxue
    Guo, Chao
    Yu, Yanling
    [J]. Huagong Xuebao/CIESC Journal, 2023, 74 (10): : 4302 - 4310
  • [7] Performance analysis of a waste heat recovery thermoelectric generation system for automotive application
    Liu, X.
    Deng, Y. D.
    Li, Z.
    Su, C. Q.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 90 : 121 - 127
  • [8] Performance analysis of a metal-hydride heat transformer for waste heat recovery
    Kang, BH
    Yabe, A
    [J]. APPLIED THERMAL ENGINEERING, 1996, 16 (8-9) : 677 - 690
  • [9] Analysis of a Waste Heat Recovery System for a Gas Engine
    Chen Bo
    Wang Genquan
    Zhang Limin
    Wang Xuan
    Liu Peng
    [J]. PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY AND MANAGEMENT SCIENCE (ITMS 2015), 2015, 34 : 993 - 998
  • [10] Waste of heat recovery in the industrial system with a heat pipe
    Królicki, Z
    Bialko, B
    Denys, M
    [J]. INZYNIERIA CHEMICZNA I PROCESOWA, 2004, 25 (04): : 2183 - 2190