Gas detection technology algorithm based on TDLAS

被引:0
|
作者
Jia J. [1 ]
Li W. [1 ]
Chai H. [1 ]
Zhang S. [1 ]
Zhang M. [1 ]
Cui H. [1 ]
Liu J. [1 ]
Liu Z. [1 ]
机构
[1] Beijing Orient Institute for Measurement and Test, Beijing
关键词
Gas detection; Harmonic signal; Numerical simulation; TDLAS;
D O I
10.3788/IRLA201948.0517007
中图分类号
学科分类号
摘要
Tunable diode laser absorption spectroscopy (TDLAS) is a high sensitive and high resolution gas absorption spectrum detection technology, with fast response, high precision, excellent single mode characteristics and strong versatility. The temperature and concentration of the detected gas were calculated by measuring the absolute absorption intensity in the direct absorption method of TDLAS, but was easily affected by particle concentration and fluctuation of laser intensity. The laser was modulated through high frequency sinusoidal signal in the wavelength modulation method of TDLAS, making the laser output frequency and intensity modulated simultaneously, with the characteristics of high signal-tonoise ratio and sensitivity, but the gas parameters were determined by calibration experiments or complex algorithms. Therefore, the expression of harmonic terms containing molecular absorption information was deduced through the theory of absorption spectrum and wavelength modulation, and the relationship between harmonic signal and absolute absorption intensity of detected gas was analysed, establishing the measurement algorithm of absolute absorption intensity based on harmonic signal. The absorption spectral line of NH3 molecule near 1 531 nm was taken as an example for numerical analysis, and the relative errors between theoretical calculation (a=0) and simulation values were no more than 2% when the modulation amplitude reached up to a=0.032 cm-1 (m=2), which further proved the reliability of on-line measurement algorithm. © 2019, Editorial Board of Journal of Infrared and Laser Engineering. All right reserved.
引用
收藏
相关论文
共 14 条
  • [1] Reid J., Labrie D., Second-harmonic detection with tunable diode lasers-Comparison of experiment and theory, Applied Physics B, 26, 3, pp. 203-210, (1981)
  • [2] Wang X., Liu S., CO<sub>2</sub> concentration measurement based on TDLAS, Control and Instruments in Chemical Industry, 43, 11, pp. 1158-1161, (2016)
  • [3] Yuan Z., Yang X., Xie W., Et al., Research on the online test of diesel NO<sub>x</sub> emission by TDLAS, Spectroscopy and Spectral Analysis, 38, 1, pp. 194-199, (2018)
  • [4] Li Z., Zhang Z., Sun P., Et al., Multi-point full range monitoring of methane based on TDLAS technology, Infrared and Laser Engineering, 46, 9, (2017)
  • [5] Xu L., Liu C., Jing W., Et al., Tunable diode laser absorption spectroscopy-based tomography system for on-line monitoring of two-dimensional distributions of temperature and H<sub>2</sub>O mole fraction, Review of Scientific Instruments, 87, (2016)
  • [6] Li M., Guo J., Ye W., Et al., Study on TDLAS system with a miniature multi-pass cavity for CO<sub>2</sub> measurements, Spectroscopy and Spectral Analysis, 38, 3, pp. 697-701, (2018)
  • [7] Liu J.T.C., Jeffries J.B., Hanson R.K., Wavelength modulation absorption spectroscopy with 2f detection using multiplexed diode lasers for rapid temperature measurements in gaseous flows, Applied Physics B, 78, pp. 503-511, (2004)
  • [8] Sun L., Yu H., Online multi-component gas concentration detection system based on TDLAS technology, Instrument Technique and Sensor, 3, pp. 73-77, (2017)
  • [9] He X., Pan Y., The development status and application research of TDLAS technology, Journal of Ezhou University, 24, 1, pp. 102-104, (2017)
  • [10] Farooq A., Jeffries J.B., Hanson R.K., Sensitive detection of temperature behind reflected shock waves using wavelength modulation spectroscopy of CO<sub>2</sub> near 2.7μm, Applied Physics B, 96, 1, pp. 161-173, (2009)