Study of the simple formula of DC surface potential in AC-DC interconnected large power system

被引:0
|
作者
Ren, Zhichao [1 ]
Xu, Jianguo [1 ,2 ]
Zhang, Yikun [1 ]
Zhen, Wei [3 ]
Wu, Guangning [1 ]
机构
[1] Southwest Jiaotong University, Chengdu 610031, China
[2] Shanxi Electric Power Research Institute, Taiyuan 030001, China
[3] Sichuan Electric Power Research Institute, Chengdu 610072, China
关键词
Grounding electrodes - Electric grounding - Bias voltage - HVDC power transmission - Voltage distribution measurement - DC transformers;
D O I
暂无
中图分类号
学科分类号
摘要
DC magnetic bias, caused by the current from the DC grounding electrode, threatens the safety of AC grid. At first, a simple and easy-to-use formula for calculating the DC surface potential was presented, which was based on typical three-layer soil structure. Secondly, in the verification, measured value of DC current of transformer neutral point was applied to decide the coefficient of the formula by editing nodal equation. Comparison of the calculated, simulation and measured value demonstrates high accuracy of the formula. Finally, DC current distribution in substations caused by DC grounding electrode was evaluated by predicting DC surface potential and step voltage in a HVDC with the formula mentioned above. Several substations were pointed out to take protective measures.
引用
收藏
页码:256 / 263
相关论文
共 50 条
  • [1] Analysis on coupling of large hydraulic turbine with AC-DC interconnected power system
    Tang, Fan
    Liu, Tianqi
    Li, Xingyuan
    Dianwang Jishu/Power System Technology, 2011, 35 (03): : 38 - 43
  • [3] Impact of AC-DC interconnected system on distance protection and countermeasure
    Fei, Bin
    Huang, Shaofeng
    Shen, Hongming
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2015, 35 (08): : 15 - 21
  • [4] Cascading Outage Preventive Control for Large-scale AC-DC Interconnected Power Grid
    Yao, Rui
    Zhang, Xuemin
    Huang, Shaowei
    Mei, Shengwei
    Zhang, Zhen'an
    Li, Xiaomeng
    Zhu, Quansheng
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [5] Study of AC-DC Converters with Isolated Transformers Applied to High Frequency AC-DC Power Conversion
    Xue, X. D.
    Mei, J.
    Raman, Raghu S.
    Liu, J. F.
    Cheng, K. W. E.
    2015 6TH INTERNATIONAL CONFERENCE ON POWER ELECTRONICS SYSTEMS AND APPLICATIONS (PESA), 2015,
  • [6] Optimal reactive power dispatch in a large power system with AC-DC and FACTS controllers
    Thukaram, D.
    Yesuratnam, G.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2008, 2 (01) : 71 - 81
  • [7] Research on Emergency Power Control of AC-DC Hybrid Power System with Flexible DC
    Shu H.
    Shao Z.
    Zhao W.
    Bao G.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (20): : 5590 - 5604
  • [8] Improving automatic generation control by HVDC link in a parallel AC-DC interconnected power system
    Dept. of Electrical and Electronic Engineering, Kumaraguru College of Technology, Coimbatore-680 006, India
    不详
    Adv Model Anal C, 2007, 3-4 (20-32): : 20 - 32
  • [9] A SIMPLE APPROACH TO THE SOLUTION OF THE AC-DC POWER FLOW PROBLEM
    TYLAVSKY, DJ
    IEEE TRANSACTIONS ON EDUCATION, 1984, 27 (01) : 31 - 40
  • [10] Optimal Allocation of AC-DC Capacity Considering Cascading Failure Risk of AC-DC Parallel Power System
    Tu, Jingzhe
    Lu, Zehan
    Song, Xiaozhe
    Liu, Yun
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,