Domestic hot water system combining solar and waste heat from thermoelectric air-conditioner

被引:3
|
作者
Khedari, J. [1 ]
Maneewan, S. [1 ]
Pratinthong, N. [1 ]
Chimchavee, W. [1 ]
Hirunlabh, J. [1 ]
机构
[1] Building Scientific Research Center, School of Energy and Materials, King Mongkut's Univ. Tech. Thonburi, Bangmod, Thungkru, Bangkok 10140, Thailand
关键词
Air conditioning - Cooling systems - Heat exchangers - Solar energy - Thermoelectric equipment - Waste heat utilization;
D O I
暂无
中图分类号
学科分类号
摘要
This paper investigates the performance of a new hybrid domestic hot water system that combines solar energy with waste heat from a thermoelectric (TE) air-conditioner. To this end, 30 TE modules model no. TEC1-12704 (module specifications: 40 x 40 mm, maximum operating voltage and current: 13.5 VDC and 4.4 Amp) were used. The collector/storage tank capacity was 120 litres. The volume of the testing room for cooling was 2.5 m3. Investigations were undertaken by varying the voltage to the thermoelectric module (50, 100, 150 VDC), water mass flow rate and air velocity passing through the TE heat exchangers: 10, 15 l/min and 2.5, 5 m/s, respectively. It was found that this system can heat up the 120 litres to 50°C within 2 hours. The cooling capacity was 176 W. After that, the cooling capacity decreased as a result of the increase of water temperature returned from the tank and circulated through TE water/solid heat exchanger. Finally, under design consideration used in this study, the optimum conditions for operating the hot water production and cooling as well are: 100 VDC, water flow rate of 15 l/min and air velocity at 2.5 m/s. The corresponding highest coefficient of performance of the hybrid system is about 3.12.
引用
收藏
页码:19 / 28
相关论文
共 50 条
  • [1] Experimental Research on Improvement of the Heat Pump Air-conditioner and Hot Water System
    Chen, Jianbo
    Li, Fen
    Min, Kuangwei
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 6199 - 6203
  • [2] The air-conditioner system with a kind of waste heat recovery unit
    Hu, XH
    Shu, SM
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 1063 - 1065
  • [3] Experimental research on the operational characteristics of household air-conditioner with domestic hot water supply
    Gao, Yanbing
    Huai, Lanlan
    Jin, Wen
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 677 - 682
  • [4] Hot Water Making Potential Using of a Conventional Air-Conditioner as an Air-Water Heat Pump
    Chaiwongsa, Praitoon
    Duangthongsuk, Weerapun
    2ND INTERNATIONAL SCIENCE, SOCIAL SCIENCE, ENGINEERING AND ENERGY CONFERENCE 2010 (I-SEEC 2010), 2011, 8 : 165 - 170
  • [5] Performance of a solar integrated heat pump air-conditioner, water heater and dryer
    Hawlader, M.N.A.
    Shaochun, Ye
    International Journal of Ambient Energy, 2008, 29 (04): : 189 - 196
  • [6] Performance of a solar integrated heat pump air-conditioner, water heater and dryer
    Hawlader, M. N. A.
    Shaochun, Ye
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2008, 29 (04) : 189 - 196
  • [7] Domestic air-conditioner and integrated water heater for subtropical climate
    Ji, J
    Chow, TT
    Pei, G
    Dong, J
    He, W
    APPLIED THERMAL ENGINEERING, 2003, 23 (05) : 581 - 592
  • [8] Experimental Study of Energy-Saving Air-Conditioner with Hot Water
    CHEN Jian-bo
    CHEN Dan
    LU Ying(University of Shanghai for Science and Technology
    Shanghai
    China)
    湖南大学学报(自然科学版), 2009, 36(S1) (自然科学版) : 75 - 78
  • [9] Experimental investigations on the thermal performance of a domestic condensing heat recovery air-conditioner
    Qiu, Fuqiang
    Li, Baoguo
    Xu, Taoping
    ADVANCES IN MECHANICAL ENGINEERING, 2019, 11 (02)
  • [10] Experimental study of energy-saving air-conditioner with hot water
    Chen, Jian-Bo
    Chen, Dan
    Lu, Ying
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2009, 36 (SUPPL.): : 75 - 78