Imaging Property of Inverse Geometry Micro-CT with Micro Multi-focus X-ray Source Based on Electron Beam Scanning

被引:0
|
作者
Zhou, Rifeng [1 ,2 ,3 ]
Tang, Jie [1 ,2 ]
Hu, Xiaolong [1 ,2 ]
Xie, Dongyang [1 ,2 ]
Liu, Yuchuan [1 ,2 ]
机构
[1] Engineering Research Center of Industrial CT Nondestructive Testing of Ministry of Education, Chongqing,400044, China
[2] ICT Research Center, Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing,400044, China
[3] State Key Laboratory of Mechanical Transmission, Chongqing University, Chongqing,400044, China
关键词
Electron sources - Electron beams - Iterative methods - Geometry - Computerized tomography - Signal to noise ratio - Scanning - Inverse problems - Redundancy - X ray detectors;
D O I
暂无
中图分类号
学科分类号
摘要
In theory, inverse geometry CT has the advantages of larger scanning field, higher signal-to-noise ratio and fewer cone beam artifacts. However, in the multi-focus and sparse angle scanning mode, the projection data also has some problems such as data truncation, sparseness and local redundancy. An inverse geometry Micro-CT experimental system (IG-Micro-CT) with high resolution and large field of view was constructed by using electron beam scanning array micro multi-focal X-ray source and small area high-resolution detector. In view of the characteristics of multi-focal, sparse angle scanning mode projection data truncation and sparseness, a relative prior image guided SART iterative CT image reconstruction algorithm was proposed. Firstly, the algorithm was verified by simulation experiments, and the scanning parameters such as the number of ray source focus were optimized. Finally, high-resolution Micro-CT test images were obtained on the IG-Micro-CT experimental system. The experimental results show that the proposed algorithm can solve the problems of strip and truncation artifacts caused by projection data truncation, sparse sampling and local data redundancy. Besides, the feasibility of this new imaging method of IG-Micro-CT was verified, which lays a foundation for the practical application of IG-Micro-CT system. © 2021, Editorial Board of Atomic Energy Science and Technology. All right reserved.
引用
收藏
页码:2374 / 2381
相关论文
共 50 条
  • [1] Imaging of metallic foams using X-ray micro-CT
    Saadatfar, M.
    Garcia-Moreno, F.
    Hutzler, S.
    Sheppard, A. P.
    Knackstedt, M. A.
    Banhart, J.
    Weaire, D.
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2009, 344 (1-3) : 107 - 112
  • [2] A Novel Micro-Multifocus X-Ray Source Based on Electron Beam Scanning for Multi-View Stationary Micro Computed Tomography
    An, Kang
    Yin, Yifan
    Li, Fukun
    Shi, Limin
    Hu, Xiaolong
    Tang, Jie
    Zhou, Rifeng
    IEEE ELECTRON DEVICE LETTERS, 2020, 41 (01) : 167 - 170
  • [3] Micro-CT system for small animal imaging with ultrafast laser-based x-ray source
    Krol, A
    Kieffer, JC
    Chen, L
    Toth, R
    Coman, LL
    Lipson, ED
    Kincaid, RE
    Chamberlain, CC
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 1516 - 1519
  • [4] Respiratory-gated micro-CT using a carbon nanotube based micro-focus field emission x-ray source
    Cao, Guohua
    Lee, Yueh Z.
    Liu, Zejian
    Rajaram, Ramya
    Peng, Rui
    Calderon-Colon, Xiomara
    An, Lei
    Wang, Peng
    Phan, Tuyen
    Lalush, David
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [5] Desktop x-ray micro-CT instruments
    Sasov, A
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 282 - 290
  • [6] High Throughput Micro-CT Scanner Using a Distributed Multi-Beam Field Emission X-Ray Source
    Peng, R.
    Zhang, J.
    Calderon-Colon, X.
    Quan, E.
    Wang, S.
    Sultana, S.
    Chang, S.
    Lalush, D.
    Lu, J.
    Zhou, O.
    MEDICAL PHYSICS, 2009, 36 (06) : 2513 - +
  • [7] Mean absorbed dose to mouse in micro-CT imaging with an ultrafast laser-based x-ray source
    Krol, Andrzej
    Ye, Hongwei
    Kincaid, Russell
    Boone, John
    Servol, Marina
    Kieffer, Jean-Claude
    Nesterets, Yakov
    Gureyev, Tim
    Stevenson, Andrew
    Wilkins, Steve
    Lipson, Edward
    Toth, Remy
    Pogany, Andrew
    Coman, Ioana
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [8] Time-optimized X-ray micro-CT imaging of polymer based scaffolds
    Morris, David E.
    Mather, Melissa L.
    Simon, Carl G., Jr.
    Crowe, John A.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2012, 100B (02) : 360 - 367
  • [9] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [10] Phase contrast imaging using a micro focus x-ray source
    Zhou, Wei
    Majidi, Keivan
    Brankov, Jovan G.
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IX, 2014, 9207