Seismic response analysis of complex subway station structure with unequal-span in liquefiable foundation

被引:0
|
作者
Wang J. [1 ,2 ]
Fu J. [3 ]
Zhuang H. [3 ]
Dou Y. [1 ]
Ma G. [1 ]
机构
[1] School of Civil and Transportation Engineering, Hebei University of Technology, Tianjin
[2] China National Machinery Industry Co., Ltd., Beijing
[3] Institute of Geotechnical Engineering, Nanjing Tech University, Nanjing
来源
关键词
Sand liquefaction; Seismic performance; Seismic response; Subway station; Unequal-span underground structure;
D O I
10.13465/j.cnki.jvs.2020.07.024
中图分类号
学科分类号
摘要
Foundation liquefaction is one of the important causes for serious damage of subway underground station structure in earthquake. However,there is a little research on the seismic response of subway underground station structure in liquefiable sites at present. The research on the seismic response of large and complex underground station structures with unequal spans is even more rare. In this paper, by introducing the large deformation constitutive model of sand liquefaction and using the finite element mesh adaptive adjustment technique to overcome the distortion of soil mesh large deformation, a finite element numerical model of static and dynamic coupling nonlinear interaction between liquefied site soil and complex unequal span subway station structure was established. The distribution characteristics of site liquefaction, floating characteristics of unequal-span station structure, displacement settlement and vector characteristics of surrounding site, lateral deformation and seismic damage characteristics of the interaction system were analyzed. The seismic response law of the interaction system and the seismic failure characteristics of large-scale unequal-span underground structures in liquefied foundation were preliminarily revealed. The research results help to improve the understanding of the seismic response of unequal-span subway station structures in liquefied sites and the seismic design methods. © 2020, Editorial Office of Journal of Vibration and Shock. All right reserved.
引用
收藏
页码:170 / 179
页数:9
相关论文
共 28 条
  • [1] Long H., Chen G., Zhuang H., Effective stress analysis of seismic response characteristics of metro station structure in liquefiable foundation, Rock and Soil Mechanics, 34, 6, pp. 1731-1737, (2013)
  • [2] Iai S., Matsunaga Y., Morita T., Et al., Effects of remedial measures against liquefaction at 1993 Kushiro-Oki Earthquake, (1994)
  • [3] Koseki J., Matsuo O., Sasaki T., Et al., Damage to sewer pipes during the 1993 Kushiro-Okiand and the 1994 Hokkai-do-Toho-Oki earthquake, Soils and Foundations, 40, 1, pp. 99-111, (2000)
  • [4] Huo H., Bobet A., Fernandez G., Et al., Load transfer mechanisms between underground structure and surrounding ground: evaluation of the failure of the Daikai Station, Journal of Geotechnical and Geoenvironmental Engineering, 131, 12, pp. 1522-1533, (2005)
  • [5] Chen G., Chen S., Du X., Et al., Review of seismic damage, model test, available design and analysis methods of urban underground structures: retrospect and prospect, Journal of Disaster Prevention and Mitigation Engineering, 36, 1, pp. 1-23, (2016)
  • [6] Du X., Li Y., Xu C., Et al., Review on damage causes and disaster mechanism of Daikai subway station during 1995 Osaka-Kobe Earthquake, Chinese Journal of Geotechnical Engineering, 40, 2, pp. 223-236, (2018)
  • [7] Wang G., Zhang J., Wei X., Seismic response analysis of a subway station in liquefiable soil, Chinese Journal of Geotechnical Engineering, 33, 10, pp. 1623-1627, (2011)
  • [8] Liu H.B., Song E.X., Seismic response of large underground structures in liquefiable soils subjected to horizontal and vertical earthquake excitations, Computers and Geotechnics, 32, pp. 223-244, (2005)
  • [9] Liu C., Tao L., Bian J., Et al., Research on seismic response of the soft and underground structure caused by liquefiable soil in different positions, Journal of Hunan University (Natural Sciences), 44, 5, pp. 143-156, (2017)
  • [10] Cui C., Cheng X., Sun Z., Et al., Analysis of seismic response and parametric sensitivity of subway station surrounded by saturated soft soil, Journal of Railway Engineering Society, 34, 3, pp. 92-98, (2017)