A study on fundamental frequency of cold-formed thin-walled steel-gypsum based self-leveling mortar composite floor

被引:0
|
作者
Guan Y. [1 ]
Shi Y. [2 ]
Gao L. [1 ]
机构
[1] Chang'an University, School of Civil Engineering, Xi'an
[2] Key Laboratory of New Technology for Construction of Cities in Mountain Area(Chongqing University), Ministry of Education, Chongqing
来源
Shi, Yu | 2018年 / Chinese Vibration Engineering Society卷 / 37期
关键词
Cold-formed steel; Composite floor; Experimental study; Fundamental frequency; Gypsum based self-leveling mortar;
D O I
10.13465/j.cnki.jvs.2018.20.032
中图分类号
学科分类号
摘要
Two full scale models of cold-formed thin-walled steel-gypsum based self-leveling mortar composite floor were carried out for vibration test under four dynamic loadings which included walking along and transverse to the floor joist, walking along the diagonal direction of floor and hammer impact. The effects to the natural frequency of composite floors were studied when steel mesh was installed. The study showed that the natural frequency of composite floor did not change greatly with the change of external excitation. It did not significantly increase the natural frequency of composite floor via installing steel mesh into the gypsum based self-leveling mortar. The ABAQUS finite element software was used to conduct modal analysis of test models as well as variable parameter analysis based on the calibrated model. The research shows that fundamental frequency of cold-formed thin-walled steel composite floor can be improved by increasing plate thickness of floor joist and reducing floor span. The change of floor slab thickness and floor width along with strengthening flat strap and blocking brings little effect to the fundamental frequency of cold-formed thin-walled steel composite floor. Based on parameter analysis, composite floor can be equivalent to a simply supported beam with uniform quality and stiffness for computing the fundamental frequency of cold-formed thin-walled steel composite floor. © 2018, Editorial Office of Journal of Vibration and Shock. All right reserved.
引用
收藏
页码:207 / 215
页数:8
相关论文
共 7 条
  • [1] Parnell R.A., Davis B.W., Xu L., Vibration performance of lightweight cold-formed steel floors, Journal of Structural Engineering, 136, 6, pp. 645-653, (2010)
  • [2] Xu L., Floor vibration in lightweight cold-formed steel framing, Advances in Structural Engineering, 14, 4, pp. 659-672, (2011)
  • [3] Jia Z., Zhou X., Experimental study of vibration behavior of cold-formed steel concrete composite floor, China Civil Engineering Journal, 44, 4, pp. 42-51, (2011)
  • [4] Steel Design Guide Series 11-Floor Vibrations due to Human Activity, (1997)
  • [5] Design of structures for earthquake resistance: BS EN 1998-1-2004, (2005)
  • [6] Zhou X., Gao T., Shi Y., Experimental study on static deflection and vibration behavior of cold-formed steel OSB composite floor, Engineering Mechanics, 31, 5, pp. 211-217, (2014)
  • [7] Jia Z., Zhou X., Study on fundamental frequency of cold-formed steel concrete floor, Engineering Mechanics, 27, 11, pp. 144-153, (2011)